You are on page 1of 2
FP @ LABORATO' Certificate No. Reg. No. Date of Issue Date of Received Date of calibration RY CERTIFICATE OF CALIBRATION NSF/LB1/C/22-1-82 Sticker No. : NSF/LB1/R/22-12-6 + 18 January 2022 42 January 2022, 14 January 2022 Page 1 of 2 Dus date + 14 January 2023 (Requested by customer) “Tro er shoul be aware Wat ny number oats may causes Insrumer'o if ol of caltatonbelore te specied Cattrateneiervainas expres Customer + Sclence-Tech Solution Sdn Bhd ‘A-1-5 Block/A Megan Ave, 1 89, Jalan Tun Razak Hampshire Park 50450,Kuala Lumpur Attention + Mr Mohd Haigal Hakimi Telephone 0197382961 Fax - ‘Adjustable Torque Wrench sition Manufacturer : King Toyo ‘On visually checked found naa esta instrument in good condition Serial no. 498745 When returned: Calibrated and Serviceable Method of calibration NSF/Lab/CPIMS-04(180:6789 - Hend Torque Too!s) Calibration standards Description SeralNa Due Dale Gerficale No Tracaabi Siandara Weight io/ales77 | 12 February 2022 PPSB/16-00487 PSB Standard Weight wwiales7s | 12 February 2022 PPSB/18-00488 PPSB Thermotygrograpn | -AEH421503.62 | 4 February 2022 | — SSTIWN/R/2020B/65 SIRIM SST ‘Ambient Conditions. + Lab, Calibration Temperature (232 3) °C Rolative Humility (60215) %RH ‘Approved Signatories ja Aziz Bin Raja Omar oO Mohd Fairoz Bin Mohd Yusot [7 NSF ENGINEERING SDN. BHD. (Laboratory) PLO 819 AVB, Jalan Platinum 4, Tot +607-256776113, Platinum Business Park, Fax +607-2557764/5, kawasan Perindustian Pasir Gudang, Zon 128, Website wiw.nsfesb com 81700 Pasir Gudang, Johor. Emall nsflab@nsfesb com ‘Copyright of scariest cnred by ta Weung barter and May Tot be Tapradoced cher Than Tul wrap WA Te pO Write AppIOVT aT Hen tHe ang laboratory, cremestine nonehe LABORATORY CERTIFICATE OF CALIBRATION Certificate No. 2 NSFILB1/C/22-1-82 Page 2 of 2 Date of calibration 14 January 2022 Device Under Calibration + Adjustable Torque Wrench Manufacturer : King Toyo Model no. F300 Serial no. 438745 CALIBRATION RESULT ‘The result of the readings are given in following table Calibration range : 600 to 3000 Ft CALIBRATED ‘APPLIED Clock Wise Anti-Clock Wise umiTs Fel Fe Feb Fb, uur Stanndard Value | Correction | Standard Value | Correction 50.0 27.0 230 : a NA. 180.0 128.0 22.0 : : NA 300.0 273.0 27.0 : : NA. Note () LUT = Unit Under Test (i) Correction = Standard Value - UUT cana - SA eae Reiaee ia eer erate Ce eet co ean ree same eee Tisai Ceres eaters een rie ieee are ‘Conia of tis arate onied bythe eeu abOTTeny and Tay Fol ba reproduced eter han Tn ull cep wah The por wien approval ot iead of he esuinglanoratory

You might also like