ats XL ENGINEERING 53 & 54, SIDCO Industrial Estate, Thuvakudy, Truchirappali - 620 015
_ . Phone : (0431) 2500007, Fax : (0431) 2501701,
TEST SERVICES Nobile : 94431 51948, 99655 51968,E-mail: xlengglab@gmail.com
TEST REPORT
Report No : XLE / 0679 Date: 03.03.2022
Issued to. : M/s, ANPAM ENGINEERING, |
9/1, A-7, Kumaramangalam Industrial Estate, Mathur ~ 622 515. Pudukkotai
TEST PARTICULARS
Testing Standard ‘ASME See IX “|
Name of the Qualification PROCEDURE QUALIFICATION RECORD |
Name of the welder : Mr. D. KAMARA
| Welding process :SMAW
Welding Position IG |
Identification No AE / WPS / 006 / 2022. |
Heat Treatment rNA |
| ; TEST MATERIAL DETAILS -
Material | Specification —_| Size | ay Welding Consumables Used
| SA387 Gr.22 C2 +
[__ Plate to Plate | "sa 387 Gr.22 C12
Pl; 10x300x300 mm | 01 | SMAW: E9018-B3, MAILARC-2CR
‘TEST RESULTS
I) Transverse Tensile Test: (Reference range of TS: $15 N/mm*(min)) As per QW 462.1(a)
| ]
Thick Width CSA TL TS
Identification mmm nm para ry Nae ‘Type of fracture & Location
AE/ WPS / 006/T1 9.72 19.98 194.21 110.37 568.34 Ductile fracture / Parent Metal |
| AE/ WPS / 006 /T2 9.54 | 20.04 191.18 | 109.75 574.08 Ductile fracture / Parent Metal
I1) Transverse Bend Test: Mandrill Dia.: 4t ( 40 mm ) Angle of Bending @180” As per QW 462.3(a)
Identification Type of Bend ‘Observation [Remark
| AE/ WPS / 006 / FBI Face Bend ‘No Open discontinuity in the Weld and HAZ | Satisfactory
‘AE / WPS / 006 / FB2 Face Bend ‘No Open discontinuity in the Weld and HAZ Satisfactory |
| AE/ WPS /006/ RBI Face Bend | No Open discontinuity in the Weld and HAZ | Satisfactory |
‘AE/ WPS / 006 / RB2 Face Bend No Open discontinuity in the Weld and HAZ | Satisfactory
fA NAN
ENGI ZABS
XL ENGINEERING
‘TIRUCHTRAPPALLI-15