GE’s Waukesha VGF generator sets offer a compact, fuel- The VGF48 generator set is designed for standby and
flexible package delivering exceptional performance in continuous power applications and is rated at 670-720
prime power, cogeneration, peak shaving and stand-by kWe at 50 Hz (1500 rpm) and 810-860 kWe at 60 Hz (1800
power applications. rpm).
technical data
Waukesha engine P48GL/GLD Dimensions l x w x h inch (mm)
Cylinders V 16 Heat exchanger 208 (5280) x 68 (1720) x 96 (2440)
Piston displacement 2924 cu. in. (48 L) Water cooler 176 (4470) x 68 (1720) x 96 (2440)
Radiator 228 (5790) x 105 (2670) x 136 (3230)
Compression ratio 11:1
Bore & stroke 5.98” x 6.5” (152 x 165 mm) Weights lb (kg)
Jacket water system capacity 58 gal. (219 L) Heat exchanger 24980 (11340)
Lube oil capacity 113 gal. (428 L) Water connection 23000 (10440)
Starting system 24V DC electric Radiator 30200 (13700)
Heat to Intercooler Btu/hr x 1000 (kW) 527 (154) 359 (105) 566 (166) 397 (115)
Heat to Radiation Btu/hr x 1000 (kW) 146 (43) 136 (40) 144 (42) 134 (39)
Total Exhaust Heat Btu/hr x 1000 (kW) 2340 (686) 1800 (528) 2380 (697) 1850 (542)
Induction Air Flow scfm (Nm /hr)
3
2478 (3809) 2002 (3077) 2425 (3724) 1975 (3039)
Intake/Exhaust
Exhaust Flow lb/hr (kg/hr) 10805 (4901) 8728 (3959) 11070 (5020) 9030 (4096)
System
Exhaust Temperature °F (°C) 839 (448) 802 (428) 841 (449) 798 (425)
Radiator Air Flow scfm (m3/min) (radiator cooling) 63750 (1805) 73468 (2080) 63750 (1805) 73468 (2080)