You are on page 1of 1

Civil and Geotechnical Laboratory

SBU MINERAL PT. SUCOFINDO


Jalan Arteri Tol Cibitung No. 1
Cibitung 17512

Compressive Strength

Ref. : SNI 1974 : 2011 Commencement date : 01/08/2023


Job No. : MIN/1106/50/001733/07/2023 Completed date : 09/08/2023
Client : PT TIRTA WIJAYA KARYA Sample prepared by : MJ&JY
Client sample ID : EAC-001 K350 (1-5) Tested by : MJ&JY
Lab. Sample ID : KGM 141.07.23-1 Checked by : RF

Determination of Cubic / Square Sample

Surface
Test age Weight Diameter Height Load Compressive strength
Sample ID Testing date area

days gr cm cm cm2 kN MPa


EAC - 001 - K350_1 2/8/2023 14 12577 15.10 30.16 179.08 761.70 42.53
EAC - 001 - K350_2 2/8/2023 14 11483 15.10 30.12 179.08 490.80 27.41
EAC - 001 - K350_3 2/8/2023 14 11820 15.15 30.14 180.27 515.40 28.59
EAC - 001 - K350_4 2/8/2023 14 12450 15.18 30.20 180.98 744.28 41.12
EAC - 001 - K350_5 2/8/2023 14 12335 15.21 30.18 181.70 1,091.20 60.06
EAC - 001 - K350_1 9/8/2023 21 12297 15.05 29.85 177.99 696.21 39.12
EAC - 001 - K350_2 9/8/2023 21 12351 15.10 30.08 179.17 602.14 33.61
EAC - 001 - K350_3 9/8/2023 21 12542 15.15 30.07 180.35 715.94 39.70
EAC - 001 - K350_4 9/8/2023 21 11716 15.14 30.08 179.93 528.54 29.37
EAC - 001 - K350_5 9/8/2023 21 12426 15.18 30.14 181.08 697.55 38.52

You might also like