Automatic cavity pressure relief is provided to relieve the trapped fluid into the internal pipeline, when the ball valve is closed with the fluid trapped in the body cavity and the pressure of the trapped fluid goes up abnormally as the unstable factor. Automatic cavity pressure relief is also called self-relieving
seat in a ball valve.
When the valve is closed, the fluid is trapped in the body cavity of a ball valve. As an unstable factor, such as the rise in temperature, the trapped pressure will rise abnormally. It is harmful to the pipeline and may lead to serious risks.
As specified by API 6D, the body cavity pressure shall not exceed 1.33 times the valve pressure rating at the specified maximum operating temperature.
The trunnion-mounted ball valve also traps the media in the body cavity when the operator closes the valve. The pressure in the body cavity increases when heated and pushes the downstream ball valve seat away from the ball by rising pressure against the spring load. When this happens, the pressure gets
released.
There are two ways of making cavity relief for floating ball valves.
1. Make a hole through the body cavity to access the valve port (bypass), so the body cavity and the port are at the same pressure condition when the valve is fully closed.
2. In the case of increased temperature, valve position is "full open" and fluid pressurizing direction "1-way".
1). Make a relief groove on the upstream side of the ball seat.
2). Cut a hole in the ball face on the upstream side of the port pass.
Cavity relief testing can be performed to detect liquids or other fluids with thermal capacity trapped in the body cavity. Cavity relief testing is recommended where the medium is subject to heating or big differences in temperature between day and night with the potential generation of overpressure in the
body cavity with potential hazard for the whole system.
B.8.1 Frequency Each valve shall be tested. Cavity relief testing is not required if protection of the cavity against over-pressure is ensured, for both the open and the closed position, by a hole in the obturator or around the seat seal.
B.8.2 Trunnion-mounted ball valves and through-conduit gate valves with internal relieving seats
The following is the procedure for cavity-relief testing of trunnion-mounted ball valves and through-conduit gate valves with internal-relieving seats.
Fill the valve in the half-open position with water. Close the valve and allow water to overflow from the test connection at each end of the valve. Apply pressure to the valve cavity until one seat relieves the cavity pressure into the valve end; record this pressure relief.
For valve types with second-seat relief, continue to increase the pressure to the cavity until the second seat relieves; record the relief pressure of the second seat. Failure to relieve at a pressure less than 1,33 times the valve pressure rating shall be cause for rejection.
With the valve half-open, pressurize the valve to 1,33 times the valve pressure rating specified in 7.2 for the material at 38 °C (100 °F).
b) Close the valve and allow each end to return to atmospheric pressure.
c) Open the valve to the half-open position and monitor for the release of test medium trapped in the cavity. The presence of trapped pressurizing medium in the cavity is grounds for rejection.
Related Product:
8 inch ball valve, 26 inch ball valve, 28 inch ball valve, 30 inch ball valve
Online Inquiry
* Name
* Email
Telephone
Company
* Inquiry Content
Send Message
Top Products
RELATED NEWS
Seat, seal, and gasket material selection guide for ball valves, including application fluid, temperature range, and pressure range, etc....
Dec 28, 2023
Valve material and application: casting valve material and forged valve material, including carbon steel, low temperature carbon steel, alloy steel, stainless steel, bron...
Dec 28, 2023
API 600 trim number chart for trim parts stem, back seat, disc/wedge, seat surface of gate, globe and check valves. API 600 valve trim for a range from trim no. 1 to 18....
About
As an export-oriented valve manufacturer and supplier, Relia Valve focus on manufacturing valves for overseas market. 100% of the ball valves are hydro tested as API standard and customer request before leaving the factory.
Recommend Products
Ball Valve
Gate Globe Check
Support
About
Contact
Contact Us
WhatsApp
8613634229454
Email
info@reliavalve.com
Inquiry
TOP
Online Inquiry
* Name
* Email
Telephone
Company
* Inquiry Content
Send Message