Hanix S&B480/580 codes

Error display in controller Cluster error lamp Error content Controller check details Machine behavior when an error occurs Response when an error occurs
Translation by andyfromm.yt@gmail.com At startup Always (while driving)
PS Flashing Power supply voltage abnormality Is it 9.5-16V Wait for voltage recovery at all work machines and turning stop (inoperable)
CP Flashing CPU internal and peripheral LSI error Is there anything abnormal? --- All work machines and turning stop (cannot operate)
SP Flashing Pattern switch Wire break/short circuit Isn't it broken? --- All work machines and turning stop (cannot operate)
H1 J/S Wire break/short circuit right front/back
H2 J/S Wire break/short circuit right left/right
H3 J/S Wire break/short circuit left front/back
H4 Flashing J/S Wire break/short circuit right left/right Is there a wire break/short circuit? All work machines and turning stop (cannot operate)
F1 J/S Wire break/sensor error right front/back
F2 J/S Wire break/sensor error right left/right
F3 J/S Wire break/sensor error left front/back
F4 Flashing J/S Wire break/sensor error left left/right Is the output of J/S centered? Wait for J/S to become neutral with all channels stopped (inoperable) even if the center is off even for 1 channel (operation is not possible unless the center of all channels is out)
J1 The relationship between the output of J/S and the micro switch is abnormal right front/back
J2 The relationship between the output of J/S and the micro switch is abnormal right left/right
J3 The relationship between the output of J/S and the micro switch is abnormal left front/back
J4 Flashes at startup Constantly lit The relationship between the output of J/S and the micro switch is abnormal left left/right Is the micro switch OFF when the output is in the center (whether it is ON for 1 second or longer)? Is the micro switch ON when the output is operating? At startup: J/S lever is neutral, but if the micro switch is on and it continues for 1 second or longer, all work machines and turning stop (operation impossible) Always: Although the J/S lever is being ope
S1 Solenoid coil wire break/short circuit boom
S2 Solenoid coil wire break/short circuit bucket
S3 Solenoid coil wire break/short circuit arm
S4 Flashing Solenoid coil wire break/short circuit swing Is there a wire break/short circuit? --- At startup: All work machines and turning stop (inoperable)
L1 Differential transformer wire break/short circuit boom
L2 Differential transformer wire break/short circuit bucket
L3 Differential transformer wire break/short circuit arm
L4 Flashing Differential transformer wire break/short circuit swing Is there a wire break/short circuit? All work machines and turning stop (cannot operate)
C1 Spool center abnormal boom
C2 Spool center abnormal bucket
C3 Spool center abnormal arm
C4 Flashing Spool center abnormal swing Is the spool returning to the center? --- All work machines and turning stop (cannot operate)
E1 Servo error detection boom
E2 Servo error detection bucket
E3 Servo error detection arm
E4 Lights up (safety side) Flashes (dangerous side) Servo error detection swing --- Is the spool moving according to the J/S command value? If a servo error on the dangerous side (when the valve spool strokes more than the J/S command
Bysignal) occurs on of
"Fault diagnosis channel O1 control
electrical as well,system"
all work machines and turning will stop. Servo error on the safe
SL --- Safety lever up Is the lever raised? All channels stopped (inoperable) Turn on the safety lock lever
SO Flashing Check the detection circuit for power transistor short circuit or solenoid coil wire break/short circuit Is there anything abnormal? --- All work machines and turning stop (cannot operate)

"H" Codes J/S Wire break/short circuit


"F" Codes Center abnormality
"J" codes Abnormal relationship between J/S output and micro switch
"S" Codes Solenoid coil wire break/short circuit
"L" Codes Differential transformer wire break/short circuit Differential transformer is on the end of the manual spool valves
"C" Codes Spool center abnormality
"E" Codes Servo error

Pattern Switch
Position Style

ISO Hanix, Yanmar, Kubo, Ishikawajima


A SCM, Komatsu, Sumitomo, Furukawa, Hitachi
B Steel
C Mitsubishi
D J&D
E Middle road
F Old hanics

*Please change the lever pattern with the starter switch "OFF". Switching cannot be done in the "ON" state.