Builder Top Vent

Direct Vent
Models: 33LDVT, 36LDVT
39LDVT, 43LDVT

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY


Installation and service must be
performed by a qualified installer,
service agency or the gas supplier. Installation Instructions and
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
Homeowner’s Manual
����
• Do not touch any electric switch; do
not use any phone in your building. ����������
• Immediately call your gas supplier DE S I GN� ����
from your neighbor’s phone. Follow
the gas suppliers instructions.
• If you cannot reach your gas
supplier call the fire department. CE
RTIFIED
CERTIFIED

DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
10007852 5/07 Rev. 9

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Table of Contents
PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE.
Thank you and congratulations on your purchase of a CFM Corporation fireplace.
IMPORTANT: Read all instructions and warnings carefully before starting installation.
Failure to follow these instructions may result in a possible fire hazard and will void the warranty.

Installation & Operating Instructions


Important Curing/Burning Instructions ................................................................................. 3
Fireplace Dimensions .......................................................................................................... 4
Locating Your Fireplace ....................................................................................................... 5
Clearance to Combustibles ................................................................................................. 5
Mantels ............................................................................................................................... 5
Hearth ............................................................................................................................... 6
Framing & Finishing ............................................................................................................ 6
Final Finishing ..................................................................................................................... 6
Gas Specifications............................................................................................................... 6
Gas Inlet and Manifold Pressures ....................................................................................... 6
High Elevations ................................................................................................................... 7
Gas Line Installation ............................................................................................................ 7
Remote Switch Installation .................................................................................................. 7
Alternate Switch Location .................................................................................................... 7
EB-1 Electrical Box.............................................................................................................. 8
Electronic Gas Control Valve .............................................................................................. 8
General Venting Information
General Venting Information-Termination Location .......................................................... 10
General Information on Assembling Vent Pipes ................................................................ 11
How to Use the Vent Graph............................................................................................... 12
Vertical Sidewall Applications & Installation ...................................................................... 12
Below Grade Installations.................................................................................................. 16
Vertical Through-the-Roof Applications & Installations ...................................................... 17
Venting Components ......................................................................................................... 20
Operating Instructions
Glass Information .............................................................................................................. 21
Louvre Removal ................................................................................................................ 21
Window Frame Assembly Removal................................................................................... 21
Glass Cleaning .................................................................................................................. 21
Installation of Logs, Lava Rock & Ember Material ............................................................ 22
Flame & Temperature Adjustment ..................................................................................... 24
Flame Characteristics........................................................................................................ 24
Lighting & Operating Instructions ...................................................................................... 26
Troubleshooting ................................................................................................................. 28
Fuel Conversion Instructions ............................................................................................. 30
Maintenance
Cleaning the Standing Pilot Control System ..................................................................... 31
Replacement Parts ...................................................................................................................... 32
Optional Accessories
Fan Kits ............................................................................................................................. 35
Wiring Instructions ............................................................................................................. 36
Ceramic Refractory Kits .................................................................................................... 36
Remote Controls ............................................................................................................... 36
Optional Trim Kits .............................................................................................................. 37
Screen Door Kits ............................................................................................................... 37
Filigree Louvre Kit ............................................................................................................. 37
Warranty ....................................................................................................................................... 39
Energuide ..................................................................................................................................... 40

2 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Installation & Operating Instructions


This gas fireplace should be installed by a qualified must be installed on a metal or wood panel extending the
installer, preferably NFI or WETT (Canada) certified, in full width and depth of the fireplace.
accordance with local building codes and with current CSA- 12. This fireplace requires adequate ventilation and combustion
B149.1 Installation codes for Gas Burning Appliances and air to operate properly.
Equipment. For USA Installations follow local codes and/or 13. This fireplace must not be connected to a chimney flue
the current National Fuel Gas Code. ANSI Z223.1/NFPA 54. serving a separate solid fuel burning fireplace.
14. When the fireplace is not in use it is recommended that the
In the Commonwealth of Massachusetts, all gas fitting
gas control valve be left in the OFF position.
and installation of this heater shall only be done by a
15. These units have been approved for bedroom use.
licensed gas fitter or licensed plumber.
FOR SAFE INSTALLATION AND OPERATION PLEASE
NOTE THE FOLLOWING:
33LDVT / 36LDVT / 39LDVT / 43LDVT
1. This fireplace gives off high temperatures and should be Certified To
located out of high traffic areas and away from furniture and ANSI Z21.88-2005 / CSA 2.33-2005
draperies. Vented Gas Fireplace Heaters
2. Children and adults should be alerted to the hazards of the
high surface temperatures of this fireplace and should stay WARNING: Check with your electronics manufacturer
away to avoid burns or ignition of clothing.
before installing a television or other electronic de-
3. CAUTION: Due to high glass surface temperature chil-
vice above this fireplace.
dren should be carefully supervised when in the same
room as fireplace. This appliance may be installed in an aftermarket

�������
permanently located, manufactured home or mobile home,
� where not prohibited by local codes.
This appliance is only for use with the type of gas indicated
�������������� on the rating plate. This appliance is not convertible for
������������ use with other gases, unless a certified kit is used.
The LDVT has been approved for mobile home
������������������ installations.
�������������
�������������������� IMPORTANT:
��������������� PLEASE REVIEW THE FOLLOWING CAREFULLY

4. Under no circumstances should this fireplace be modified. Remove any plastic from from parts before turning the
Parts removed for servicing should be replaced prior to fireplace ON.
operating this fireplace again. It is normal for fireplaces fabricated of steel to give off
5. Installation and any repairs to this fireplace must be per- some expansion and/or contraction noises during the
formed by a qualified installer, service agency or gas sup- start up or cool down cycle. Similar noises are found
plier. A professional service person should be contacted to with your furnace heat exchanger or car engine.
inspect the fireplace annually. More frequent cleaning may It is not unusual for your gas fireplace to give off some
be required due to excess lint and dust from carpeting, bed-
odor the first time it is burned. This is due to the curing
ding material, etc.
6. Control compartments, burners and air passages in this fire-
of the paint and any undetected oil from the manufac-
place should be kept clean and free of dust and lint. Make turing process.
sure that the gas valve and pilot light are turned off before Please ensure that your room is well ventilated-open
you attempt to clean this fireplace. all windows.
7. The venting system (chimney) of this fireplace should be It is recommended that you burn your fireplace for at least
checked at least once a year and if needed your venting ten (10) hours the first time you use it. If the optional fan
system should be cleaned. kit has been installed, place the fan switch in the “OFF”
8. Keep the area around your fireplace clear of combustible position during this time.
materials, gasoline and other flammable vapour and liquids.
This fireplace should not be used as a dry-ing rack for cloth-
ing, nor should Christmas stockings or decorations be hung Proposition 65 Warning: Fuels used in gas, wood-
on or around the fireplace. burning or oil fired appliances, and the products of
9. Under no circumstances should any solid fuels (wood, coal, combustion of such fuels, contain chemicals known to
paper or cardboard etc.) be used in this fireplace.
the State of California to cause cancer, birth defects
10. The flow of combustion and ventilation air must not be ob-
structed in any way. and other reproductive harm.
11. When the fireplace is installed directly on carpeting, vinyl tile California Health & Safety Code Sec. 25249.6
or any combustible material other than wood, this fireplace

10007852 3

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Fireplace Dimensions
Rough E
Opening
Depth
S
R I

U V - Rough Opening Width


S
Rough
T Opening
Height

Low
Voltage
Access Electrical
Q Access
G B C D
Gas Line Low
Voltage
Access Electrical
Access

M N
O J
A
P Gas Line K
Access L
Fig. 1 Fireplace specifications and framing dimensions.

Ref. 33LDVT 36LDVT 39LDVT 43LDVT


A 33” (838 mm) 36” (914 mm) 39” (991 mm) 43” (1092 mm)
B 28⁷⁄₈” (733 mm) 34¹⁄₄” (870 mm) 34¹⁄₄” (870 mm) 37” (940 mm)
C 31¹⁄₄” (794 mm) 34¹⁄₄” (870 mm) 37¹⁄₄” (946 mm) 41¹⁄₄” (1048 mm)
D 18³⁄₈” (466 mm) 23” (584 mm) 23” (584 mm) 25³⁄₄” (654 mm)
E 22³⁄₄” (578 mm) 24” (610 mm) 27” (686 mm) 31” (788 mm)
F 14” (356 mm) 16” (406 mm) 16” (406 mm) 16” (406 mm)
G 31³⁄₄” (806 mm) 37” (939 mm) 37” (939 mm) 39³⁄₄” (1010 mm)
H -- -- -- -- -- -- -- --
I 6” (152 mm) 6³⁄₄” (170 mm) 6³⁄₄” (170 mm) 6³⁄₄” (170 mm)
J 4⁵⁄₈” (118 mm) 5⁵⁄₈” (143 mm) 5⁵⁄₈” (143 mm) 5⁵⁄₈” (143 mm)
K 6³⁄₈” (162 mm) 8” (203 mm) 8” (202 mm) 8” (203 mm)
L 8⁷⁄₈” (225 mm) 11⁷⁄₈” (302 mm) 11⁷⁄₈” (302 mm) 11⁷⁄₈” (302 mm)
M 2” (51 mm) 2” (51 mm) 2” (51 mmj) 2” (51 mm)
N 3³⁄₈” (86 mm) 3¹⁄₄” (83 mm) 3¹⁄₄” (83 mm) 3¹⁄₄” (83 mm)
O 4⁵⁄₈” (118 mm) 6³⁄₄” (172 mm) 6³⁄₄” (172 mm) 6³⁄₄” (172 mm)
P 6³⁄₈” (162 mm) 9¹⁄₄” (235 mm) 9¹⁄₄” (235 mm) 9¹⁄₄” (235 mm)
Framing Dimensions
Q 29⁵⁄₈” (753 mm) 35” (889 mm) 35” (889 mm) 37³⁄₄” (959 mm)
R 14¹⁄₂” (368 mm) 16¹⁄₂” (419 mm) 16¹⁄₂” (419 mm) 16¹⁄₂” (419 mm)
S 35³⁄₄” (908 mm) 39³⁄₄” (1010 mm) 43¹⁄₈” (1095 mm) 44¹⁄₈” (1121 mm)
T 50¹⁄₂” (1238 mm) 55¹⁄₄” (1403 mm) 60⁷⁄₈” (1546 mm) 62³⁄₈” (1584 mm)
U 25¹⁄₄” (641 mm) 28¹⁄₈” (714 mm) 30⁷⁄₈” (784 mm) 31¹⁄₄” (794 mm)
V 33¹⁄₂” (851 mm) 36¹⁄₂” (927 mm) 39¹⁄₂” (1003 mm) 43¹⁄₂” (1105 mm)

4 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Locating Your Fireplace V

Y
E A B
Y Z

X
C

D
Y A B C D E
X B
Fireplace
F
Top Louvre
Assembly

Fig. 2 Locate gas fireplace. LU584-T Top of


Locating unit Combustion
A - Flat on wall B - Cross corner C - 12/18/02
**Islanddjt CFM146 Chamber
D - *Room divider E - *Flat on wall corner F - Chase installation
Y - 6” minimum
Note (Fig. 2):
Mantel Chart
** Island (C) and Room Divider (D) installation is possible as Mantel Shelf CFM146 Mantel from Top
long as the horizontal portion of the vent system (X) does not Ref. or Breast Plate Ref.DV Mantel Chart
of Combustion Chamber
7/5/01 sta
exceed 20’ (6m). See details in manual Venting Section. Depth 36/39/43 LDVT 33LDVT
* When you install your fireplace in(D) Room divider or (E) V 10” (254 mm) A 17” (432 mm) 16¹⁄₂” (419 mm)
Flat on wall corner positions (Y), a minimum of 6” (152mm) W 8” (203 mm) B 15” (381 mm) 14¹⁄₂” (368 mm)
clearance must be maintained from the perpendicular wall and X 6” (152 mm) C 13” (330 mm) 12¹⁄₂” (318 mm)
the front side edge of the fireplace. See (Y) in Fig. 2. Y 4” (101 mm) D 11” (279 mm) 10¹⁄₂” (267 mm)
Z 2” (51 mm) E 9” (229 mm) 8¹⁄₂” (216 mm)
Clearance to Combustibles Fig. 3a Combustible mantel minimum installation.

Top of Unit to Ceiling ................................ 36” (914mm)


Appliance
Top ........................................................... 0” (0mm)
Bottom ...................................................... 0” (0mm)
Side .......................................................... 0” (0mm)
Back ......................................................... 0” (0mm)
Venting J
I
Black H
Concentric sections of DV Vent Surround G
Top, bottom & sides ............................... 1” (25mm) Face F
Mantel
Leg
Mantels
K
L
The height that a combustible mantel is fitted above the Side of M
Combustion Chamber N
fireplace is dependent on the depth of the mantel. This CFM164a O
Mantel Leg Chart
also applies to the distance between the mantel leg (if 06/22/01 sta
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 3a and 3b.
The fitting of a bay window trim kit does not effect
the distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
CFM170
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent Mantel Mantel Leg FromSide
discoloration. Ref. Leg Depth Ref. of Comb. Opening
F 10” (254 mm)
CFM170
K 11¹⁄₂” (292 mm)
G 8” (203 mm) L
DV Builder Front 9¹⁄₂” (241 mm)
H View
6” (152 mm) M 7¹⁄₂” (191 mm)
I 4” (101 mm) N 5¹⁄₂” (140 mm)
J 2” (51 mm) O 3¹⁄₂” (89 mm)
Fig. 3b Combustible mantel leg minimum installation.
10007852 5

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Hearth Gas Specifications


A hearth is not mandatory but is recommended for Max. Min. Air
aesthetic purposes. We recommend a noncombustible Gas Input Input Shutter
hearth which projects out 12” (305mm) or more from the Model Fuel Control BTU/h BTU/h Adj.
front of the fireplace. 33LDVTRN Nat Millivolt 16,000 11,200 3/16”
Open
Cold climate installation recommendation: 33LDVTRP Prop Millivolt 16,000 12,000 Fully Open
When installing this unit against a non- 33LDVTEN Nat 24V 16,000 11,200 3/16”
insulated exterior wall or chase, it is Hi/Lo Open
mandatory that the outer walls be insulated 33LDVTEP Prop* 24V 16,000 12,000 Fully Open
to conform to applicable insulation codes. Hi/Lo
36LDVTRN Nat Millivolt 19,500 13,650 Top &
Framing and Finishing Bottom
Hole Half
Check fireplace to make sure it is levelled Closed
and properly positioned. 36LDVTRP Prop Millivolt 19,500 14,625 Fully Open
36LDVTEN Nat 24V 19,500 13,650 Top &
Hi/Lo Bottom
To mount the appliance: Hole Half
1. Choose the location. Closed
2. This unit comes with four (4) flanges pre-mounted 36LDVTEP Prop* 24V 19,500 14,625 Fully Open
Hi/Lo
on both sides of the fireplace to allow two different
39LDVTRN Nat Millivolt 23,000 16,100 Top &
drywall thicknesses to be used. Flange “A” is for
Bottom
1/2” drywall while flange “B” is for 5/8” drywall. Hole Half
3. Bend the desired flanges out 90° on both sides of Closed
the fireplace. Slide the fireplace into the framed 39LDVTRP Prop* Millivolt 22,500 16,875 Fully Open
opening until the flanges contact the front surfaces 39LDVTEN Nat 24V 23,000 16,100 Top &
of the framing. Level the unit and secure it firmly in Hi/Lo Bottom
place. Hole Half
Closed
Flange Location for Desired Drywall Depth 39LDVTEP Prop* 24V 22,500 16,875 Fully Open
Flange Drywall 43LDVTRN Nat Millivolt 26,000 18,200 Top &
Position Depth Bottom
A 1/2” / 13 mm Hole Half
B 5/8” / 16 mm Closed
43LDVTRP Prop* Millivolt 24,000 18,000 Fully Open
43LDVTEN Nat 24V 26,000 18,200 Top &
Hi/Lo Bottom
Hole Half
A B
Closed
43LDVTEP Prop* 24V 24,000 18,000 Fully Open
Hi/Lo
*Using conversion kit

Gas Inlet and Manifold Pressures


FP1546
Fig . 4 Nailing flanges. Natural LP (Propane)
Inlet Minimum 5.5” w.c. 11.0” w.c.
Final Finishing
Inlet Maximum 14.0” w.c. 14.0” w.c.
Noncombustible materials suchFP1546
as brick or tile may be Manifold Pressure 3.5” w.c. 10.0” w.c.
LDVT nailing flanges
extended over the edges of the 1/05
face of the appliance.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the appliance.

6 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

High Elevations The fireplace valve must not be subjected to any test
pressures exceeding 1/2 psi. Isolate or disconnect this
Input ratings are shown in BTU per hour and are or any other gas appliance control from the gas line
certified without deration for elevations up to when pressure testing.
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, Remote ON/OFF Switch
installations must be in accordance with the cur- Installation:
rent ANSI Z223.1/NFPA 54 and/or local codes hav-
ing jurisdiction. 1. Thread the wiring through holes on the end panels
of appliance. Take care not to cut wire or insulation
In Canada, please consult provincial and/or local on metal edges. Route the wire to a conveniently
authorities having jurisdiction for installations at located receptacle box.
elevations above 4,500 feet (1,370m).
2. Attach the wire to the ON/OFF switch and install the
switch into the receptacle box.
Gas Line Installation
3. Connect the other ends of the wire to the gas control
When purging gas line, the front window valve. (Fig. 6)
frame removed. Remote ON/OFF
Switch or Thermostat or
Remote Control
The gas pipeline can be brought in through the rear
of the fireplace as well as the bottom. Knockouts are
provided on the bottom behind the valve to allow for the
gas pipe installation and testing of any gas connection.
It is most convenient to bring the gas line in from the TP
rear right side of the valve as this allows fan installation TH
Gas
or removal without disconnecting the gas line. Control
TP Valve
The gas line connection can be made with properly
tinned 3/8” copper tubing, 3/8” rigid pipe or an approved
flex connector. Since some municipalities have ad- TH
ditional local codes, it is always best to con- sult your
FP1224
local authority and the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 in the USA or the CSA-B149.1 installa- Fig. 6 Remote switch wiring diagram.
tion codes.
Alternate Switch Location
FP1224
1/2” Gas Supply
The remote switch canRemote
be installed on the front/side of
switch
1/2” NPT X 1/2” Flare Shut-off Valve the access door. Simply mount the switch to the bracket
11/02
provided and screw the bracket to either side of the
3/8” Flex line
frame, lining up the screws with the pre-punched holes.
(from valve)
(Fig. 7)

FP297A

Fig. 5 Typical gas supply installation.


Always check for gas leaks with a mild
soap and waterFP297A
solution. Do not use an
open flame for INSTA VENT FREE
leak testing.
UVHB26 GAS SUPPLY
The gas control is equipped7/1/98
with a captured screw type
pressure test point, therefore it is not necessary to pro-
vide a 1/8” test point up stream of the control. FP1024

When using copper or flex connector use only approved Fig. 7 Alternate switch location.
fittings. Always provide a union when using black iron
Do not wire the remote ON/OFF wall switch
pipe so that the gas line can be easily disconnected for
for the gas fireplace to the 120 volt power
burner or fan servicing . See gas specifications for pres- supply.
sure details and ratings.
10007852 7
FP1024
alternate
Downloaded from www.Manualslib.com manuals search engine
LDVT Series Direct Vent Gas Fireplace

INSIDE
EB-1 Electrical Box Electrical Box
Retaining Screw
The fireplace, when installed, must be elec-
trically connected and grounded in accord- ������
������

ance with local codes or, in the absence


of local codes, with the current CSA C22.1
Canadian Electrical Code. OUTSIDE

For USA installations follow local codes


and the national electrical code ANSI/
NFPA No. 70.
NIT
OF U
It is strongly suggested that the wiring of BAC
K

the EB-1 Electrical Junction Box be carried FP580

out by a licensed electrician. Fig. 8 EB-1 receptacle.


Ensure that the power to the supply line FP580
Electronic Gas Control Valve
INSTA VENT FREE
has been disconnected before commenc- EB1 JUNCTION BOX

ing this procedure. This appliance may be fitted11/18/97


with a Synetek ignition
module.
The EB-1 Electrical junction box has been fitted stand-
ard on this model to allow for the easy connection of an Installation of the remote on/off switch or wall ther-
optional fan kit. mostat on electronic ignition units.
To connect the EB-1 box to the house electrical supply 1. Thread the wiring through the holes on the side
follow the steps below. panels of the appliance. Take care not to cut the wire
1. Unscrew retaining screw from EB-1 base plate (Fig. or insulation on metal edges. Route the wire to a
8) and remove the EB-1 assembly from the appli- conveniently located receptacle box.
ance. 2. Attach the wire to the ON/OFF switch and install the
2. Remove the front cover of the EB box. switch into the receptacle box.
3. Remove the plug socket assembly from the EB-1 3. Connect the white wire from the wall switch or wall
box. thermostat to the white wire terminal from the elec-
4. Feed the supply line in through the EB-1 opening in tronic module. Connect the black wire from the wall
the side of the appliance and then through the back
switch or the red wire from the wall thermostat, to
of the EB-1 assembly. (Fig. 8)
the red wire terminal from the electronic module.
5. Connect the black wire of the power supply line to
the brass screw (polarized) of the socket assembly.
6. Connect the white wire of the power line to the
chrome screw of the socket assembly.
7. Connect the ground wire of the supply line to the
green screw of the socket assembly.
8. Refit the socket assembly back into the electrical
box and replace the cover plate. Secure the cable
with the clamp on the outside of the EB-1 base
plate and refit the EB-1 assembly to the unit with the
screw removed in step 1.

8 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

BLACK L1
WHITE L2
POWER CORD
GREEN

PURPLE
PILOT SENSING
PILOT IGNITER
YELLOW

M P
O O

VALVE
CIRCUIT BOARD
BLUE
ORANGE
RED ON/OFF SWITCH
WHITE OR
WALL THERMOSTAT

FP1571

Fig. 9 SIT822 Valve with Synetek electronic control wiring diagram.

General Venting
FP1571
Your fireplace is approved to be vented either through There must not be any obstruction such as bushes,
the side wall, or vertically through the roof. SIT822 garden sheds, fences, decks or utility buildings within
24” (610 mm) from the front of the termination hood.
• Only CFM Corporation venting componentsSynetek
spe- wiring
cifically approved and labelled for this fireplace
4/05 Do not locate termination hood where excessive snow
may be used. or ice build up may occur. Be sure to check vent termi-
nation area after snow falls, and clear to prevent ac-
• Vent terminations shall not be recessed into a wall cidental blockage of venting system. When using snow
or siding. blowers, make sure snow is not directed towards vent
• Horizontal venting which incorporates the twist lock termination area.
pipe must be installed on a level plane without an Location of Vent Termination
inclining or declining slope.
It is imperative the vent termination be located observ-
• Horizontal venting which incorporates the use of flex ing the minimum clearances as shown on the next
venting shall have an inclining slope from the unit of page.
1” (25 mm) per 24” (610 mm).
*Check with local codes or in absence of same with
CSA-B149.1 Installation Codes (1991) for Canada
or follow the current National Fuel Gas Code, ANSI
Z223.1/NFPA 54 for installations in the USA.

10007852 9

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

General Venting Information - Termination Location


INSIDE
CORNER DETAIL
G
V
H N
A N
D
E
V
L C B
B V �����
B V
������
V Fixed
Ope Operable
rable Closed
F V
B
B V X M
B J
I V K X
CFM145a A

V VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED

Canadian Installations1 US Installations2


CFM145a
A = Clearance above grade, veranda, porch, 12” (30cm)
DV Termin Location 12” (30cm)
deck, or balcony 5/01/01 Rev. 12/05/01
sta
B = Clearance to window or door that may be 6” (15cm) for appliances 6” (15cm) for appliances
opened < 10,000Btuh (3kW), 12” (30cm) < 10,000 Btuh (3kW), 9”
for appliances > 10,000 Btuh (3kW) and (23cm) for appliances > 10,000
< 100,000 Btuh (30kW), 36” (91cm) Btuh (3kW) and < 50,000 Btuh
for appliances > 100,000 Btuh (30kW) (15kW), 12” (30cm) for
appliances > 50,000 Btuh (15kW)
C = Clearance to permanently closed window 12” (305mm) recommended to 12” (305mm) recommended to
prevent window condensation prevent window condensation
D = Vertical clearance to ventilated soffit located
above the terminal within a horizontal 18” (458mm) 18” (458mm)
distance of 2’ (610mm) from the center
line of the terminal
E = Clearance to unventilated soffit 12” (305mm) 12” (305mm)
F = Clearance to outside corner see next page see next page
G = Clearance to inside corner (see next page) see next page see next page
H = Clearance to each inside of center line 3’ (91cm) within a height of 15’ (5m) 3’ (91cm) within a height of 15’
extended above meter/regulator assembly above the meter/regulator assembly (5m) above the meter/regulator
assy
I = Clearance to service regulator vent outlet 3’ (91cm) 3’ (91cm)
J = Clearance to nonmechanical air supply inlet 6” (15cm) for appliances < 10,000 6” (15cm) for appliances
to building or the combustion air inlet to any Btuh (3kW), 12” (30cm) for < 10,000 Btuh (3kW), 9”
other appliances appliances > 10,000 Btuh (3kW) and (23cm) for appliances > 10,000
< 100,000 Btuh (30kW), 36” (91cm) Btuh (3kW) and < 50,000 Btuh
for appliances > 100,000 Btuh (30kW) (15kW), 12” (30cm) for
appliances > 50,000 Btuh (15kW)
K = Clearance to a mechanical air supply inlet 6’ (1.83m) 3’ (91cm) above if within 10
feet (3m) horizontally
L = Clearance above paved sidewalk or paved 7’ (2.13m)† 7’ (2.13m)†
driveway located on public property
M = Clearance under veranda, porch, deck or 12” (30cm)‡ 12” (30cm)‡
balcony
N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof
surface, and any other obstruction within a horizontal distance of 18” (450mm).
1 In accordance with the current CSA-B149 Installation Codes
2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes
† A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and
serves both dwellings
‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor:
NOTE: 1. Local codes or regulations may require different clearances.
2. The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and
approved by the listing agency.
3. CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not
meet these requirements.
Fig. 10 Vent termination locations.
10 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner Outside Corner Alcove Applications*
D
C C
F=
G= Combustible
Combustible 6" (152 mm) V
G
6" (152 mm) Noncombustible
V
2" (51 mm) E
Noncombustible O
V 2" (51 mm) F

Balcony - Balcony -
with no side wall with perpendicular side wall
E = Min. 6” (152 mm) for
non-vinyl sidewalls
Min. 12” (305 mm) for
vinyl sidewalls
O = 8’ (2.4 m) Min.

M M No.
of Caps DMin. CMax.
V V
1 3’ (914 mm) 2 x DActual
P 2 6’ (1.8 m) 1 x DActual
Combustible & 3 9’ (2.7 m) 2/3 x DActual
M= Noncombustible 4 12’ (3.7 m) 1/2 x DActual
Combustible &
Noncombustible M = 24" (610 mm)
DMin. = # of Termination caps x 3
12" (305 mm) P = 20” (508 mm)
CMax. = (2 / # termination caps) x DActual 584-15
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All
mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All
gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.
Fig. 10a Termination clearances.

General Information on Assembling Vent Pipes


Canadian Installations: * Be sure the vent is actually crushed before proceed-
The venting system must be installed in accordance ing. Apply a tug to be sure the vent will not slip off the
with the current CSA-B149 .1 installation code. collars.
USA Installations: Repeat process with 7” flex vent pipe. The same proce-
The venting system must conform with local codes and/ dure must be performed on the vent side.
or the current National Fuel Gas code ANSI Z223.1/
NFPA 54.
Only venting components manufactured by CFM Cor-
poration can be used in Direct Vent systems.
Hose Clamp
Flex Vent Pipes Apply High Temperature
Sealant
Before joining the flex vent pipe to the unit, apply a
bead of high temperature sealant* (provided) to the 4”
pipe exiting the fireplace. Secure flex vent pipe in place
with a hose clamp (provided).
*Be sure the flex pipe overlaps at least 1” (25 mm) onto FP1471

the collars of the fireplace and termination. If the ter- Fig. 11 Apply high temperature sealant to 4” and 7” pipes.
mination has an internal bead, be sure to overlap and
secure 1” (25 mm) past the bead.

10007852 11

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Twist Lock Pipes


30
When using CFM Corporation twist-lock pipe it is not
29
necessary to use sealant on the joints. The only areas 28

Vertical dimension from the floor of the fireplace to


of the venting system that need to be sealed with high 27
temperature silicone sealant are the sliding joints of any 26
25
telescopic vent section used in the system.

the center of the horizontal vent pipe


24
To join the twist lock pipes together, simply align the 23
beads of the male end with the grooves of the female 22

end, then while bringing the ends together, twist the 21


20
pipe until the flange on the female end contacts the 19
external flange on the male end. It is recommended that 18
you secure the joints with three (3) sheet metal screws, 17
however this is not mandatory with twist lock pipe. 16
15
To make it easier to assemble the joints we suggest 14
putting a lubricant (Vaseline or similar) on the male end 13
of the twist lock pipe prior to assembly. 12 eg: A
11
10
Male End Female End 9
8
7
eg: B
6
5
4
3

Screw Holes TWL100 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Fig. 12 Twist-lock pipe joints. Horizontal dimension from the outside face of the wall to
the center of the fireplace vent flange
How to Use the Vent Graph CFM102
Sidewall vent graph showing the relationship between vertical
DV Graphic
and horizontal dimensions for a Direct Vent flue system.
The vent chart should be read in conjunction with the
TWL100 9/28/00 sta
following vent installation instructions
Twist Lock Pipe to determine the Fig. 13 Sidewall venting graph. (Dimensions in feet)
3/12/99and
relationship of the vertical djt horizontal dimensions of
Vertical Sidewall Applications
the vent system.
1. Determine the height of the center of the horizontal Since it is very important that the vent-
vent pipe exiting through the outer wall. Using this ing system maintain its balance between
dimension on the Sidewall Vent Graph. (Fig. 13) the combustion air intake and the flue
locate the point intersecting with the slanted graph gas exhaust, certain limitations as to vent
line. configurations apply and must be strictly
2. From the point of this intersection, draw a vertical adhered to.
line to the bottom of the graph. The vent graph showing the relationship between verti-
3. Select the indicated dimension, and position the cal and horizontal side wall venting will help to deter-
fireplace in accordance with same. mine the various dimensions allowable.

Example A: Minimum clearance between vent pipes


If the vertical dimension from the floor of the fireplace and combustible materials is one 1”
is 11’ (3.4 m) the horizontal run to the face of the outer (25mm) on top, bottom and sides unless
wall must not exceed 14’ (4.3 m). otherwise noted.

Example B: When the vent termination exits through foundations


If the vertical dimension from the floor of the unit is 7’ less than 20” (508mm) below siding outcrop, the vent
(2.14 m), the horizontal run to the face of the outer wall pipe must flush up with the siding.
must not exceed 8¹⁄₂’ (2.6 m). It is always best to locate the fireplace in such a way
that minimizes the number of offsets and horizontal
vent length of vent pipe from the flue collar of the fire-
place to the face of the outer wall.

12 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

20' (6m)

A
B
Pipe
7.5' (2.3m)

Straps Every
3’ (914mm)
Pipe Straps 7.5' 1 x 90° elbow in horizontal plane = 3’ (914mm)
Every 3’ (914mm) (2.3m)

Firestop/Zero A + B = 17' (5.2m) Max.


Clearance Sleeve
FP1012

Fig. 14 Support straps for horizontal runs. FP1238


Horizontal plane means FP1012
no vertical rise exists on this
Top vent max run Fig. 16 Maximum vent run with elbows.
portion of the vent assembly.
1/25/00 djt • The maximum number of 45° elbows permitted per
• The maximum number of 90° elbows per side wall side wall installation is two (2). These elbows can be
installations is three (3). installed in either the vertical or horizontal run.
• If a 90° elbow is fitted directly onto the fireplace • For each 45° elbow installed in the horizontal run,
flange the maximum horizontal vent run before the the length of the horizontal run MUST be reduced by
termination or a vertical rise is 36” (914mm). 18” (457 mm). This does not apply if the 45° elbows
• If a 90° elbow is used in the horizontal vent run are installed on the vertical part of the vent system.
(level height maintained) the maximum horizontal • The maximum number of elbow degrees in a system
vent length is reduced by 36” (914mm). This does is 270°. (Fig. 17)
not apply if the 90° elbows are used to increase or
redirect a vertical rise.
Example:
Example: According to the chart the maximum Elbow 1 = 90°
horizontal vent length in a system with a 7.5’ (2.3 m) Elbow 2 = 45°
vertical rise is 20’ (6m) and if a 90° is required in the Elbow 3 = 45° 4
horizontal vent it must be reduced to 17’ (5.2 m). Elbow 4 = 90°
In Figure 16, Dimension A plus B must not be
Total angular variation = 270°
greater than 17’ (5.2 m).

3'
(914mm)
1 + 2 + 3 + 4 = 270°
3
2
1

FP1237
FP1239
Fig. 15 Maximum horizontal vent run.
Fig. 17 Maximum number of elbow degrees.

FP1237
horizontal plane
12/02

10007852 13

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Vertical Sidewall Installation Adjustable Max. Length


12” (305mm)
Twist Lock Pipe Zero Clearance
Sleeve
STEP 1 #8 Screws (2)
Locate vent opening on the wall. It may be necessary
#8 Screws
to first position the fireplace and measure to obtain hole (2)
location. Depending on whether the wall is combustible #8 Screws
or noncombustible, cut opening to size. (Fig. 18) (2)
For combustible walls first frame in opening.
Firestop
NOTE: When using flex vent, the opening will have to
be measured according to the 1/2” (13 mm) rise in 12”
(305 mm) vent run. Adjustable Zero Clearance Sleeve ZCS101
Combustible Walls: (Fig. 18) Cut a 9³⁄₈”H x 9³⁄₈”W (240 Fig. 19 AdjustableZCS101
zero clearance sleeve.
x 240 mm) hole through the exterior wall and frame as Zero Clearance Sleeve
3/11/99 djt
shown.
Noncombustible Walls: (Fig. 18) Hole opening must
be 7¹⁄₂” (190 mm) in diameter.

Vent Opening for Combustible Wall


9³⁄₈” X
(240mm)

Framing
9³⁄₈” Detail
(240mm)

FP1240

Fireplace Hearth Fig. 20 Vertical height requirement.


Opening for Noncombustible Wall STEP 4
Attach the appropriate venting component(s) to the
7¹⁄₂” inner and outer flue collars of the fireplace using three
(190mm)
VO584-100
(3) screws. (Fig. 21) Follow with the installation of the
inner and outer elbow. Again secure joints with three (3)
Fig. 18 Locate vent opening on wall. sheet metal screws.
STEP 2
Measure wall thickness and cut zero clearance sleeve X
parts to proper length (MAXIMUM 12”/305 mm). As-
semble sleeve and attach to firestop with #8 sheet
metal screws (supplied). Install firestop assembly. (Fig.
19) VO584-100
Vent
Zero clearance Opening
sleeve is only required for
combustible walls.
2/99 djt
STEP 3
Place fireplace into position. (Fig. 20) Measure the ver-
tical height (X) required from the base of the flue collars
to the center of the wall opening.

FP1241

Fig. 21 Horizontal length requirement.

14 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

STEP 5
Measure the horizontal length requirement including
a 2” (51 mm) overlap, ie from the elbow to the outside
wall face plus 2” (51 mm) (or the distance required if
installing a second 90° elbow). (Fig. 21)
Always install horizontal venting on a level
plane.

STEP 6
Use appropriate length of pipe sections - telescopic or
fixed - and install the horizontal vent sections. The sec-
tions which go through the wall are packaged with the
starter kit, and can be cut to suit if necessary. (Fig. 22)
Sealing vent pipe and firestop gaps with
FP1243
high temperature sealant will restrict cold
air being drawn in around fireplace. Fig. 23 Apply high temperature sealant to collars or termina-
tions.
Support horizontal pipes every 3’ (914 mm) with metal
pipe straps. Make sure the horizontal vent pipe is in-
stalled on a level horizontal plane.

Vertical Sidewall Installation


Flex Vent Pipe
NOTE: The 40” (1016 mm) flex vent is used for 90° off
the top of the unit then out the back wall.
Follow Step 1 and 2 on Page 14.
Step 3
Install the four (4) spacer springs on the 4” flex vent
pipe. When installing the spacer springs around the 4”
pipe, stretch the spring to approximately 15” (381 mm),
wrap the spring around the pipe and interlock the ends
of the spacer spring approximately 2” (51 mm). Meas-
FP1242
ure 6³⁄₄” (172 mm) from the end of the pipe. Place the
next spring 5” (127 mm) from the previously installed
Fig. 22 Through the wall. spring. Place the next spring 6” (152 mm) from the last
STEP 7 spring. Finally place the last spring 12” (305 mm) from
the last spring installed. (Fig. 24)
Guide the vent terminations 4” and 7” collars into their
respective vent pipes. Double check that the vent pipes
overlap the collars by 2” (51 mm). Secure the termina-
tion to the wall with screws provided and caulk around
the wall plate to weatherproof. (Fig. 23) As an alterna- 4” Flex Vent
Pipe 12"
tive to screwing the termination directly to the wall you (305mm)
may also use expanding plugs or an approved exterior
construction adhesive. You may also attach the termi- Spacer Spring
nation with screws through the inner body into the 4”
6"
(102 mm) vent pipe however for this method you must (152mm)
extend the 4” (102 mm) pipe approximately 6” (152
mm) beyond the outer face of the wall. 5"
(127mm)

6���"
(172mm)
FP1474

Fig. 24 Install spacer springs.

10007852 15
FP1474
spacer springs
4/04 djt
Downloaded from www.Manualslib.com manuals search engine
LDVT Series Direct Vent Gas Fireplace

Step 4 1. Establish vent hole through the wall. (Fig. 18)


Install the 4” (102 mm) flex vent pipe to the appliance 2. Remove soil to a depth of approximately 16” (406
collar as described on Page 11. Secure the end with the mm) below base of snorkel. Install drain pipe. Install
first spring 6³⁄₄” (172 mm) from the flex pipe end to the window well (not supplied). Refill hole with 12” (305
unit. mm) of coarse gravel leaving a clearance of approxi-
Step 5 mately 4” (102 mm) below snorkel. (Fig. 26)
Slide the 7” (178 mm) flex vent pipe over the 4” flex 3. Install vent system.
vent pipe and secure the 7” collar as described on Page 4. Ensure a watertight seal is made around the vent
11. pipe coming through the wall.
Step 6 5. Apply high temperature sealant caulking (supplied)
around the 4” and 7 “ snorkel collars.
Bend the flex pipe horizontal so the bottom of the
horizontal pipe measure 6¹⁄₂” (165mm) from the top of 6. Slide the snorkel into the vent pipes and secure to
the unit immediately after the 90° formation. (Fig. 25) the wall.
Be sure to follow the 1” (25mm) rise in a 24” (610mm) 7. Level the soil to maintain a 4” (102 mm) clearance
horizontal run rule. below snorkel. (Fig. 26)
Step 7 Do not back fill around snorkel. A clearance
of at least 4” (102 mm) must be maintained
Install the 4” flex then 7” flex to the termination.
between snorkel and the soil.

Zero Clearance
Sleeve Screws
(if required) 7TDVSNORK
(Snorkel)
Firestop
4” (102mm)
7” Pipe Clearance
6���" (165mm) Min.

Window
24” (610mm) Well
Minimum*
FP1475
Gravel
Fig. 25 Bend flex vent at 90° so horizontal portion is 6¹⁄₂”
(165 mm) off top of unit. Drain

Below Grade Installations Foundation Wall


*A minimum of 24” (610mm) ver-
When it is not possible to meet the required vent ter- tical pipe must be installed when
using the 7TDVSNORK Kit.
minal clearances of 12” (305mm) above grade level a *The 22” (559mm) vertical rise
snorkel vent kit is recommended. It allows installation (center to center) of the snorkel
may be included for calculationof
depth of down to 7” (178mm) below grade level. The 7” max. horizontal run.
is measured from the center of the horizontal vent pipe BG402
as it penetrates through the wall. Fig. 26 Below grade installation.
If venting system is installed below
BG402a
If the foundation is recessed, use recess brackets (not
ground, we recommend a window well with
supplied) forTop Vent lower portion of the snorkel.
securing
adequate and proper drainage.
Belowtograde
Fasten brackets wall installation
first, then secure to snorkel
FP1475
Ensure sidewall venting clearances are observed.
1/26/00
with self drilling #8 xdjt
1/2 sheet metal screws. It will be
necessary to extend vent pipes out as far as protruding
If installing a snorkel a flex 90 24”
minimum bend(610 mm) vertical wall face. (Fig. 27)
rise is necessary. The maximum horizontal run with
the 24” (610 mm) vertical 4/04 djt36” (914 mm). This
pipe is
measurement is taken from the collar of the fireplace
(or transition elbow) to the face of the exterior wall.
Refer to the Sidewall Vent Graph for extended
horizontal run if the vertical rise exceeds 24” (610 mm).

16 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Example: Maximum horizontal length


0 x 45° elbows = 10’ (3 m)
1 x 45° elbows = 8¹⁄₂’ (2.6 m)
2 x 45° elbows = 7’ (2.1 m)

Snorkel • A minimum of an 8’ (2.4 m) vertical rise.


• Two sets of 45° elbows offsets within these vertical
Foundation Recess
installations. From 0 to a maximum of 8’ (2.4 m) of
Wall Screws vent pipe can be used between elbows. (Fig. 29)
Recess Brackets • 7DVCS must be used to support offsets. (Fig. 31)
Sheet Metal This application will require that you first determine
Watertight Seal Screws
Around Pipe the roof pitch and use the appropriate starter kit.
(Refer to Venting Components List)
BG401 • The minimum height of the vent above the highest
Fig. 27 Snorkel installation, recessed foundation. point of penetration through the roof is 2’ (610 mm).
(Fig. 33)
Vertical Through-the-Roof
BG401 Applications
Snorkel
This Gas Fireplace has been approved for:
2/10/99
• Vertical installations djt(12 m) in height. Up
up to 40’
to a 10’ (3 m) horizontal vent run can be installed
within the vent system using a maximum of two 90° Max. 8' (2.4m)
elbows. (Fig. 28)
4

1 + 2 + 3 + 4 = 270°

Max. 10' (3m)


Max. Height
40' (12m) 3

Min. Height
7���' (2.3m)

1 2

Pipe Straps Every


3’ (914mm)

FP1244
FP1245
Fig. 28 Support straps for horizontal runs.
Fig. 29 Typical offset application.
• Up to two 45° elbows may be used within the
horizontal run. For each 45° elbow used on the
FP1245
horizontal level the maximum horizontal length must
through the roof
be reduced by 18” (457 mm). 90 & 45 degree
FP1244 12/02
through the roof
max/min dims
12/02
10007852 17

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Vertical Through-the-Roof Installation


1. Locate your fireplace.
2. Plumb to center of the (4” (102 mm) flue collar from
ceiling above and mark position.
3. Cut opening equal to 9³⁄₈” x 9³⁄₈” (240 x 240 mm).
4. Proceed to plumb for additional openings through
the roof. In all cases, the opening must provide a
minimum of 1” (25mm) clearance to the vent pipe, i.e.,
the hole must be at least 9³⁄₈” x 9³⁄₈” (240 x 240 mm). Typical Roof Support Typical Ceiling Sup-
Application port Application
5. Place fireplace into position.
6. Place firestop(s) #7DVFS or Attic Insulation Shield CFM110

#7DVAIS into position and secure. (Fig. 30) Fig. 31 Roof and ceiling supports.

Attic Insulation
Shield
CFM110
Typical ceiling/roof support
#8 Sheet Metal Screws
Joist 10/90 (3 per joint)
Sealant
Storm Collar

Ceiling In- 11"


11"
(279mm)
Upper Floor TWL101a
(279mm)
stallation
Fig. 32 Roof flashing.
Joist TWL101a
Twist Lock Pipe
2/8/99 djt

Firestop Spacer

Nails (4) Min.


CFM100a
2' (610 mm)
Fig. 30 Place firestop spacer(s) and secure.
CFM100a
Firestop-Vertical
7. Install roof support (Fig. 31) and roof flashing making
sure upper flange of flashing is below the shingles.
(Fig. 32)
8. Install appropriate pipe sections until the venting is
above the flashing. (Fig. 32)
9. Install storm collar and seal around the pipe.
10. Add additional vent lengths for proper height. (Fig.
33)
CFM190

Fig. 33 Minimum termination to roof clearance.

If there is a room above ceiling level,


firestop spacer must be installed on both
the bottom and the top side of the ceiling
joists. If an atticCFM190
is above ceiling level a
TTR Ternim.
7DVAIS (Attic Insulation 2'
Shield) must be
installed. 1/25/02 sta

The enlarged ends of the vent section


always face downward. (Fig. 32)

18 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Vertical Restrictor Plate


36LDVT, 39LDVT, 43LDVT Rear Log Support

When installing the 36LDVT, 39LDVT or 43LDVT with a


vertical through-the-roof configuration flue system, the
restrictor plate (#10008048) supplied with the appliance
MUST BE FITTED TO THE APPLIANCE at the instal-
lation.
NOTE: Do not use the restrictor plate supplied with
the vertical termination cap.
1. Remove the rear log support. Save the two (2)
screws. Restrictor Plate
FP1555
2. Remove the two (2) nuts and save them.
Fig. 34 Assembling the restrictor plate.
3. Place the restrictor plate (Fig. 34) and secure it with
the two (2) nuts.
4. Replace the rear log support to the same location
as before and secure it with the screws removed in
Step 1.
������
����������������
����

10007852 19

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Venting Components

7TDVRVT - Through the wall Rear Vent Termination

584A Starter Kit -


venting components
rear vent term Model 7TDVSK - Sidewall Venting (Twist Lock Pipe)
4/6/99 djt
Model 7FDVSK - Sidewall Venting (Flex Vent Pipe)
Models 7TDVTK/TV - Hot Touch Termination Kits
Model 7TDVTVTK/TV - Cool Touch Termination Kit
Starter Kit - Model 7TDVSKV - Vertical Venting
for 7TDVSKV-A order 1/12 to 6/12 roof pitch
for 7TDVSKV-B order 7/12 to 12/12 roof pitch
for 7TDVSKV-F order flat roof
Starter Kit for Below Grade Installation
Model 7TDVSKS -Snorkel Kit (Twist Lock Pipe)
Model 7FDVSKS -Snorkel Kit (Flex Vent Pipe)
Starter Pipe
584B Model 7TDVP 20/8 - 24” Starter Pipe Bulk
Vent components Model 7FDVP 30/8 - 30” Flex Pipe Bulk
Starter Kit
2/25/99 djt
45o Elbow
7TDV45 for Rear Vent to Vertical Vent
or Vertical/Horizontal Offsets

90o Transition Elbow


7TDVRT90 for Rear Vent to Vertical Vent
90° Elbow
7TDV90 Vertical/Horizontal Offset
584C Telescopic vent sections
7TDVP1117 -11” to 17” adjustable length
Vent components
584D 7TDVP3567 -35” to 67” adjustable length
45 degree
Vent elbow
Components Pipe sections for vertical or horizontal venting
902/25/99
degree djt
elbow Model 7TDVP8” - 4 per box
10/20/99djttwistlock
584E
2/25/99
Model 7TDVP12”
Model 7TDVP24”
-
-
4 per box
4 per box
Venting Components Model 7TDVP36”
10/20/99
Telescope venttwist lock Model 7TDVP48”
584F
2/25/99 djt
Venting Components Firestop Spacer
10/20/99 twist lock
Pipe sections Model 7DVFS
2/25/99 djt
10/20/99 twist lock
Attic Insulation Shield
Model 7DVAIS
584G
Venting Components
Firestop spacer
2/25/99 djt
Vertical/Horizontal Combination Offset Support
584H
Venting components
Model 7DVCS
attic insulation shield
2/25/99 djt
20 584I 10007852
vent components
offset support
2/25/99 djt

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Operating Instructions
Glass Information 6. Tilt the glass frame out slightly at the bottom, lift the
frame up and away from the fireplace.
Only glass approved by CFM Corporation
7. To replace the glass frame reverse the procedure.
should be used on this fireplace.

• The use of any non-approved replacement glass will


void all product warranties.
• Care must be taken to avoid breakage of the glass.
• Do not operate appliance with glass front
removed, cracked or broken.
• Replacement glass (complete with frame
window) is available through your CFM
Corporation dealer and should only be installed
by a licensed qualified service person. Lower Clamps

� ������� Window
�������������� Frame As-
sembly
������������
Window
������������������ Frame
Pull
Assembly
������������� Push Clamp
Clamp Hook
�������������������� Handle
��������������� FP1228

Fig. 36 Window frame assembly removal.


Louvre Removal
The top louvre Glass Cleaning
panel is removed
by lifting the It is necessary to periodically clean the glass. During
2. FP1228
panel vertically start-up condensation, which is normal, forms on the
and pulling it remove
inside of the glass. This glass frame
condensation causes lint, dust
Louvre
away from the 1.
11/02
and other airborne particles to cling to the glass surface.
appliance. (Fig. Also initial paint curing may deposit a slight film on the
35) glass. It is therefore recommended that the glass be
The lower access cleaned two or three times with a non-ammonia based
door is hinged household cleaner and warm water (We recommend
along the bottom gas fireplace glass cleaner) within the first few weeks of
edge and is Glass Panel operation.
folded down to FP1227
After the initial cleaning process the glass should be
allow access Fig. 35 Remove top louvre assembly. cleaned two or three times during each operating
season depending on the environment in the house.
Window Frame Assembly FP1227Removal
Louvre removal Clean the glass after the first two weeks of
1. Turn the fireplace OFF (including the pilot) operation.
11/02
2. If the unit has been operating allow time for the Do not clean glass when hot.
components to cool.
Do not use abrasive cleaners.
3. Remove the top louvre assembly.
4. Open the lower louvre panel. Do not strike or slam glass.
5. Release the two clamps securing the lower edge of
the frame by pulling down on the handles. (Fig. 36)

10007852 21

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

Installation of Logs, Lava Rock & Ember Material


The logs are fragile and should be handled
with care. Keep the packaging material out 33LDVT
of the reach of children and dispose of the 1. Place rear log left (A41) on rear bracket (ensure the
material in a safe manner. notch on the left end locates against the bend up on
The individual logs can be easily identified the left side of rear bracket.)
by the numbers cast on the underside of 2. Place rear log right (A42) on rear bracket (ensure
each log. the notch on the right end locates against the bend
up on the right side of rear bracket) and just rest the
Log Identification Chart cut out from front log onto the front support.
Location 33LDVT 36LDVT 39LDVT 43LDVT 3. Place front log left (A43). Use the log’s bottom hole
Front Left A43 B160 BC15 BD16 to locate it onto rear log left (A41) and just rest bot-
Front Right -- B159 BC16 BD17 tom cut out log onto the front support.
Front Center -- B161 B138 B138 4. Place top log center (A44). Use the log’s bottom
Rear -- B158 BC14 BD15 hole to locate it onto the knob on the rear log right
Rear Left A41 -- -- -- (A42) and the top log center rest onto rear log left.
Rear Right A42 -- -- -- 5. Place ember material on top of burner. Scatter the
Top Center A44 -- -- BD18 ember material over the tiles on the front area of the
burner housing. (Fig. 44) Do not pack the ember
Log Installation material. Separate it when unpacked and keep it
in a fluffy and loose condition for a more realistic
1. Remove the top louvre assembly. ember effect.
2. Open the bottom louvre. 6. Scatter the lava rock material around the firebox
3. Remove the window frame assembly. base.
4. Remove log box from inside firebox. Do not place any of the lava rock material
5. Unpack the logs from packaging and remove each on the burner housing assembly.
log from its wrapping material. Set aside the ember
and the lava rock bags.
As with all plastic bags - these are not toys
and should be kept away from children and
infants.

Top Center
Rear Left (A44)
(A41) Rear Right
(A42)

Front Left
LG382
(A43)
Fig. 37 Correct log placement for 33LDVT.

22 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

36LDVT
1. Place rear log (B158) on rear brack- Rear
et (ensure log is seated properly to (B158)
the bracket and located to the two
pins), so it will not move from side to
side and is firmly positioned on the
bracket.
2. Place front left log (B160). Use the
log’s bottom hole to locate it onto
the front support and just rest on top
of the rear log.
3. Place front right log (B159). Use the
log’s bottom hole to locate it onto
the front support and the top hole to
the knob onto the rear log.
4. Place front center log (B161) on top
of the two small shelves at the front
log support and between the left
and right logs.
Front Left Front Right
5. Place ember material on top of (B160) Front Center (B159)
burner. Scatter the ember material (B161) LG481
over the tiles on the front area of Fig. 38 Correct log placement for 36LDVT.
the burner housing. (Fig. 45) Do not
pack the ember material. Separate it when unpacked Do not place any of the lava rock material
and keep it in a fluffy and loose condition for a more on the burner housing assembly.
realistic ember effect.
6. Scatter the lava rock material around the firebox
base. �����
39LDVT ����������
1. Place rear lob (BC14) on rear bracket
����
(ensure log is centered and seated Front Left
(BC15) Front Right
properly to the log support). (BC16)
2. Place front left log (BC15). Use log’s Rear
bottom hole to locate it onto the front (BC14)
support and just rest on top of the
rear log.
3. Place front right log (BC16). Use log’s
bottom hole to locate it onto the front
support and the top hole to the knob
on the rear log.
4. Place front center log (B138) on top
of the two small shelves at the front
log support, and between the left and
right logs.
5. Place ember material on top of
burner. Scatter the ember material
Front Center
over the tiles on the front area of the (B138) LG414
burner housing. (Fig. 46) Separate it
when unpacked and keep it in a fluffy Fig. 39 Correct log placement for 39LDVT.
and loose condition for a more realis-
tic ember effect. Do not place any of the lava rock material
on the burner housing assembly.

10007852 ����� 23
����������
Downloaded from www.Manualslib.com manuals search engine ����
LDVT Series Direct Vent Gas Fireplace

43LDVT
1. Place rear log (BD15) on rear bracket
(ensure log is centered and seated Top Center
(BBD18)
properly to the log support). Rear
(BD15)
2. Place front left log (BD16). Use log’s
Front Right
bottom notch to locate it onto the front (BD17)
support and just rest on top of the
Front
burner housing assembly. Left
3. Place front right log (BD17). Use log’s (BD16)
bottom notch to locate it onto the front
support and just rest on top of the
burner housing assembly.
4. Place ember material on top of burner.
5. Scatter the ember material over the
tiles on the front area of the burner
housing. (Fig. 40) Do not pack the
ember material. Separate it when
unpacked and keep it in a fluffy and Lava
Rock
loose condition for a more realistic
Lava Rock
ember effect. Ember Material
6. Place front center log (B138) on top of
Front Center
the two small shelves at the front log (B138) LG434
support, and between the left and right
logs. Fig. 40 Correct log placement for 43LDVT.
7. Place top center log (BD18) on top of �����
Do not place any of the lava rock material
the rear log using the hole locator under the log and
on top of front right log. ����������
on the burner housing assembly.
8. Scatter lava rock material round the firebox base. �����
Flame Characteristics
Flame & Temperature Adjustment It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to Figures
RN/RP & EN/EP Models 43 and 44.
For units equipped with ‘HI/LO’ valves the flame If the flame patterns appear abnormal contact a
adjustment is accomplished by rotating the ‘HI/LO’ qualified service provider for service and adjustment.
adjustments knob located near the center of the gas
control valve. (Fig. 41-42)

Turn SIT RN/RP


counterclockwise �� Turn clockwise
��

to decrease to increase
flame height flame height

Fig. 41 Flame adjustment knob for Honeywell valve.

SIT EN/EP
Turn
counterclockwise HV102 Turn clockwise
HI

Honeywell hi/lo knobto decrease


to increase 4/5/99 djt flame height
LO

flame height
Fig. 42 Flame adjustment knob for SIT valve. FP1541

Fig. 43 Correct pilot flame appearance.

24 FP390 10007852
FLAME ADJUSTMENT KNOB
11/21/96

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

33LDVT

LG384

Glowing Embers

36LDVT

LG482

LG384
Glowing Embers
33LDV log flames
1/05
39LDVT

�����
LG415
����������������
����
Glowing Embers

�����
����������������
43LDVT
����

LG435

Glowing Embers

Fig. 44 Correct burner flame appearance for the LDVT fireplaces.

10007852 25

Downloaded from www.Manualslib.com manuals search engine


�����
LDVT Series Direct Vent Gas Fireplace

Lighting and Operating Instructions


FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu- Follow the gas supplier’s instructions.
ally. When lighting the pilot follow these instruc- • If you cannot reach your gas supplier, call
tions exactly. the Fire Department
B. BEFORE LIGHTING smell all around the C. Use only your hand to push in or turn the gas
heater area for gas. Be sure to smell next to control knob. Never use tools. If the knob will not
the floor because some gas is heavier than air push in or turn by hand, do not try to repair it, call a
and will settle on the floor. qualified service technician. Applying force or any
WHAT TO DO IF YOU SMELL GAS attempted repair may result in a fire or explosion.
• Do not try to light any fireplace D. Do not use this fireplace if any part has been under
• Do not touch any electric switch water. Immediately call a qualified service techni-
• Do not use any phone in your building cian to inspect the heater and to replace any part of
the control system and any gas control which has
• Immediately call your gas supplier from a been under water.
neighbor’s phone.

Lighting Instructions
1. STOP! Read the safety information above. 10. Push the control knob all the way in and hold.
2. Turn off all electrical power to the fireplace. Immediately light the pilot by repeatedly depress-
3. For MN/MP/TN/TP appliances ONLY, go on to ing the piezo spark ignitor until a flame appears.
Step 4. For RN/RP appliances turn the ON/OFF Continue to hold the control knob in for about one
switch to “OFF” position or set thermostat to (1) minute after the pilot is lit. Release knob and it
lowest level. will pop back up. Pilot should remain lit. If it goes
4. Open control access panel. out, repeat steps 5 through 8.
5. Push in gas control knob slightly and turn clock-
wise to “OFF”. 3/8" - 1/2"

���
PILOT

��
��
1 2
Pilot

��
OFF

��
OFF

O FF
3 4 5

Euro SIT SIT NOVA Honeywell


• If knob does not pop up when released, stop
6. Wait five (5) minutes to clear out any gas. Then and immediately call your service technician or
smell for gas, including near the floor. If you gas supplier. FP1068
smell gas, STOP! Follow “B” in the safety infor- • If after several tries,Lighting
the pilotinstructions
will not stay lit,
mation above. If you
FP1067
do instruction
not smell gas, go to the turn the gas control knobPilots
to “OFF” and call your
lighting
next step. knobs
service technician or gas supplier.
7. Remove glass door 3/9/01
beforedjt lighting pilot. (See 11. Replace glass door.
Glass Frame Removal section). 12. Turn gas control knob to “ON” position.
8. Visibly locate pilot by the main burner. 13. For RN/RP appliances turn the ON/OFF switch to
9. Turn knob on gas control counterclockwise “ON” position or set thermostat to desired setting.
to “PILOT”. 14. Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater


1. Turn the ON/OFF switch to Off position or set 3. Open control access panel.
the thermostat to lowest setting. 4. Push in gas control knob slightly and turn clock-
2. Turn off all electric power to the fireplace if wise to “OFF”. Do not force.
service is to be performed. 5. Close control access panel.

26 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Lighting and Operating Instructions


For Fireplaces equipped with SIT822 Gas Valve (EN or EP)
Warning:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury and loss of life.

FOR YOUR SAFETY READ THE FOLLOWING WARNINGS


BEFORE LIGHTING THE APPLIANCE

A. This fireplace is equipped with an ignition device Follow the gas suppliers instructions.
which automatically lights the pilot. DO NOT try to • If you cannot contact your gas supplier call
light the pilot by hand. the Fire Department
B. BEFORE OPERATING, smell all around the C. Use only your hand to push in or turn the gas
appliance area for gas. Be sure to smell next to control knob. Never use tools. If the knob will not
the floor because some gas is heavier than the air push in or turn by hand do not try to repair it, call
and will settle on the floor. a qualified service technician. Force or attempting
What to do if you smell gas repair may result in a fire or explosion.
• Do not try to light any appliance D. Do not use this appliance if any part has been
• Do not operate any electrical switch. under water. Immediately call a qualified service
technician to inspect the appliance and replace
• Do not use any phone in your building. any part of the control system and any gas control
• Immediately call your gas supplier from a that has been under water.
neighbor’s phone.

Lighting Instructions
1. STOP! Read the safety information above before 5. Turn the remote switch, if used, OFF. Turn the
continuing. wireless remote, if used, OFF.
2. Turn off all electrical power to the appliance. 6. Wait five (5) minutes to clear out any gas. Then
3. This appliance is equipped with an ignition device smell for gas, including near the floor. If you smell
which automatically lights the pilot. DO NOT try to gas STOP. Follow instructions B in the safety
light the pilot by hand. warnings above. If you do not smell gas go onto the
4. Access the gas control by lowering the lower next step.
access door (louvre assembly). 7. Close the access door.
8. Turn ON all electrical power to the appliance.
9. Turn remote switch or wireless remote to “ON”.
10. If the appliance will not operate, follow the
LO instructions TURNING OFF THE GAS TO THE
APPLIANCE and call your service technician or
HI gas supplier.

Turning Off the Gas to the Appliance


1/2” Gas Supply
1. Turn the remote switch to the “OFF” position.
1/2” NPT x 1/2” Flare Shut-Off
2. Turn OFF all electrical power to the fireplace if Valve
service is required. 3/8” Flex Line
(From Valve)
3 Open the lower access panel.
4. Turn the shut-off valve on the flexible gas line to
the “OFF” position.
Valve in the on position FP297A

10007852 27
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY
Downloaded from www.Manualslib.com manuals search engine 7/1/98
LDVT Series Direct Vent Gas Fireplace

Troubleshooting Honeywell Millivolt Valve

Remove Window Frame Assembly Before Service Work

START CHECK

Gas Supply On NO • Supply Line Hooked Up


• Shutoff Valve Open

YES

• Lockout Has Engaged. Wait 60


Seconds And Try Again.
• For Spark At Electrode While
Pilot Lights With Piezo Depressing Piezo
NO
Ignitor 1/8" Gap To Pilot Hood Needed.
• All Wiring Connections
• Replace Piezo Ignitor

YES • For Air In The Lines


• Thermopile Needs A Min.
325mv. Adjust Pilot Flame
Height.
• All Wiring Connections
Pilot Stays Lit NO
• Replace Thermopile
• Thermocouple Needs A Min. Of
14mv
• Defective Valve. Turn To Pilot,
Meter Should Read Greater
YES Than 100mv. If Not, Replace.

• Valve Is Turned On
• Wall Switch Is Not Turned On.
Pilot Lights Main Burner NO Watch For Grounded Wires!
• Thermopile Needs A Min. 325mv.
• Plugged Burner Orifice
YES

SYSTEM OK

28 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Troubleshooting the Gas Control System


SIT 822 Valve with Synetek Electronic Control
Operating Diagram

Normal Operation Abnormal Operation

ON/OFF Switch Closed? 5 sec Inter-Trial Delay


YES

Safe Start Check On? NO LED: Steady Flash?


Lockout: Flame detected out of sequence
YES Reset by interrupting ON/OFF switch or
power for 10 sec

0 Sec Purge
LED: 5 Flashes?
Reverse power cord polarity

Ignition Trial: 30 sec Spark ON


Pilot Valve ON. Has Flame NO LED: 2 Flashes?
been Detected within 30 sec? Reset by interrupting ON/OFF
switch for power for 10 sec

YES
Pilot, Valve OFF, Spark OFF
Spark Off. Main Valve ON. NO
Have three ignition trials been completed?
Pilot Flame Continuously
Monitored

LED: 3 Flashes?
Lockout: Flame Loss
Reset by interrupting ON/OFF switch or
Pilot Flame Sense OK? NO
power for 10 sec

YES Main Valve OFF, Spark ON


ON/OFF Switch Opened? Has flame been detected within 30 sec?

YES
NO
Have three pilot flame losses been
Pilot and Main Valve OFF? YES
detected?
YES

0 sec Post Purge?

Heating Cycle Complete LED:


OFF

10007852 29

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace
CONVERTING THE APPLIANCE FROM LP TO 9. PSE Pilot
NATURAL GAS OR NATURAL GAS TO LP Using a suitable wrench on the hexagonal body, un-
screw the pilot hood assembly from the pilot, do not
The conversion of this appliance from one twist the hood itself. Remove the orifice and replace
gas to another must be carried out by an it with the new orifice supplied in the kit. Refit the
authorized service provider. pilot hood assembly. Do not over-tighten the pilot
hood. The hood must return to its original alignment.
The procedure for converting from one gas
Take care not to damage the thermocouple, thermo-
to another is the same regardless of the
pile or igniter.
initial gas used. The only variation is in the
10.SIT 820 NOVA Gas Control Valve (Fig. 46)
orifice-sizes and component part numbers.
a. Using a Torx T20 or slotted screwdriver, remove
Your authorized service provider will
and save the three pressure regulator mount-
ensure the correct parts are used.
ing screws (A), pressure regulator tower (B) and
1. Disconnect power to unit and shut off gas supply. diaphram (C).
2. Remove window frame assembly.
3. Carefully remove the logs & lava rock material. A E
4. Remove the screws that are holding the burner
housing assembly in place. B

5. Remove the burner housing assembly. Depending


on the model of the appliance you may have to loos- C
en the pilot bracket retaining screw/nut to allow the
pilot and bracket assembly to tilt and give enough OF

FP
IL
O OT

clearance to remove the burner housing assembly.


D
OF

6. For Model 36LDVT ONLY: Remove the rear log

FP
IL
O OT

support and relocate the two (2) screws that locate


the rear log as shown in Figure 45.
F
Natural Gas

820

FC107
Fig. 46 Nova SITSIT820
820 gas valve. FC108
valve conversion

b. Ensure the10/03
rubber gasket
SIT(D) is properly posi-
Log Locator tioned and install the new regulator
Hi/Lo pressure regula-
Pin
tor to the valve using the newconversion
screws (E) supplied
10/03
with the kit. Tighten screws securely. (Reference
Propane Gas torque - 25 in.LB)

c. Install the enclosed identification label (F) to the
valve body where it can be easily seen.
Honeywell Gas Control Valve (Fig. 47)
The Honeywell valve fitted to this unit is suitable for
use with LP or Natural Gas. It is converted to the
required gas application by the installation of a color
Log Locator
Pin coded “conversion screw”.
KT615
a) Using a suitable small screwdriver lift out the
central regulator cap from the “Hi - Lo” knob on
Fig. 45 Move log locator pins to new locations on rear log the valve.
support. b) Unscrew the exposed conversion screw.
7. Remove the main burner orifice and replace it with c) Insert the new color coded conversion screw.
the orifice supplied in the conversion kit. Do not over-tighten the screw, it must be finger
8. SIT top Convertible Pilot����� tight.
Gently lift off the pilot hood from the pilot. (Do not
���������������� d) Refit the regulator cap.
remove the spring clip holding the hood in place). e) Mount the conversion label supplied with con-
���� the exposed orifice.
Using a 5/32” Allen key, unscrew version screw to the valve in a visible position.
Insert the new orifice supplied in the kit, do not over 11. Reassemble the fireplace in the reverse order, ex-
tighten the orifice. Replace the pilot hood ensuring cept for the window frame assembly. Leave this off
the index tab aligns with the notch on the hood. until after the unit has been checked for leaks and
the gas supply has been bled.
30 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

12. After bleeding the gas line and checking for leaks
with a soap solution, replace the window frame Regulator Cap Conversion Screw
assembly. Fire up the unit, check for flame impinge-
ment on the logs, adjusting them if necessary. Check
manifold and supply pressures against appliance
specifications. LO

Pressure Regu-
lator Housing

HV120

Fig. 47 Honeywell gas valve.

Maintenance
Burner and Burner Compartment Most of theseHV120
components may require only an
It is important to keep the burner and the burner occasional checkup and cleaning
Honeywell valve and some may
compartment clean. At least once per year the logs and require adjustment. If repair is necessary, it should
conversion
lava rock/ember material should be removed and the be performed by a qualified technician.
9/24/02 djt
burner compartment vacuumed and wiped out. Remove 1. Turn off pilot light at gas valve.
and refit the logs as per the instructions in this manual. 2. Allow fireplace to cool if it has been operating.
Always handle the logs with care as they 3. Remove window frame assembly. (Refer to Window
are fragile and may also be hot if the Frame Assembly Removal section.)
fireplace has been in use. 4. Remove logs.
FK24/FK12 Fan Assembly 5. Vacuum burner compartment especially around
orifice primary air openings.
The fan unit requires periodic cleaning. At least once
6. Visually inspect pilot. Brush or blow away any dust
per month in the operating season open the lower
or lint accumulation.
louvre panels and wipe or vacuum the area around the
fan to remove any build up of dust or lint. 7. Reinstall logs.
8. Ignite pilot - Refer to Lighting Instructions.
Brass Trim
9. Reinstall window frame assembly.
Clean the brass trim pieces using a soft cloth lightly
To obtain proper operation, it is imperative that the pilot
dampened with lemon oil. Do not use water or
and burner’s flame characteristics are steady, not lifting
household cleaners on any brass components.
or floating.
Cleaning the Standing Typically, the top 3/8” to 1/2” of the thermopile should
Pilot Control System be engulfed in the pilot flame. (Refer to Page 24, Figure
43)
The burner and control system consist of:
To adjust pilot burner: (by qualified service technician)
• burner • gas orifice 1. Remove pilot adjustment cap
• pilot assembly • thermopile
2. Adjust pilot screw to provide properly sized flame.
• millivolt gas valve
3. Replace pilot adjustment cap.
The primary air shutter is set at factory and should
only be adjusted, if necessary, by a qualified service
technician.

10007852 31

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

1 1 36LDVT 1 39LDVT 43LDVT


33LDVT 1d
1d
1d
1e
1b
1a 1b
1f
1g 1b
1c 1a
1a
1a 1g 1c 1c

1h 1i 2 3 12 14 11 9
7a,b 16
6a,b

18a,b
19a,b
15 13
17
LO
8
HI
21 20

23
26
31
29

22

24

33 25
32
30

40
39

35

34

42 41

43
44
37

CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time,
with out notice.

33/36/39/43LDVT 7852
LDVT parts
1/05
33LDVT units: GFTN2I0, GFTL2I0, GFTE2I0 �����
36LDVT units: GFTN2J1, GFTL2J1, GFTE2J1
39LDVT units: GFTN2K0, GFTE2K0
43LDVT units: GFTN2N0, GFTE2N0

32 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

33/36/39/43LDVT (continued)
Ref. Description 33LDVT 36LDVT 39LDVT 43LDVT
1. Log Set (complete) 10007567 10010113 10008214 10008314
1a. Front Left Log A43 B160 BC15 BD16
1b. Front Right Log -- B159 BC16 BD17
1c. Front Center Log -- B161 B138 B138
1d. Rear Log -- B158 BC14 BD15
1e. Rear Left Log A41 -- -- --
1f. Rear Right Log A42 -- -- --
1g. Top Center Log A44 -- -- BD18
1i. Lava Rock Package 10001454 10001454 10001454 10001454
1k. Ember (Package) 51915 51915 51915 51915
2a. Burner Housing Assy - Natural 10007558 10007127 10008218 10008464
2b. Burner Housing Assy - Propane 10007558 10008042 10008586 10008587
3. Ceramic Tile (Single) 57803 57803 57803 57803
4a. Orifice Burner - Natural Refer to Rating Plate for Orifice Size
4b. Orifice Burner - Propane Refer to Rating Plate for Orifice Size
5a. Orifice Pilot - Natural 10002268 10002268 10002268 10002268
5b. Orifice Pilot - Propane 10002269 10002269 10002269 10002269
6a. Pilot Assy SIT - RN 10002264 10002264 10002264 10002264
6b. Pilot Assy SIT - RP 10002265 10002265 10002265 10002265
7a. Pilot Assy SIT - EN 10002387 10002387 10002387 10002387
7b. Pilot Assy SIT - EP 10002388 10002388 10002388 10002388
8. Pilot Tubing w/Fittings SIT 10001296 10001296 10001296 10001296
9. Pilot Hood 10002385 10002385 10002385 10002385
10. Manifold Tubing w/Fittings 57318 57318 57318 57318
11. Thermocouple - RN/RP 53373 53373 53373 53373
12. Thermopile - RN/RP 51827 51827 51827 51827
13. Electrode Ignitor w/Cable -RN/RP 10001297 10001297 10001297 10001297
14. Electrode Ignitor - EN/EP 52465 52465 52465 52465
15. Cable Ignitor - EN/EP 10000696 10000696 10000696 10000696
16. Sensing Electrode - EN/EP 57885 57885 57885 57885
17. Ignitor Piezo, SIT 820 Valve 52464 52464 52464 52464
18a. Valve SIT 820 - RN 52677 52677 52677 52677
18b. Valve SIT 820 - RP 52678 52678 52678 52678
19a. Valve SIT 822 - EN 57884 57884 57884 57884
19b. Valve SIT 822 - EP 57883 57883 57883 57883
20. Flexible Gas Line w/ON/OFF Shut-off Valve 20002500 20002500 20002500 20002500
21. Fan Assy (w/Brkt) (FK24 Option) ZA1100 ZA1100 ZA1100 ZA1100
22. Fan Assy (FK12 Option) ZA1110 ZA1110 ZA1110 ZA1110
23. Electrical Cord (6 ft.) 51865 51865 51865 51865
24. Fan Temperature Sensor (FK24) 51704 51704 51704 51704
25. Speed Control (FK24) 51738 51738 51738 51738
26. Speed Control Knob (FK24) 51882 51882 51882 51882
29. Frame Window w/glass 10009693 10009694 10009695 10008535
30. Clamp Frame Window 54174 54174 54174 54174
31. Top Louvre Assy 10007400 10007090 10007984 10008311
32. Bottom Louvre Assy 10007397 10007092 10007986 10008307

10007852 33

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

33/36/39/43LDVT (continued)
Ref. Description 33LDVT 36LDVT 39LDVT 43LDVT
33a. Support Rear Log - Natural 10007561 10007162 10008211 10008480
33b. Support Rear Log - LP 10007561 10008045 10008211 10008490
34. Support Front Log 10007562 10007112 10008416 10008469
35. ON/OFF Switch 51842 51842 51842 51842
37. Relief Plate Assy (Burner Base) 10004192 10004192 10004192 10004192
38. Remote Switch Kit (Not Shown) 53875 53875 53875 53875
39. Ignition Control from Synetek (EN) 10007939 10007939 10007939 10007939
40. Wire Harness (EN) Synetek (low voltage) 10008139 10008139 10008139 10008139
41. Wire Harness (EN) Synetek (high voltage) 10008140 10008140 10008140 10008140
42. Restrictor Plate -- 10008048 10008048 10008048
43. Clevis Pin 10008615 10008615 10008615 10008615
44. Clip Pin Hitch 10008616 10008616 10008616 10008616

Fuel Conversion Kits


Conversion Kit, NG to LP
33LDVT Kit # 10008233
36LDVT Kit # 10008235
39LDVT Kit # 10008237
43LDVT Kit # 10008239
Conversion Kit, LP to NG
33LDVT Kit # 10008234
36LDVT Kit # 10008236
39LDVT Kit # 10008238
43LDVT Kit # 10008240

34 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Optional Accessories
Fan Kits Thermal Sen-
sor Fan
FK24 Fan Assembly
This auxiliary fan system increases the efficiency of the
circulation of the heating air.
The FK24 fan kit allows variable speed control of the
circulation fan and also incorporates a heat sensor in
the circuit.
Specifications
115 Volt / 60Hz / 56 Watts Fan Speed Gas EB-1
Lines Receptacle
Maintenance FP1230 Switch Box
The fan itself does not require regular maintenance,
Fig. 48 FK24 fan placement.
however periodic cleaning of the fan and the
surrounding area is required. FK12
Check the area under the control door (lower louvre This auxiliary fan system increases the efficiency of the
assembly) and in front of the fan and wipe or vacuum this FP1230
circulation of the heating air.
area at least once a month during the operating season. The FK12 Fan Assembly is FK24
a fixed speed fan system
Installation fan install
and does not allow for variable speed control. It does
The fan assembly and other components are supplied not use the speed control 11/02
unit or the heat sensor used
fully wired eliminating the need for a licensed electrician in the FK24 Kit.
to carry out the installation. Specifications
If hard wiring the fan using Method B (following), we 115 Volts / 60 Hz / 56 Watts.
strongly recommend the use of a licensed electrician. Maintenance
1. Open the lower louvre assembly. Maneuver the fan The fan itself does not require regular maintenance,
& bracket assembly around the gas valve and lines however periodic cleaning of the fan and the
to locate the unit onto the screw studs on the back of surrounding area is required.
the fireplace.
2. Install the thermal sensor under the bottom of the of Check the area under the control door (lower louvre
the firebox, locating it over the two 10 mm studs and assembly) and in front of the fan and wipe or vacuum this
secure it with nuts. area at least once a month during the operating season.
3. Locate the fan speed control unit. This can be fitted Installation
behind the lower louvre assembly as in Figure 48 The fan assembly is supplied fully wired eliminating the
or located remotely in a conveniently located wall need for a licensed electrician to carry out the installation.
mounted electrical box. Remote location of the 1. Open the lower Louvre assembly. Maneuver the
speed control will require suitable extension of the fan & bracket assembly around the gas valve and
component wiring. lines to locate the unit against the back wall of the
4. The power supply may be connected in two ways: appliance, resting on the base.
Method A 2. With the protective cover removed from the self-
Route the 6’ lead fitted to the unit to a conveniently adhesive ‘Velcro’ strips apply mild pressure to the
located wall socket. fan & bracket unit to secure the strips to the metal
Method B (Using EB-1 Receptacle Box) panels. No further securing is required.
The EB-1 receptacle box (Pt. # ZA1200) may be 3. Power to the fan can be supplied by plugging the
hard wired into the house supply. The fan lead is supplied lead into a conveniently located wall socket
then plugged into the EB-1 box. For instruction on or by using a hard-wired EB-1 connector box.
wiring the EB-1 Electrical Junction Box see the
earlier chapter in the Installation section of this
manual.

10007852 35

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

For aesthetic purposes we recommend


Wiring Instructions
lining up the horizontal mortar lines.
The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electric Code.
Side
For USA installations follow the local Panel
Back Panel Side
codes and the national electrical code Panel
Log Support
ANSI/NFPA No. 70. Burner Tray

Should this fan require servicing or repair


the power supply must be disconnected. FP1231
For rewiring of any replacement parts refer
to Figure 49. Fig. 50 Ceramic panel installation.

Any electrical re-wiring of this fan must be


Rear Refractory
done by a licensed electrician. Panel

Firebox Back
Fan
FP1231 Panel
Temperature Sensor Rear Panel Sup-
port Brackets Ceramic panels
Speed Control 11/02
Black
White
Ground Rear Log
Support
FP1025
FP1232
Fig. 49 FK24 fan wiring. FP394 Fig. 51 Rear refractory panel installation.
WIRING DIAGRAM
Ceramic Refractory
11/20/96
Panels
Remote Controls
Ceramic refractory panels are available for the LDV
series appliances Optional remote control FP1232
units are available to control
Kit Model and Finish different functions of the appliances
rear ceramic panel
Unit Sandstone Red Black Grey Model Function/s Controlled
33LDVT GAHC3I0 GAFC3I0 GABC3I0 GAGC3I0
11/02
RCI ON/OFF
36LDVT GAHC3J0 GAFC3J0 GABC3J0 GAGC3J0 RC2 ON/OFF and Temperature.
39LDVT 39LDVCR
IMTFK Wall mounted thermostat control
43LDVT 43LDVCR
Take care when handling the refractory
panels as they are fragile until held in place
and supported.
Installation, refer to Figures 50 & 51
1. Remove the front window frame assembly.
2. Remove the logs.
3. Place the rear refractory panel in place. Locate the
lower edge of the panel in the ledge formed by the
top of the rear log support bracket.
4. Slide the side refractory panels into place to hold
the rear panel secure. Repeat the procedure on the
other side.
5. Replace the logs and window frame assembly.

36 10007852

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent GaS Fireplace

Optional Trim Kits Screen Door Kit


Louvre Accent Trim Appliance Model Kit Model
Appliance Model Main Louvre Kit Additional Louvre 33LDVT 33DVSDKG Gold
Polished Brass 36LDVT 36DVSDKG Gold
33LDVT 33DVLMP 33DVLAP 39LDVT 39DVSDKG Gold
36LDVT 36DVLMP 36DVLAP 33LDVT 33DVSDKS Pewter
39LDVT 39DVLMP 39DVLAP 36LDVT 36DVSDKS Pewter
43LDVT 43DVLMP 43DVLAP
39LDVT 39DVSDKS Pewter
Antique Brass
33LDVT 33DVLMA 33DVLAA 33LDVT 33DVSDKB Black
36LDVT 36DVLMA 36DVLAA 36LDVT 36DVSDKB Black
39LDVT 39DVLMA 39DVLAA 39LDVT 39DVSDKB Black
43LDVT 43DVLMA 43DVLAA 33LDVT 33DVSDKR Rustic Bronze
Rustic Bronze 36LDVT 36DVSDKR Rustic Bronze
33LDVT 33DVLMR 33DVLAR 39LDVT 39DVSDKR Rustic Bronze
36LDVT 36DVLMR 36DVLAR
39LDVT 39DVLMR 39DVLAR Filigree Louvre Kit
43LDVT 43DVLMR 43DVLAR
Pewter Appliance Model Kit Model
33LDVT 33DVLMS 33DVLAS 33LDVT 33DVFKB Black
36LDVT 36DVLMS 36DVLAS 36LDVT 36DVFKB Black
39LDVT 39DVLMS 39DVLAS
39LDVT 39DVFKB Black
43LDVT 43DVLMS 43DVLAS
33LDVT 33DVFKS Pewter
Regular Trim Kit 36LDVT 36DVFKS Pewter
Appliance Model Trim Kit
39LDVT 39DVFKS Pewter
33LDVT 33DVRTKP Polished Brass
33LDVT 33DVRTKA Antique Brass 33LDVT 33DVFKG Gold
33LDVT 33DVRRKS Pewter 36LDVT 36DVFKG Gold
33LDVT 33DVRTKR Rustic Bronze 39LDVT 39DVFKG Gold
Adjustable Regular Trim Kit 33LDVT 33DVFKR Rustic Bronze
Appliance Model Trim Kit 36LDVT 36DVFKR Rustic Bronze
36LDVT ADVRTKP Polished Brass 39LDVT 39DVFKR Rustic Bronze
36LDVT ADVRTKA Antique Brass
36LDVT ADVRRKS Pewter Arch/Square Face Kit
36LDVT ADVRTKR Rustic Bronze
39LDVT ADVRTKP Polished Brass
for the 36LDVT
39LDVT ADVRTKA Antique Brass Romanesque - Arch
39LDVT ADVRRKS Pewter 36DVARFKB Black
39LDVT ADVRTKR Rustic Bronze 36DVARFKR Rustic Bronze
Medium Trim Kit 36DVARFKS Pewter
Appliance Model Trim Kit Romanesque - Square
33LDVT 33DVMTKP Polished Brass 36DVSRFKB Black
33LDVT 33DVMTKA Antique Brass 36DVSRFKR Rustic Bronze
33LDVT 33DVMTKS Pewter 36DVSRFKS Pewter
33LDVT 33DVMTKB Black
Marquette - Arch
43LDVT 43DVMTKP Polished Brass
43LDVT 43DVMTKA Antique Brass 36DVAMTKB Black
43LDVT 43DVMTKS Pewter 36DVAMTKR Rustic Bronze
43LDVT 43DVMTKB Black 36DVAMTKS Pewter
Adjustable Medium Trim Kit Marquette - Square
Appliance Model Trim Kit 36DVSMTKB Black
36LDVT ADVMTKP Polished Brass 36DVSMTKR Rustic Bronze
36LDVT ADVMTKA Antique Brass 36DVSMTKS Pewter
36LDVT ADVMTKS Pewter
36LDVT ADVMTKB Black
39LDVT ADVMTKP Polished Brass
39LDVT ADVMTKA Antique Brass
39LDVT ADVMTKS Pewter
39LDVT ADVMTKB Black

10007852 37

Downloaded from www.Manualslib.com manuals search engine


LDVT Series Direct Vent Gas Fireplace

38 10007852

Downloaded from www.Manualslib.com manuals search engine


LIMITED LIFETIME WARRANTY
LDVT Series Direct Vent GaS Fireplace
PRODUCT COVERED BY THIS WARRANTY
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with
an Insta-Flame Ceramic Burner, or standard steel tube burner.
BASIC WARRANTY
CFM Corporation (hereinafter referred to collectively as the Company) • Any part and/or component replaced under the provisions of this
warrants that your new Vermont Castings or Majestic Gas Fireplace/ warranty is covered for six months or the remainder of the original
Stove is free from manufacturing and material defects for a period of warranty, whichever is longest.
one year from the date of purchase, subject to the following conditions • This warranty is limited to the repair of or replacement of part(s) found
and limitations. to be defective in material or workmanship, provided that such part(s)
EXTENDED LIFETIME WARRANTY have been subjected to normal conditions of use and service, after
said defect is confirmed by the Company’s inspection.
The heat exchanger, where applicable, and combustion chamber of
every Vermont Castings or Majestic gas product is warranted for life • The company may, at its discretion, fully discharge all obligations
against through wall perforation. All appliances equipped with an Insta- with respect to this warranty by refunding the wholesale price of the
Flame Ceramic Burner have limited lifetime coverage on the ceramic defective part(s)
burner plaque. Warrantees are made to the original owner subject • Any installation, labor, construction, transportation, or other related
to proof of purchase and the conditions and limitations listed on this costs/expenses arising from defective part(s), repair, replacement,
Warranty Document or otherwise of same, will not be covered by this warranty, nor shall
COMPONENT WARRANTY the Company assume responsibility for same. Further, the Company
will not be responsible for any incidental, indirect, or consequential
CAST IRON: All external and internal cast iron parts are warranted for a damages except as provided by law.
period of three years.
• SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR
Note: On porcelain enamel finished external parts and accessories The LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
Company offers no Warranty on chipping of enamel surfaces. Inspect OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY
all product prior to accepting it for any damage to the enamel. LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR
The salt air environment of coastal areas or a high humidity environment CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC
can be corrosive to the porcelain enamel finish. These conditions can RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM
cause rusting of the cast iron beneath the porcelain enamel finish, STATE TO STATE.
which will cause the finish to flake off. • All other warranties-expressed or implied- with respect to the product,
Dye lot variations with replacement parts and/or accessories can occur its components and accessories, or any obligations/liabilities on the
and are not covered by warranty. part of the Company are hereby expressly excluded.
GLASS DOORS: Glass doors are covered for a period of one year. Glass • The Company neither assumes, nor authorizes any third party to
doors are not warranted for breakage due to misuse or accident. Glass doors assume on its behalf, any other liabilities with respect to the sale of
are not covered for discoloration or burned in stains due to environmental this Vermont Castings or Majestic product
issues, or improper cleaning and maintenance. • The warranties as outlined within this document do not apply to
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be chimney components or other non CFM Corporation accessories used
cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix in conjunction with the installation of this product..
and masonry cleaners may corrode the brass finish. The Company will not • Damage to the unit while in transit is not covered by this warranty but
be responsible for, nor will it warrant any brass parts which are damaged is subject to claim against the common carrier. Contact the dealer
by external chemicals or down draft conditions. from whom you purchased your fireplace/stove (do not operate the
appliance as this might negate the ability to process the claim with the
GAS VALVES: Gas valves are covered for a period of one year
carrier).
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and • The Company will not be responsible for:
mechanical components of the burner assembly are covered for one year.
All steel tube burners are warranted for one year. a) Down drafts or spillage caused by environmental conditions such
as near-by trees, buildings, roof tops, hills, or mountains.
ACCESSORIES: Unless otherwise noted all components and CFM b) Inadequate ventilation or negative air pressure caused by
Corporation company supplied accessories are covered for a period of mechanical systems such as furnaces, fans, clothes dryers, etc.
one year.
• This warranty is void if:
CONDITIONS AND LIMITATIONS a) The fireplace has been operated in atmospheres contaminated by
• This Vermont Castings or Majestic product must be installed or serviced chlorine, fluorine, or other damaging chemicals.
by a qualified installer, preferably NFI or WETT (Canada) certified, as b) The fireplace has been subjected to prolonged periods of dampness
prescribed by the local jurisdiction. It must be installed and operated at or condensation
all times in accordance with the Installation and Operating instructions c) Any damages to the fireplace, combustion chamber, heat exchanger
furnished with the product. Any alteration, willful abuse, accident, or or other components due to water, or weather damage, which is the
misuse of the product shall nullify this warranty. result of but not limited to, improper chimney/venting installation.
• This warranty is non-transferable, and is made to the original owner, d) Any alteration, willful abuse, accident, or misuse of the product
provided that the purchase was made through an authorized supplier has occurred.
of the Company.
IF WARRANTY SERVICE IS NEEDED…
• The customer must pay for any Authorized Dealer in-home travel fees
or service charges for in-home repair work. It is the dealers option 1) Contact your supplier. Make sure you have your warranty,
whether the repair work will be done in the customer’s home or in the your sales receipt, and the model/serial number of your CFM
dealer’s shop. Corporation product.
• If upon inspection, the damage is found to be the fault of the manufacturer, 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK
repairs will be authorized at no charge to the customer parts and/or YOURSELF.
labor.

10007852 39

Downloaded from www.Manualslib.com manuals search engine


Efficiency Ratings
Model EnerGuide Ratings Steady State (%) D.O.E.
Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%)
33LDVTRN 56 77 78 58
33LDVTRP 56 78 79 58
33LDVTEN 63.3 77 78 58
36LDVTRN 55 78 79 58
36LDVTRP 55 79 80 58
36LDVTEN 60.6 78 79 58
36LDVTEP 60.6 79 80 58
39LDVTRN 51.4 76 77 63
39LDVTRP 51.4 77 78 63
39LDVTEN 55.4 76 77 63
39LDVTEP 55.4 77 78 63
43LDVTRN 55.7 76 77 63
43LDVTRP 55.7 77 78 63
43LDVTEN 59.8 76 77 63
43LDVTEP 59.8 77 78 63

CFM Corporation