NOTE: The following is the schematic which shows the baler electric's in standard form (less the optional cutter).
A 25 amps circuit breaker (1) protects the entire system. 12 volts from the tractor battery cable (13) go to a 20
amps (2) in the operator panel (3) through the main tractor harness (4) .
When the system is turned on, power is sent from a relay (5) to the baler through the baler harness connector (6) .
The baler harness (7) is connected to the controller (8) , the net actuator (9) , the twine actuator (10) plus the
tailgate switches (11) , twine actuator sensor (12) , bale density sensors (14 and 15) , net counter roll sensor (16)
and net actuator sensor (17) .