You are on page 1of 4

PERSONAL DATA:

Name: Arun Rajkumar.R


Position: Service Engineer Nationality Indian
Date of Birth: 27, July 1990 Age 26

YEARS OF EXPERIENCE:

Total years of Exp.: 5 Years

EXPOSURE TO:

ARAMCO SABIC SEC RC Other


Yes Yes Yes - Yes

AREAS OF EXPERIENCE:

Installation Testing Commissioning Design Supervision Project M Maintenance Other


Yes Yes Yes - Yes - Yes Yes

EDUCATIONAL QUALIFICATION:
No Degree Discipline University City/Country Date
1.0 Bachelor of Electronics and Anna University Chennai/India 2011
Engineering Communication engineer
.

CONVERSANT IN

 Testing and Commissioning of Electro-Mechanical., Static & Numerical relays.


 Strong Knowledge in Relay Configuration, Testing and commissioning of SIEMENS PSD02 relays.
 Modification & Configuring Protection schemes as per requirement during Commissioning.
 Testing and Commissioning of Transformer, Circuit breaker, CT, VT, CVT, Reactor, Isolators, Bus bars, Cables,
Protection Panels and Protection relays.
 Preparation & Review of Schematic Drawing, Supervision of Installation, Testing & Commissioning of all
electrical equipment.
 Thorough in Review/reading & Preparing Elect. Schematic Drawing.
Present Experience as a Service Engineer in RISAS, SAUDI ARABI
 Performs transformer testing and commissioning up to 315MVA 400KV/230KV/33KV power
transformer.
 Performs Setting & Testing of Siemens, ABB Over Current, Earth fault, Differential and Distance
Protection Relays.
 Performs and calibration of power meters and power quality meters.
 Performs the measurement of inrush current and harmonic measurements.
 Performs Testing of EATON ATC300+ & 800+automatic transfer switch controller.
 Pre-Commissioning & Testing of Medium Voltage Distribution Transformers., Power
Transformers/Current Transformers/Voltage Transformers/Instrument Transformers.
 Pre-Commissioning & Testing of MCCB, MCB, ACB, Switch Rack, RMUs, LV Switchgear, MV
Switchgear and 220KV Control and relay panel.
 Pre- Commissioning & Testing of Low/Medium Voltage Power Cables, Medium voltage Electrical
Motors .
 Performs system start-up and commissioning services as required.
 Troubleshooting of MV switchgear.
 Dismantling, Shifting, Installation & Testing and commissioning of 220KV outdoor switchyard
equipment and relay panels.

Projects Worked:
1. Saudi Aramco 10.0KVA, 13.8KV/480V Transformer testing and Commissioning at Jubail.

Customer: KASS international Ltd. Client: Saudi Aramco

Responsibilities:
i) Co-ordination with Aramco PMT, PID, POD.
ii) Testing and commissioning of Transformer.

2. Saudi Aramco Testing and Commissioning of WELL#63, NGL Reciever, sender and GOSP switchracks
and Meters, Current transformers, Voltage Transformer testing and commissioning, 75KVA 13.8KV/480V
Transformer testing and Commissioning at Shaybah.

Customer: Diversified line petroleum service Est. Client: Saudi Aramco

Responsibilities:
i) Co-ordination with Aramco PMT, PID, POD.
ii) Testing and commissioning of Switchrack and transformer Testing.

3. Saudi Aramco Testing and Commissioning of Pump control circuit and Testing of MCCB, Voltage
Transformer, Current Transformer, Over load Relay, Timers at Dareen Port, Qatif

Customer: Al-Fanar Client: Saudi Aramco

4. Saudi Aramco Testing and commissioning of MV 4.16KV MCC

Customer: ALBARGASH Client: Saudi Aramco.

5. Testing and commissioning of 13.8KV MV switchgear at Building 82.6

Customer : AQESA Client : KFMC


6. Testing and commissioning of 13.8KV MV switchgear at Building 30

Customer : AQESA Client : KFMC

7. Testing and commissioning of Magnum Breaker at SABIC Jubail.

Customer : AQESA Client : SABIC RNT

8. Long term shutdown Project working in Dismantling of old LV switchboard, Installation of new LV
switchboard, Testing and commissioning of LV switchboard at KFMC Dammam.

Customer: AQESA Client : KFMC

9. Testing and commissioning of heater panel

Customer : OGEI Client : HUNTING

10. Testing and commissioning of Industrial water heater at KAPSARC in Riyadh

Customer : ISSAM KABBANI Client : Saudi Aramco

11. Serving and Testing & Commissioning of 13.8KV MV Switchgear in SECO Khobar.

Customer : Arabian Energy system general contracting Est. Client : SECO

12. Motor Protection relay configuration and testing of SIEMENS Make 7SK8031

Customer: SWCC Client : SWCC

Experience in India

Testing and Commissioning Engineer


DNJ ENERGY June 2014- May 2015

 Testing and commissioning of LV system to 400KV systems.


 Testing & Commissioning of Distribution Transformers /Current Transformer/Voltage
Transformers/Instrument Transformers
 Testing of Power Panels, ampere meters/ Voltage meters and Bus Bars
 Installed bus bar in distribution side according to the demand to ensure necessary protection with
switches and fuses
 Performed cable laying and routing on HT and LT Sides.
 Performed Quality control jobs on transformers and switch gear and submitting the reports to the
concerned higher officials.
 Performed load calculations by using CT and PT and submitting the results to the concerned engineers
for selections and approvals.
 Transformer differential stability.

Testing and Commissioning Engineer


TESTCOM June 2013 - May 2014.

 Scheme checking of Protection Control Panel in 66/11KV Substation.


 Performs testing of 20MVA 66/11KV power Transformer.
 11KV MV switchgear testing and commissioning.
 Relay Configuration and testing for Overcurrent and Earth fault Protection, Busbar Differential protection,
Bay Control Unit.
 Earth resistance testing.
 Performs the Battery charging and discharging test.
 Performs the tan delta testing of 400KV Switchyard equipment.

Electrical Engineer
Larsen and Toubro Ltd, Manikgarh Cement Plant April 2011 - May 2013.

 Preventive maintenance
 Operation and maintenance of electrical systems.
 Coordination with the client technician and labors.
 Planning & Designing
 Calibration as per Schedule
 Doing Projects in PC based and PLC Based machines.
 Manage project schedules and budgets, and obtain permits for operations.
 Make engineering calculations in connection with field and office assignments.
 Investigate problems and recommend solutions.
 Ensure compliance with safety requirements and standards procedures.
 Prepare requests for proposals and evaluate bids.

TESTING EQUIPTMENT HANDLED:-

TRANSFORMER RATIO METER – TTR 330

TRANSFORMER OHM METER – MTO 210

PRIMARY CURRENT INJECTOR – RAPTOR

PRIMARY CURRENT INJECTOR – PHENIX

PRIMARY CURRENT INJECTOR – MS-2A

INSULATION TESTER – MIT 520

AC & DC HI-POT TESTER- PHENIX, ELTEL

CONTACT RESISTANCE METER – DLRO10HD

OMICRON-CMC356, DOBBLE (Relay testing)

OMICRON-CPC100, CPTD1

MEGGER KIT- Tan delta testing

HISAC ULTIMA- DCRM & Timing of BREAKER

Employment History:
Rakaez Industrial Supplies and Services-RISAS (Damman ksa) June 2015 -Present
DNJ Energy – Dubai (UAE) June 2014 to May 2015
TESTCOM (India) June 2013 to May 2014
Larsen & Toubro Ltd (India) April 2011 to May 2013

You might also like