GAS

NITROGEN GENERATOR
NS

Technical Data

Pressure: 10 or 12 bar
Dewpoint: ≤ -40

Features & Benefits


High flow, low air to nitrogen ratio.
Modular design.
Expandable on location.
Siemens PLC S7
Oxygen Analyser (optional)
Flow Control (optional)
% and PPM versions.

Ultrafilter offers very economical Nitrogen Production Flow (Nm³/h)


nitrogen (N2) generators and systems.
Model 10 50 100 500
0,1% 0,5% 1% 2% 3%
Ultrafilter Nitrogen generators work ppm ppm ppm ppm
by PSA principle (Pressure Swing NS-7 2,2 2,9 3,5 4,8 5,7 8,3 10,0 12,2 13,1
Adsorption). High reliability, low NS-14 4,4 5,8 7,0 9,6 11,4 16,5 19,8 24,3 26,1
operating costs and long service life, NS-21 6,6 8,7 10,5 14,4 17,0 24,6 29,6 36,3 39,0
combined with good service, make NS-28 8,7 11,5 13,9 19,1 22,5 32,7 39,3 48,1 51,8
our plants chosen by more and more
NS-37 10,9 14,4 17,3 23,8 28,1 40,7 48,9 59,9 64,5
customers.
NS-42 13,0 17,2 20,7 29,4 34,5 48,6 58,4 71,5 77,0
Our systems produce high quality NS-49 15,1 20,1 24,3 33,0 38,9 56,4 67,8 83,1 89,4
nitrogen, with impurities being as low NS-56 17,2 22,9 27,7 37,6 44,3 64,2 77,1 94,5 101,7
as 10 ppm or up to 3%, depending on
customer needs.

GENERATOR SETUP
Outlet Receiver
Compressor Generator Buffer Vessel (optional)

Compressed air
ISO 8573-2010 Filters Filters
Class (%): 2-4-4 PE SMF/AK
Class (ppm): 2-2-2 Dryer

Ultrafilter Skandinavien ApS - +45 82 30 30 20 - info@ultra-filter.com 70


OXYGEN GENERATOR
OS

Technical Data

Pressure: 10 or 12 bar
Dewpoint: ≤ -40

Features & Benefits


High flow, low air to oxygen ratio.
Modular design.
Expandable on location.
Siemens PLC S7
Oxygen Analyser (optional)
Flow Control (optional)

The air around us is composed of nitrogen Oxygen Production Flow (Nm³/h)


(78%) and Oxygen (21%) and small amounts Model
of different gasses and elements. Therefore, it 90 vol. % 93 vol. % 95 vol. %
may be economically advantageous to recover OS-8 2,6 2,6 2,5
oxygen itself for production or treatment. OS-16 5,3 5,2 5,1
OS-24 8,0 7,8 7,6
Ultrafilters Oxygen generator is a modular OS-32 10,6 10,3 10,1
system that could easily be increased as
OS-40 13,1 12,8 12,5
necessary, in case of an expanded production.
The purity of oxygen is continuously monitored OS-48 15,6 15,1 14,9
by a highly precise analyzer, and you can
choose between a purity of 90% or 95%.
When oxygen generator is certified as Class IIB
medical devices directive 93/42/CE, it is also
suitable for use in the health sector.

GENERATOR SETUP
Outlet Receiver
Compressor Generator Buffer Vessel (optional)

Compressed air
ISO 8573-2010 Filters Filters
Class (%): 2-4-4 PE SMF/AK
Class (ppm): 2-2-2 Dryer

Ultrafilter Skandinavien ApS - +45 82 30 30 20 - info@ultra-filter.com 71


TWIN TOWER NITROGEN GENERATOR
NS-100 / NS-200 / NS-300

Technical Data

Pressure: 7,5 or 10 bar


Dewpoint: ≤ -40
Power: 110-230 V / 50-60Hz

Features & Benefits


Feed air connection: 2” BSP
Noise Level: Below 75 dB(a)
Power consumption: 0,3 kW
Feed Air ISO 8573 Class: 1.4.1
Flow control and oxygen analyser (option)

The NS generators extract the available nitrogen in the ambient air from the other gases by applying the
Pressure Swing Adsorption (PSA) technology. During the PSA process compressed, cleaned ambient air
is led to a molecular sieve bed, which allows the nitrogen to pass through as a product gas, but adsorbs
other gases. The sieve releases the adsorbed gases to the atmosphere, when the outlet valve is closed
and the bed pressure returns to ambient pressure. Afterwards, the bed will be purged with nitrogen before
fresh compressed air will enter for a new production cycle. In order to guarantee a constant product flow, the
NS nitrogen generators use modules of two molecular sieve beds, which alternatively switch between the
adsorption and the regeneration phase. Under normal operating conditions and with correct maintenance the
molecular sieve beds will have an almost indefinite lifetime.
Nitrogen Production Flow (Nm³/h)
Oxygen
Model Content 5% 3% 2% 1% 0,5% 0,1% 100 ppm 50 ppm 10 ppm
Feed Air
Pressure 7,5 10 7,5 10 7,5 10 7,5 10 7,5 10 7,5 10 7,5 10 7,5 10 7,5 10
Nitrogen
244 309 181 208 144 162 123 145 112 145 88 99 59 60 53 50 39 43
Flow
Nitrogen
NS-100 Pressure
5,0 7,3 5,5 7,6 5,8 7,8 6,0 8,0 6,0 8,0 6,3 8,3 6,3 8,3 6,3 8,3 6,3 8,3

Feed air
452 567 373 445 323 388 292 350 303 357 272 315 230 282 226 263 209 241
consumption
Nitrogen
462 587 344 394 273 307 233 275 212 275 166 188 112 113 101 95 75 81
Flow
Nitrogen
NS-200 Pressure
5,0 7,3 5,5 7,6 5,8 7,8 6,0 8,0 6,0 8,0 6,3 8,3 6,3 8,3 6,3 8,3 6,3 8,6

Feed air
865 1082 715 851 620 743 561 672 581 684 522 604 442 542 436 505 403 464
consumption
Nitrogen
679 863 505 579 401 451 343 404 312 405 244 277 164 166 148 140 110 119
Flow
Nitrogen
NS-300 Pressure
5,0 7,3 5,5 7,6 5,8 7,8 6,0 8,0 6,0 8,0 6,3 8,3 6,3 8,3 6,3 8,3 6,3 8,3

Feed air
1275 1593 1054 1253 914 1095 827 990 857 1009 770 891 653 800 643 746 596 685
consumption

Ultrafilter Skandinavien ApS - +45 82 30 30 20 - info@ultra-filter.com 72


TWIN TOWER OXYGEN GENERATOR
OS-80 / OS-100

Technical Data

Pressure: 7,5 bar


Dewpoint ≤ -40
Power: 110-230 V / 50-60Hz

Features & Benefits


Feed air connection: 2” BSP
Noise Level: Below 75 dB(a)
Power consumption: 0,3 kW
Feed Air ISO 8573 Class: 1.4.1
Flow control and oxygen analyser (option)

The OS generators extract the available oxygen in the ambient air


from the other gases by applying the Pressure Swing Adsorption
(PSA) technology. During the PSA process compressed, cleaned
ambient air is led to a molecular sieve bed, which allows the
oxygen to pass through as a product gas, but adsorbs other
gases. The sieve releases the adsorbed gases to the atmosphere,
when the outlet valve is closed and the bed pressure returns to
ambient pressure. Afterwards, the bed will be purged with oxygen
before fresh compressed air will enter for a new production
cycle. In order to guarantee a constant product flow, the OS
oxygen generators use modules of two molecular sieve beds,
which alternatively switch between the adsorption and the
regeneration phase. Under normal operating conditions and
with correct maintenance the molecular sieve beds will have an
almost indefinite lifetime.

Nitrogen Production Flow (Nm³/h)


Oxygen
Model Content 95% 93% 90%
Feed Air
Pressure 7,5 7,5 7,5
Oxygen
Flow 36 38 41
Oxygen
OS-80 Pressure 6 6 6
Feed air
consumption 87 87 87
Oxygen
Flow 50 52 57
Oxygen
OS-100 Pressure 6 6 6
Feed air
consumption 610 615 620

Ultrafilter Skandinavien ApS - +45 82 30 30 20 - info@ultra-filter.com 73