You are on page 1of 1

EFFECTIVE:

DIMENSION PRINT PRINT:


12-MAY-14 WITH STYLE "D" BRACKET 16-A-263
SUPERSEDES: FRAME: 5807, 5809, 5811SD SHEET:
16-MAY-13 BASIC TYPE: J 1 OF 1

C P
AG AH AB
ES AC BF
T 8 HOLES
BE AJ

O
AK

BD AF
U D

BB E DH
K1 K2 G
J
BS BC
2E SEPARATE OUTLET
2F3 BA BOX FOR WINDING
A ACCESSORIES AS
H 2F2 AA SIZE REQUIRED
HOLES CONDUIT DM SIZE CONDUIT
2F

B AD

AD

ALL DIMENSIONS ARE IN INCHES


D E 2E G H4 U
A -.06 +.05 J K1 K2 O P T
±.03 -.001
28.50 14.50 11.50 23.00 2.00 1.09 5.00 10.00 5.00 30.06 31.13 3.19 3.375

AK BB BD ES SQ
AH AJ BA BC BE BF BS DH
-.005 MIN MAX MIN KEY
6.75 22.000 18.000 10.00 .25 0 24.63 .88 .81 3.91 3.91 5.25 .88

HP VOLT AA AB AC AD AF DM
THRU 500 460 3-1/2 NPT 26.13 20.63 - 8.06 3/4 NPT
501 & UP 460 3-1/2 NPT 32.38 23.75 3.00 10.94 3/4 NPT
ALL 2300 3-1/2 NPT 26.13 20.63 - 8.06 3/4 NPT
ALL 4000 3-1/2 NPT 27.13 21.63 - 10.00 3/4 NPT

2F 2F2 2F3
FRAME B C AG
±.03 ±.03 ±.03
5807 29.50 58.50 25.00 22.00 20.00 51.75
5809 36.50 65.50 32.00 28.00 - 58.75
5811 44.50 73.50 40.00 36.00 - 66.75

1: ALL ROUGH DIMENSIONS MAY VARY BY .25" DUE TO 3: CONDUIT BOX CAN BE LOCATED ON EITHER SIDE AND
CASTING AND/OR FABRICATION VARIATIONS. OPENING MAY BE LOCATED IN STEPS OF 90 DEGREES
IHP_DP_NMCA (MAR-2011) SOLIDEDGE

2: MOTOR MUST BE FOOT MOUNTED OR SUPPORTED. REGARDLESS OF LOCATION. STANDARD AS SHOWN


MUST NOT BE FLANGE SUPPORTED ONLY. WITH CONDUIT OPENING DOWN.
4: QTY-8 HOLES ON 5807 AND QTY-6 HOLES
ON ALL OTHERS.
TOLERANCES
FACE RUNOUT .007 T.I.R.
PERMISSIBLE ECCENTRICITY
OF MOUNTING RABBET .007 T.I.R.
PERMISSIBLE SHAFT RUNOUT .003 T.I.R.

ISSUED BY
R. KING
INFORMATION DISCLOSED ON THIS DOCUMENT APPROVED BY
Nidec Motor Corporation IS CONSIDERED PROPRIETARY AND SHALL NOT BE
R. SCHMIDT
REPRODUCED OR DISCLOSED WITHOUT WRITTEN
St. Louis, Missouri CONSENT OF NIDEC MOTOR CORPORATION

You might also like