You are on page 1of 2

Motor Datasheet

Product information in accordance with commission regulation (EU) no. 2019/1781,


annex I - item no. 2

Frame size : JPU-DF315MA


load 50 Hz 60 Hz
Housing material: CAST IRON
Rated efficiency at
1 rated load
100% 95.6 96.2 Mounting: FOOT, HORIZONTAL (IM1001) (B3)

75% 95.8 96.4 Degree of protection: IP55

50% 95.3 95.9 Method of cooling: IC411

2 Efficiency level: IE3 IE3 Thermal class: 155(F)

Manufacturer name / trade mark / Commercial registration no. / address: Motor weight: 920 kg (approx.)

3 Brook Crompton UK Ltd registration number 4305426

Registered Office: St Thomas’ Road, Huddersfield, HD1 3LJ Terminal box position: Top

Motor type: AC INDUCTION Cable entry: 2 X CM63


4
Motor part number: 315J952402 Cable gland: YES

5 Number of poles: 4 Terminal board pin size: M12

6 Rated power output (kW): 132.0 132.0

7 Rated input frequency (Hz): 50 60 DE bearing: 6319 C3

8 Rated voltage (V): 400 / 690 460 NDE bearing: 6319 C3


1
9 Rated speed (min- ): 1490 1790 Regreasing facility: YES

10 Phase: 3 Grease: LITHIUM

Altitudes above sea-level: 1000m

Ambient air temperatures: -20°C +40°C Balance grade: 2.8 mm/sec


2
11 Water coolant temperature: - Rotor inertia: 3.606 kgm
Maximum operating temp: - Rotation direction: CLOCKWISE AT DRIVE END

Potentially explosives atmosphere: NO (SAFE AREA)

Exempt from regulation: NO Paint system: C3

12 Reason of exemption: - Colour: RAL5021 (WATER BLUE)

(90/100) NOT APPLICABLE Sound pressure 50Hz: 72 dB(A)

Power losses: (90/50) NOT APPLICABLE Sound pressure 60Hz: 74 dB(A)


Power losses in % (50/100) NOT APPLICABLE
of the rated output
13 at the following (50/50) NOT APPLICABLE Winding protection: 150°C PTC (THERMISTORS)
operation points
(speed vs. torque (50/25) NOT APPLICABLE Heaters: 110 / 220 V 120 W
values): (25/100) NOT APPLICABLE

(25/25) NOT APPLICABLE Hazardous area marking: -

Certificate number: -

tE time: -
50 Hz 60 Hz

100% 0.86 0.86 Typical Torque and Current Vs Speed curve


Power factor: 75% 0.83 0.83

50% 0.75 0.75


Phase connection: DELTA / STAR DELTA
Rated current (A): 232 / 134 200.0
Duty: S1 S1
Rated torque (Nm): 846 704.2
Starting current (Ia/In): 8 9.1
Starting torque (Ma/Mn): 2.6 2.8
Breakdown torque (Mk/Mn): 3.3 3.6

Remarks:

All data subject to tolerance


author: BCUK date: 08/06/2022 version: 5.1 / 1
This document is exclusive property of Brook Crompton UK
Reprinting is not allowed without written authorization of Brook Crompton UK
Subject to change without notice