You are on page 1of 1

ARCHITECH CAD ACADEMY

ENGINEERING DRAUGHTSMANSHIP
WITH AUTOCAD - AC 306
PRACTICAL - 06
ASBESTOS ROOFING
FOR WATER TANK 2"X4" RAFTERS

ASBESTOS ROOFING
2"X2" BATTENS

1529
2242

2242
2"X4" RAFTERS
WATER
TANK

2257
+7.150

3161
WATER

1632
TANK
2025 2400 5100

1075
LEVEL

600
300
900

3600
FL1

3525
BATH 3"X4" WALL PLATE
UPPER LIVING

18°
9392

2083
2100
9" BRICK WALL

750 691
1"X9" VALANCE

1550
BOARD WITH

900
5" THK. SECONDRY
CONCRETE FILL +3.500 +3.550 GURTER BRACKET
FG2

9"X1' RCC. BEAM

725
2250 2325 1800 2325 600

646
750 125 mm Thk.
1200 RCC. SLAB

3300
FG1
3125

2400
2100 TV LOBBY LIVING
W1
1200

174
3" THK. LEAN CONCRETE
+0.250
+0.000 +0.000

175 mm THK. COMPACTED


SEE FDN. DETAILS EARTH FILL
(450 mm WIDE RRF.) SEE FDN. DETAILS
(450 mm WIDE RRF.)
SECTION X - X
SCALE - 1 : 100

FOLLOW GIVEN BELOW INSTRUCTIONS


01 . USE PRACTICAL - 01 OBJECTS PROPERTIES TO COMPLETE GIVEN SECTION.
02 . DO NOT MENTION BLUE COLOUR DISCRIPTIONS IN THE DRAWING.
03 . SELECT & USE SUITABLE HATCH PATERNS FOR RANDOM RUBBLE FOUNDATION (RRF),
COMPECTED EARTH FILL, RCC. CONCRETE & SCREED CONCRETE.
04 . ROOF ANGLES SHAL BE 18°.
05 . ALL WALLS ARE SHALL BE 6 " CEMENT BLOCK WALLS UNLESS OTHERWISE SPECIFIED.
06 . ALL BEAMS SHAL BE 225 mm X 300 mm.
PREPARED BY - PATHUM PEIRIS