You are on page 1of 8

As Told by

Our
Customers

Reasons for Installing


Application Advantages Edition
SJ Series Static Eliminators
We have collected comments from customers who have installed KEYENCE static eliminators.

1 Peace of Mind
“The SJ Series has a safe design, so anyone can use it with peace
Customer
comment of mind. And the self-diagnosis function is always running during
operation, which also provides us with peace of mind.”

The built-in high-voltage power supply eliminates concerns regarding accidents.


KEYENCE’s bar- and fan-type units have a high-voltage power supply built into the unit, so the only external wiring required is
a 24 VDC cable. The spot type has a high-voltage power supply between the controller and the ion generator, but the
double-shielded structure ensures that the high-voltage core wires are not exposed when minor damage occurs, such as
damage to the coating.
Also, even in the rare case that electrical leakage appears likely due to severe wire breakage or damage, all models are
equipped with an abnormal discharge detection function, which immediately detects electrical leakage and stops the power
supply. This means that all models are designed to provide peace of mind.

Built-in high-voltage power supply Abnormal discharge detection function Double-shielded wire

Core wire

Primary shield

Secondary shield

Does not unexpectedly become an electrostatic charging unit.


When the electrode probes become dirty, the amount of ions is reduced and the ion balance becomes poor. If a static
eliminator like this is continuously used, not only will it not be possible to eliminate static electricity, but the target may even
be charged with static electricity. The SJ Series has a function that monitors the ion generation status and outputs an alarm
when the generation status worsens.

Drop in the ion level (decrease in the amount of + ions)

The high quality lowers the risk of sudden failures.


The SJ Series is made in Japan* with great attention to quality.
It is manufactured at factories that fully meet all quality standards and is inspected prior to shipment.
* Excluding some controllers and cables. All high-voltage power supplies, which are related to safety, are made in Japan.

2
2 Easy to Understand
“The monitor function is easy to understand. This makes it easy to
Customer
comment understand the current status and make reports on the operating
status.”

The electrostatic charge monitor makes it easy to perform checks.


The SJ Series comes standard-equipped with an ion balance monitor, which makes it possible to understand at a glance how
much positive or negative electrostatic charge the target workpiece has.
This indicates the static electricity elimination status.

During normal operation

Example: The target has a + electrostatic charge.

Self-diagnoses the error status.


The SJ Series uses an automatic self-diagnosis function to constantly monitor for three types of errors.
When an error is detected, it is displayed with the LEDs on the main unit and is indicated with an external output.
Monitoring this external output makes it possible to perform centralised management of multiple static eliminators.

Alarm Cleaning alarm Condition alarm

This is used to monitor drops in


When internal circuit damage or This is used to monitor the effect
the amount of ions that are
an abnormal discharge occurs, of instability in the installation
generated due to dirt affixing to
the high-voltage power supply is environment on the static
the electrode probes or the
interrupted. electricity elimination.
electrode probes wearing out.

3
We have collected comments from customers who have installed KEYENCE static eliminators.

3Customer
Easy to Install
“With conventional products, we had a rough time adjusting static
eliminators for each worksite. This is not the case with the SJ Series,
comment
so we can have anyone make adjustments as necessary.”

 here is no need to perform initial adjustments, so even new users can install the
T
SJ Series.
The I.C.C. function, which is installed on all SJ Series units, automatically makes adjustments to obtain the optimal static
electricity elimination status.
In other words, there is no need to perform the initial adjustments when the unit is installed. This also allows those who are
not familiar with static eliminators to easily install the SJ Series.

Conventional SJ

“I have to measure “I just turn


multiple points and the power on.
adjust the voltage.” That’s all!”

 he built-in high-voltage power supply means that the user does not require
T
installation know-how.
For types whose ion generator and high-voltage power supply are separate, it is necessary for an experienced user to install
the cable that connects these devices together. This is due to the need to implement safety measures. Failing to do so poses
a risk of accidents.
With the SJ, there is no need to worry about this work. Anyone can easily install the SJ.

Ion generator

Conventional For safety, it is necessary to


perform wiring in a manner
High-voltage that guarantees the insulation
power supply of the components.

SJ
Ion generator
24 V power
supply There is no need to make
designs for safety during wiring.

4
4Customer
Peace of Mind
When Exporting
“When we had problems at worksites, it was difficult to troubleshoot
the issue over the phone because static electricity is invisible.
comment
KEYENCE’s global service network provides us with peace of mind.”

 EYENCE’s global service network provides immediate support in the rare case
K
that a problem occurs.
KEYENCE offers service all over the world. This provides peace of mind even when shipping devices equipped with static
eliminators to other countries.

KEYENCE KEYENCE
(UK) INTERNATIONAL
LIMITED (BELGIUM)
KEYENCE CANADA INC. NV/SA
KEYENCE
DEUTSCHLAND GmbH
KEYENCE
KEYENCE CORPORATION FRANCE SAS KOREA KEYENCE CO., LTD. KEYENCE
KEYENCE
OF AMERICA ITALIA KEYENCE (CHINA) CO., LTD. CORPORATION
S.p.A.
KEYENCE (HONG KONG) CO., LTD. KEYENCE TAIWAN CO., LTD.
KEYENCE (THAILAND) CO., LTD. KEYENCE VIETNAM CO., LTD.
KEYENCE MEXICO
S.A. DE C.V. KEYENCE INDIA PVT. LTD. KEYENCE PHILIPPINES INC.
KEYENCE (MALAYSIA) SDN BHD
KEYENCE SINGAPORE PTE LTD.
PT. KEYENCE INDONESIA

KEYENCE BRASIL

Head Office

WWL1_1037

Total support
KEYENCE provides detailed support for implementing appropriate countermeasures for static electricity and particles, which
are invisible.

Seminars covering static electricity Free of


and cleaning charge
•These seminars provide detailed explanations and are
designed for small groups. They can be used as study
sessions for teams that want to make improvements
and implement countermeasures for failures and as
training programs for new employees.
•As a lecturer, KEYENCE will dispatch a certified sales
technician who has received specialised training on the
topic of the seminar.

Free of
On-site diagnosis charge
KEYENCE will actually measure the static electricity
present on your worksite and suggest the best static
electricity countermeasures.
This service quantifies the static electricity and provides
suggestions for effective countermeasures, so we are
confident that anyone who takes advantage of this
service will be satisfied with the results.

5
SJ Series Overall Advantages Customer
comments

Peace of Mind
The SJ Series has a safe design, so anyone can use it with peace
of mind.
And the self-diagnosis function is always running during
operation, which also provides us with peace of mind.

Reduced Costs
We were able to reduce the number of installed units.
We were also able to reduce the takt time.

Easy to Understand
The monitor function is easy to understand.
This makes it easy to understand the current status and make
reports on the operating status.

Reduced Man-hours
We were able to greatly reduce the man-hours we spend performing
maintenance.
We’ve assigned the time we saved to other important work.

Easy to Install
With conventional products, we had a rough time adjusting static
eliminators to match each worksite.
This is not the case with the SJ Series, so we can have anyone
make adjustments as necessary.

Makes the Design Stage Easy


A wide range of different types of static eliminators is available to select from.
All the types have the same functions, which makes the design stage easy.

Peace of Mind When Exporting


When we had problems at worksites, it was difficult to troubleshoot
the issue over the phone.
KEYENCE’s global service network provides us with peace of mind.

6
MEMO

7
Introduction to Related Products

Sensing ionisers Electrostatic sensors

Bar type SJ-H Series

Optimal static elimination capability Industry-first simultaneous measurement of


that enables performance in a wide static electricity and humidity
variety of situations such as static Best-in-class high-precision/wide-range measurement
elimination when no air blows and
when the air flow rate is very large
Hand-held type SK-H050

Laser pointer to identify the reference distance


Blower type SJ-F2000 Series Equipped with a charge monitor function

Ultra-high-speed static
elimination over a wide area
with a high-precision In-line type SK-050/1000
ion balance of ±5 V
over the entire area Ultra-compact sensor head
Supports a variety of open field networks

Spot type SJ-M Series

A rich lineup of sensor heads


with 8 types to select from

www.keyence.com

Copyright (c) 2017 KEYENCE CORPORATION. All rights reserved. SJOperationReason-WW-TG-GB 1087-1 600O19

You might also like