You are on page 1of 1

SPECIAL DESIGN II

Three-Storey Residential Building


Aesan Clyde P. Gaitan
BSEE 4-3

Abstract—A simple three-storey residential building using with II. R ESULT AND D ISCUSSION
complete lighting using DiaLux Evo.
The lighting design was evaluated using DIALux evo,
Index Terms—AutoCAD, Dialux, Lumiere
focusing on three key parameters: target lux, target minimum
lux, and energy consumption.
I. I NTRODUCTION 1. Target Lux: The design achieved the desired target lux
level. This was accomplished by carefully selecting and posi-
A. Background tioning the light fixtures to ensure optimal light distribution.
2. Target Minimum Lux: The design also met the target
AutoCAD and Dialux evo are two powerful software tools minimum lux requirement. This ensures that even in the
that can be used to design and simulate a 3 storey residential worst-case scenario, the lighting levels will not fall below the
building with optimal lighting. AutoCAD is a computer-aided acceptable limit.
design (CAD) program that allows users to create 2D and 3D Energy Consumption: The energy consumption of the light-
drawings of buildings, structures, and objects. Dialux evo is ing installation was within the specified limits. The DIALux
a lighting design software that enables users to calculate and evo software provides an energy consumption tool that gives
visualize the lighting effects of different luminaires, daylight, an overview of the current energy consumption of the in-
and color schemes. By combining these two software, one can stallation and how much energy can be saved. The energy
create a realistic and efficient 3 storey residential building that tachometer can take into account the whole project or only
meets the architectural and lighting requirements. the current scene visible in the CAD window.
The process of creating a 3 storey residential building using The results indicate that the lighting design meets all the
AutoCAD and Dialux evo can be divided into the following specified requirements. Achieving the target and minimum lux
steps: levels ensures that the space is well-lit, providing a comfort-
1. Create the floor plan of the building in AutoCAD, using able and productive environment. The energy consumption is
the appropriate dimensions, layers, and blocks. The floor plan within the acceptable range, demonstrating the efficiency of
should include the walls, doors, windows, stairs, furniture, and the design. This is crucial in today’s context, where energy
other elements of the building. efficiency and sustainability are of paramount importance.
2. Export the floor plan as a DWG file and import it into III. C ONCLUSION
Dialux evo. Adjust the scale and orientation of the imported
The lighting design, as evaluated using DIALux evo, suc-
file to match the Dialux evo workspace.
cessfully meets the specified requirements in terms of tar-
3. Define the rooms and spaces of the building in Dialux
get lux, target minimum lux, and energy consumption. This
evo, using the imported floor plan as a reference. Assign the
achievement underscores the effectiveness of the design in
relevant usage profiles, materials, and colors to each room and
providing optimal lighting conditions while maintaining en-
space.
ergy efficiency.
4. Add the luminaires and daylight sources to the building in However, it’s important to remember that these results are
Dialux evo, using the luminaire database and the geolocation contingent on the current design and settings. Changes in
feature. Choose the appropriate luminaire types, positions, layout, fixture selection, or usage patterns could alter these out-
orientations, and controls for each room and space. comes. Therefore, periodic review and updating of the lighting
5. Calculate and visualize the lighting results of the building design are recommended to ensure continued compliance with
in Dialux evo, using the output options and the 3D view. Eval- requirements.
uate the lighting quality, energy consumption, and compliance This successful implementation demonstrates the potential
with the lighting standards and regulations of the building. of careful and thoughtful lighting design in creating comfort-
6. Export the lighting results as a PDF report and a 3D able, productive, and sustainable environments. It serves as a
model from Dialux evo. Import the 3D model into AutoCAD testament to the power of technology in facilitating efficient
and combine it with the original floor plan to create a complete and effective lighting solutions.
3D representation of the building.