You are on page 1of 1

1 2 3 4 5 6

Note :-
Drawing is based on the received drawings
and input from client, equipment/chamber
A 12
location may be vary as per actual site A
3.26 condition.
BOOTH

200W

13
10
9
AVC CE
EN P

TRAFFIC DIRECTION
S
E O
LOOP PR LO

17 11
7 1
3

BOOTH

B 200W
B
6
2

5
E
AVC E NC 16
15 LOOP ES OP
PR LO

8 TRAFFIC DIRECTION
LANE EQUIPMENT DETAILS
LANE
CLOSED TRAFFIC CONE
C C

℄ PAY AXIS LEGEND LEGEND:


CONCRETE BLOCKS S.No. DESCRIPTION
DIMENSIONS
Ref DWG.
P.V.C CONDUITS Ø
32.5 MM FOR POWER
MM
P.V.C CONDUITS Ø
LANE INCIDENT & ANPR
32.5 MM FOR DATA
1 CAMERA POLE 300x300x300 6PD0005

NOTES:- 2
FOUNDATION

BARRIER GATE
FOUNDATION
500x500x500 6PD0002
CONDUIT Ø 63 MM

HEIGHT SENSOR
POLE FOUNDATION

1. Thermoplastic marking and traffic cones are in client scope. 3


CANOPY POLE
FOUNDATION
----------------------- ---------------------- CAMERA POLE
FOUNDATION

2. For all sensors, loops, further road cutting / digging & foundation work are in client scope and 4
TRAFFIC LIGHT, UFD &
V.LIGHT POLE 300x300x300 6PD0003
PRESENCE LOOP

D shall happen under the supervision of engineers.


FOUNDATION
AVC LOOP D
5 AXLE IR SENSOR FRAME ----------------- -----------------

3. Separate Conduit for data & power shall be provided. CHAMBER

TRAFFIC LIGHT, UFD &


CONDUIT FOR PRESENCE
4. Conduits for connectivity between Booth to Booth and Booth to Plaza shall be finalized by client. 6
LOOP
----------------- ----------------- VIOLATION LIGHT POLE
FOUNDATION
LANE INCIDENT & LPIC
CAMERA POLE
7 CHAMBER 450x450x450 ----------------- FOUNDATION

FOR LANE:- 8 PAY AXIS 1000 -----------------


CONDUIT Ø 65 MM FOR
CHAMBER TO CHAMBER
CONNECTIVITY
LED LIGHT 200W.

1. Barrier Gate & all other pole foundations shall be 25mm above median surface. 9 AVC LOOP (Normal Lane) 2500x1000 -----------------
200W (FOCUS ON PRESENCE
LOOP)
RFID READER (TO BE
2. Proper earthing to be provided in each booth/tunnel for barrier gates, same is in client scope . PRESENCE LOOP (Normal
MOUNTED ON CANOPY)

10 2500x1000 -----------------
3. Loop groove shall be of 60mm depth. Lane) TRAFFIC CONE
SHALL BE ON CLIENT
SCOPE
11 BOOTH 3500x1900 -----------------

RECOMMENDATIONS:- 12 3D PROFILER FOUNDATION 300x300X300 -----------------

E 1. It is proposed that no iron Re-bar or dowels should be used below AVC Sensor Area. 13 LIGHT 200 WATT ----------------------- ----------------------
E
2. Distance from Pay axis is measurement base point for all equipments.
14 RFID READER
3. Dimensions are in Metre (unless otherwise specified).
4. Please follow written dimensions only. 15 AVC LOOP (Extrawide Lane) 3000x1000 -----------------

5. Earthing Required less then 2 ohm for all equipments including ( Barrier gate,Traffic 16
PRESENCE LOOP
(Extrawide Lane) 3000x1000 -----------------

light) & TLC cabinet. 17


BARRIER SAFETY
300X300X300
FOUNDATION

TITLE: EQUIPMENT CIVIL LAYOUT REV. DATE DOCUMENT HISTORY


EQUIPMENT CIVIL LAYOUT
PROJECT :- PLAZA :- CLIENT :-
F DRAWN BY: CHECKED BY: APPROVED BY:
F
Supply, Installation Commissioning, Technical Support, Management & Chenab Toll Plaza_South Bound M/s Sh. Iqbal Akhtar & CO.
Maintenance of Automatic Vehicle Classification Based Electronic Toll & SKS SA VS
NOT TO SCALE
Traffic Management System on National Highways N-5 package - II
1 23.01.2020 IR BARRIER SAFETY SENSOR POLE DIMENSION IN:
SIZE: A3 DWG. NO.: NHA-TM115802D101-S
FOUNDATION ADDED METER
0 15.01.2020 INITIAL RELEASE CAD FILE : SHEET: 3 OF 3

1 2 3 4 5 6