Part 3:
A Guide to Installing
Unvented Attics in Canada
Designers, builders, and homeowners are seeking SPF provides insulation and an air barrier on the
options to build more energy-efficient, resilient, underside of the roof deck or sheathing, which limits
affordable, and comfortable homes. Building air and moisture flow through the assembly. Because
unvented attic (UVA) assemblies, instead of a attic air is maintained well above the dew point,
conventional vented attic, provides a unique solution attic venting is not required. Exterior walls (at gable
to improve energy efficiency and helping avoid the ends) of the attic are also required to be insulated
ingress of moisture, fire, embers, and other extreme and air sealed resulting in an attic space completely
weather in attics while adding flexibility in terms of encapsulated in SPF.
design options.
Because the interior space of an UVA is inside the
An UVA assembly can allow for the normally thermal envelope, insulating the floor of the attic is
overlooked open attic space to become usable not recommended. The result is a conditioned attic
occupied space (with appropriate interior finish) space is contained within the insulated, air-sealed
or a conditioned service space providing a more building envelope. If used as occupied living space,
hospitable environment for placing and servicing the attic may be directly conditioned with HVAC and
electrical fixtures, mechanical equipment, water finished accordingly. However, if used only for the
lines, ductwork, and storage. purposes of keeping the ductwork and mechanical
systems in conditioned space, the attic may be
Spray polyurethane foam (SPF) provides one of the
indirectly conditioned; in this case conditioning is
most proven options for creating an UVA assembly.
provided by heat exchange through ductwork and
Builders have created hundreds of thousands of
mechanical equipment, and via duct leakage and via
UVAs using SPF in all North American climate
heat exchange with the living spaces below though
zones. To create an UVA, SPF is applied directly to
the uninsulated attic floor. In either case, UVA
the underside of the roof deck or sheathing and the
assemblies move the insulation and air barrier from
adjacent structural roof trusses or rafters - similar
the floor of the attic to the roofline.
to the way SPF insulation is applied in walls. In UVAs,
Advantages of Unvented Attic Assemblies floor for pot lights, exhaust fans, piping, and
with Spray Foam HVAC ducting and equipment do not impact the
integrity of the thermal envelope and they aid the
UVA assemblies, insulated and air sealed using SPF,
indirect conditioning process for the attic as well.
offer numerous performance advantages versus
vented attics: • Freeze Protection for HVAC and Plumbing in the
Attic: Moving the thermal envelope to the roofline
• Fewer Thermal Envelope Penetrations: The
helps to ensure service water connections,
roof plane becomes the top edge of the building
condensate lines, pumps and other equipment
envelope for the home. At this location, there
located in the attic are no longer in danger of
are fewer penetrations to make airtight than at
freezing. The need for associated heat tracing,
the attic floor. In the winter, the roof sheathing
maintenance, repair, or upgrading activities can
and shingles are protected from heat loss and
be virtually eliminated.
moisture by the SPF. As a code-compliant air
impermeable material, SPF can encapsulate • Avoidance of Placing Ducts in Unconditioned
framing as well as sheathing to deliver a Spaces: UVA assemblies can help minimize the
continuous insulation layer and air barrier. energy losses associated with leaky ductwork
in the attic. UVAs create a more hospitable
• Simplified Installation: UVA assemblies
environment for ductwork making it possible
accommodate roof plans that are complex or
to easily condition rooms in remote corners of
difficult to vent properly. Homes with limited
the home with duct accessibility challenges. For
side-yard setbacks, roofs with complex slopes,
example, “bonus rooms” over garages can be
and gables can be difficult to vent properly. UVA
conditioned from the UVA above thereby avoiding
assemblies can simplify or eliminate complex
potential heat loss, occupant discomfort, and
insulation, air sealing, and vapour barrier
safety issues associated with running ducts
requirements that may be problematic in the
through garages and/or other exposed locations.
field. Continuous application of air-impermeable
insulation at the roofline and exterior walls • Simplified Creation of Additional Occupied Space:
reduces the potential for compromises to the The attic space can be turned into occupant space
thermal envelope. Because the roofline is part which potentially enhances the value of the house.
of the thermal envelope, penetrations in the attic
• HVAC Location Options are Increased: Furnaces
with a sealed combustion (direct venting) systems
and ventilation systems, can be located in a
hospitable attic environment without fear of
freezing condensate lines. Ductwork associated
UVA assemblies, sometimes with such equipment would not be subject to
called unventilated, extreme exterior temperatures and duct leakage
compromising its performance.
“cathedralized” attic roof assemblies,
typically feature a sloped roof system. • Reduced Exposure to Extreme Weather: UVA
assemblies also offer protection from the ingress
However, UVA assemblies can be created
of blowing snow, rain, and burning embers
with cathedral ceilings or with flat roof (in areas where wildfires are a risk). In parts
of the country where the construction abuts
assemblies as well.
the wildland-urban interface, burning embers
entering vented attics can be a significant risk to
homeowners and their insurers. In some forested
regions of North America, vented attics are not
allowed because of the risk of attic fires from is intended to provide
burning embers. detailed guidance on how
to successfully build an
• Cost Savings Related to Provision of Attic Venting:
UVA using SPF such that the
UVA assemblies potentially offer construction
rationale and practical detailing of such designs are
cost savings because attic venting detailing can be
better known.
eliminated or significantly reduced in scope.
One rationale for Canadian code acceptance is the
Code Considerations for Unvented Attics extensive experience with UVA construction in the
US. The U.S. model building code – the International
The National Building Code (NBC) and Provincial
Residential Construction Code has featured UVA
Codes modeled on it, specifies vented attics in
assemblies since 2006, with some state approvals
Sentence 9.19.1.1.1 but allows unvented attics as a
occurring several years prior. The requirements
specific exception:
apply to all U.S. climate zones including cold and
“Except where it can be shown to be unnecessary, very cold climate zones (e.g. Alaska and mountain
where insulation is installed between a ceiling states in the Pacific Northwest). This has given
and the underside of the roof sheathing, a space rise to extensive experience with successful UVA
between the insulation and the sheathing, and assemblies, sealed with SPF in all North American
vents shall be installed to permit the transfer of climate zones—they have been built by the thousands
moisture from the space to the exterior”. annually in residential and commercial buildings
across the United States. In Southwest U.S. the UVA
NBC Appendix A provides a discussion of situations
assembly is advantageous since many buildings
where venting might be unnecessary, however, the
don’t have basements—UVA’s are a straightforward,
structure of this part of the Code assumes that the
more energy-efficient solution for dealing with
default will be a vented attic assembly. This makes
performance inefficiencies associated with locating
approval of UVA assembly subject to the approval of
HVAC equipment and ductwork in the attic.
the Authority Having Jurisdiction (AHJ). Designers
and builders need the approval of their building In Canada, UVA assemblies are not as well-known
official BEFORE proceeding. due to the difficulty of obtaining approvals without a
prescriptive code clause. Nevertheless, numerous
The wording “where it can be shown to be
UVA assemblies are found across Canada as
unnecessary” suggests that it is necessary for
well. Designers and builders have found several
someone to demonstrate there is no need for
key design features that must be considered to
venting the attic. Some progressive jurisdictions
successfully implement UVA assemblies. Use of
have examined the issue and have arrived at their
air-impermeable insulation, such as SPF, and
own determinations of when UVA assemblies are
proper assembly design are important to ensure the
appropriate. Other jurisdictions require a designer
successful construction of an UVA assembly. SPF is
(architect or engineer) to take responsibility and
particularly suited to application in UVA assemblies
approve the UVA assembly. Unfortunately, some
because it adheres to surfaces where it is sprayed,
jurisdictions are not prepared to allow the use of
meet the required R-values, and can help form an
UVA assemblies in their jurisdiction due to a lack
effective, continuous Air Barrier and Vapour Barrier
of guidance on how they should be built. This guide
in areas where it is professionally applied.
UVA Assembly Key Aspects and Details
The key features of UVA assemblies featuring
SPF are:
1,4 Rudd (2004). Unvented-Cathedralized, 6 Less, Walker & Levinson (2016). A Literature
Conditioned Attics: A Comprehensive Update. Review of Sealed and Insulated Attics—
Building Science Corporation. Westford, MA. Thermal, Moisture and Energy Performance.
Lawrence Berkeley National Laboratory,
2 Straube, Smegal & Smith (2010). Moisture-Safe
Berkeley, CA.
Unvented Wood Roof Systems. The University
of Waterloo and Building Science Corporation. 7 Prevatt (2007). “Wind Uplift Behavior of Wood
Waterloo, ON. Roof Sheathing Panels Retrofitted with Spray-
applied Polyurethane Foam”, University of
3 Schumacher (2007). Unvented Roof Assemblies
Florida, Gainesville, FL.
for All Climates. Building Science Consulting.
Westford, MA. 8 Schumacher (2016). Research Summary – Field
Performance of ocSPF-insulated Unvented Roof
5 Lstiburek (2006). Understanding Attic
Assemblies in the Climate of Vancouver, British
Ventilation. Building Science Corporation.
Columbia, Canada. Building Science Consulting
Westford, MA.
Inc.,Waterloo, ON.