You are on page 1of 11

KEY PLAN

A
M-1A-0511

NOTE & LEGEND


ø100 mm PD DISCLAIMER:
BOP ± -968 DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

ø150 mm PD
ø65 mm PD
BOP ± -1543

B
M-1A-0511

DETAIL - SUMP PIT 6 1


SCALE 1 : 20 M-1A-1107

EL. -0.250 ø65 mm PD


BOP ± -645 - = REVISION MARK = REVISION CLOUD
SLOPE 0.50%
150

150
ø100 mm PD
BOP ± -968

ø100 mm PD
BOP ± -968 FROM PRETREATMENT LAUNDRY
1200

1200
ø65 mm PD ø65 mm PD
ø150 mm PD A ISSUED FOR TENDER
ø150 mm PD BOP ± -1543
BOP ± -1543

FROM RISER PRODUCTION


WATER LEVEL WATER LEVEL
3650

3650

A 08-09-2023 FJ KIS FM EA BN IFT


CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. MgrProj. Mgr
CLIENT :
2000

2000

PT. Erlangga Edi Laboratories


CONSULTANT : PT TeamworX Indonesia
Beltway Office Park

TeamworX
Building C, Ground Floor
Jl. TB. Simatupang No. 41, Cilandak
Jakarta Selatan 12550 - INDONESIA
Phone : +62 21 780 0940
Fax : +62 21 789 2151
Website : www.teamworx.co.id
150 150

150 150

PROJECT TITLE :

EPCM Services for New Facility


150 650 200 2150 150
Expansion Project at Salatiga
150 3000 150
3300
3300 DRAWING TITLE :
SCALE
PLOT
DETAILS - MECHANICAL STANDARDS #10 1 : 20

SECTION A SECTION B
FOR TENDER ONLY
SCALE 1 : 20 M-1A-0511
M-1A-0511
SCALE 1 : 20
DRAWING NUMBER :
4217-CSD-M-1A-0511-RA
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN
B
M-1A-0512

ø65 mm VT ø50 mm PD ø125 mm PD


BOP ± -1441 BOP ± -1423
FROM 1ST FL. FROM RISER
NOTE & LEGEND
DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

A
M-1A-0512

ø100 mm PD
BOP ± -415

TO SUMP PIT - 5

DETAIL - SUMP PIT 7 1


SCALE 1 : 20 M-1A-1107
1000

1000
ø65 mm VT
ø65 mm VT
1st Floor - = REVISION MARK = REVISION CLOUD
EL. -0.050
EL.+0
500
650

BU CV
150

1450
A ISSUED FOR TENDER
ø65 mm PD ø65 mm PD
ø125 mm PD
BOP ± -1423 ø50 mm PD
800

FROM RISER BOP ± -1441


SLOPE 2.00%
ø50 mm PD
FROM 1ST FL.
BOP ± -1441 WATER LEVEL WATER LEVEL

A 08-09-2023 FJ KIS FM EA BN IFT

3750
CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. MgrProj. Mgr
CLIENT :
3100
2000

2000
PT. Erlangga Edi Laboratories
CONSULTANT : PT TeamworX Indonesia
Beltway Office Park

TeamworX
Building C, Ground Floor
Jl. TB. Simatupang No. 41, Cilandak
Jakarta Selatan 12550 - INDONESIA
Phone : +62 21 780 0940
Fax : +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


150 150

150 150
Expansion Project at Salatiga
150 500 150 650 200 2850 150 150 2400 150 DRAWING TITLE :
SCALE
650 4000 2700
PLOT
DETAILS - MECHANICAL STANDARDS #11 1 : 20

SECTION A SECTION
SCALE 1 : 20 M-1A-0512 SCALE 1 : 20
B
M-1A-0512 FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0512-RA
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN

NOTE & LEGEND


DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

- = REVISION MARK = REVISION CLOUD

B ISSUED FOR TENDER


A FIRST ISSUED

B 08-09-2023 FJ KIS FM EA BN IFT


A 14-07-2023 BP KIS FM EA BN IFA
CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. Mgr Proj. Mgr
CLIENT :

PT. Erlangga Edi Laboratories


CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor

TeamworX Jl. TB. Simatupang No. 41, Cilandak


Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


Expansion Project at Salatiga
DRAWING TITLE :
0. GENERAL - PHASE 1A SCALE
PLOT
SCHEDULES - MECHANICAL EQUIPMENT #1 1 : 95

SCHEDULES - MECHANICAL EQUIPMENT #1 (PHASE 1A)


SCALE : NTS
FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0601-RB
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN

NOTE & LEGEND


DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

- = REVISION MARK = REVISION CLOUD

B ISSUED FOR TENDER


A FIRST ISSUED

B 08-09-2023 FJ KIS FM EA BN IFT


A 14-07-2023 BP KIS FM EA BN IFA
CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. Mgr Proj. Mgr
CLIENT :

PT. Erlangga Edi Laboratories


CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor

TeamworX Jl. TB. Simatupang No. 41, Cilandak


Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


Expansion Project at Salatiga
DRAWING TITLE :
0. GENERAL - PHASE 1A SCALE
PLOT
SCHEDULES - MECHANICAL EQUIPMENT #2 1 : 95
SCHEDULES - MECHANICAL EQUIPMENT #2 (PHASE 1A)
SCALE : NTS

FOR TENDER ONLY DRAWING NUMBER :


4217-CSD-M-1A-0602-RB
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN

NOTE & LEGEND


DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

- = REVISION MARK = REVISION CLOUD

B ISSUED FOR TENDER


A FIRST ISSUED

B 08-09-2023 FJ KIS FM EA BN IFT


A 14-07-2023 BP KIS FM EA BN IFA
CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. Mgr Proj. Mgr
CLIENT :

PT. Erlangga Edi Laboratories


CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor

TeamworX Jl. TB. Simatupang No. 41, Cilandak


Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


Expansion Project at Salatiga
DRAWING TITLE :
0. GENERAL - PHASE 1A SCALE
PLOT
SCHEDULES - MECHANICAL EQUIPMENT #3 1 : 95

SCHEDULES - MECHANICAL EQUIPMENT #3 (PHASE 1A) FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0603-RB
SCALE : NTS
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN

NOTE & LEGEND


DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

- = REVISION MARK = REVISION CLOUD

B ISSUED FOR TENDER


A FIRST ISSUED

B 08-09-2023 FJ KIS FM EA BN IFT


A 14-07-2023 BP KIS FM EA BN IFA
CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. Mgr Proj. Mgr
CLIENT :

PT. Erlangga Edi Laboratories


CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor

TeamworX Jl. TB. Simatupang No. 41, Cilandak


Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


Expansion Project at Salatiga
DRAWING TITLE :
0. GENERAL - PHASE 1A SCALE
PLOT
SCHEDULES - MECHANICAL EQUIPMENT #4 1 : 95

SCHEDULES - MECHANICAL EQUIPMENT #4 (PHASE 1A) FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0604-RB
SCALE : NTS
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN

NOTE & LEGEND


DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

LEGEND :

RW
: RAW WATER PIPE

BY BY
VENDOR CONTRACTOR

PI

BV
FROM DEEP WELL Ø100-RW Ø100-RW
PUMP 01
CV

Ø100-RW RAW WATER


M-1A-0730
TO WTP / PUMP AREA

PI

BV
FROM DEEP WELL Ø40-RW Ø40-RW
PUMP 02
CV - = REVISION MARK = REVISION CLOUD

PI
B ISSUED FOR TENDER
BV

A FIRST
FIRST ISSUED
FROM DEEP WELL Ø40-RW Ø40-RW A ISSUED

PUMP 03
CV

B 08-09-2023 FJ KIS FM EA BN IFT


A 14-07-2023 BP
BP KIS FM
FM EA BN IFA
IFA
CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. Mgr Proj. Mgr
CLIENT :

PT. Erlangga Edi Laboratories


CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor

TeamworX Jl. TB. Simatupang No. 41, Cilandak


Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


Expansion Project at Salatiga
DRAWING TITLE :
SCALE
0. GENERAL - PHASE 1A PLOT
SCHEMATICS - RAW WATER PIPE INSTALLATION SYSTEM (PHASE 1A) SCHEMATICS - RAW WATER PIPE
SCALE : NTS
INSTALLATION SYSTEM
FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0701-RB
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN

M-1A-0703, SHEET 2

M-1A-0703, SHEET 2
TO 3RD FLOOR

TO 3RD FLOOR
EL +15.600
3RD FLOOR NOTE & LEGEND
DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
Ø80 - CDW Ø80 - CDW Ø80 - CDW Ø80 - CDW Ø80 - CDW Ø80 - CDW SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.

Ø20

Ø20
Ø32

Ø40 - CDW Ø40 - CDW APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE

Ø25
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

Ø20
Ø100 - CDW

Ø15 - CDW ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.


3-2M11 LAUNDRY 3-2M12 M. CHANGE ROOM (CNC) 1-2M15 AHU - 2M ROOM 1-2077 AHU PLANT AREA 3-2M99 COMP. AIR PLANT LEGEND :
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
3-2M10 PRAYER R. MALE 3-2M09 TOILET MALE CDW

Ø40 - CDW
LV 9 FC 1 FC 1 FC 1 : POTABLE WATER PIPE
LAUNDRY EQUIP. 3
FIXTURES QUANTITY FIXTURES QUANTITY
EW 1 EWS 1
FC 3 WC 3 1-2M03 AHU - COATER
HDW GENERATOR 1
UR 2 FIXTURES QUANTITY
EL +11.400
LV 3 FC 1 2ND MEZ. FL.

Ø25 - CDW Ø15 - CDW


Ø100 - CDW

Ø25

Ø20
3-2058 F. CHANGE ROOM (CNC) 1-2031 VISITOR CHANGE ROOM 5-2-02 AHU-AUDITORIUM R.
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
LV 9 LV 3 FC 1

Ø50 - CDW Ø50 - CDW Ø32 - CDW Ø25 - CDW Ø20 - CDW Ø20 - CDW Ø40 - CDW

Ø32 - CDW Ø32 - CDW

Ø20

Ø20
Ø20
Ø100 - CDW

3-2060 LAUNDRY 1-2067 JC 1-2006 F. CHANGE ROOM 1-2005 M. CHANGE ROOM 4-2-01 POWDER
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
3-2061 PRAYER ROOM (FEMALE) 3-2062 TOILET FEMALE
LAUNDRY EQUIP. 3 FC 1 LV 2 LV 3 WC 1
FIXTURES QUANTITY FIXTURES QUANTITY
EWS 1 UR 1
FC 3 WC 5 EL +7.200
LV 1
LV 3 2ND FLOOR

Ø40 - CDW
- = REVISION MARK = REVISION CLOUD

Ø50 - CDW Ø50 - CDW Ø50 - CDW Ø40 - CDW Ø50 - CDW Ø50 - CDW Ø50 - CDW Ø32 - CDW
Ø32 - CDW
Ø32

Ø40

Ø25

Ø50

Ø20

Ø32

Ø15
Ø50 - CDW
Ø100 - CDW

1-1045 WASH ROOM 1-1050 TEMPORARY TRUCKERS 1-1060B FEMALE TOILET 1-1060A MALE TOILET 5-1-12 MALE TOILET 5-1-11 DISABLE TOILET 5-1-13 FEMALE TOILET 5-1-14 JANITOR
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
3-1066 BOILER ROOM B ISSUED FOR TENDER
SINK 1 WC 1 WC 1 WC 1 WC 3 WC 1 WC 5 FC 1
FIXTURES QUANTITY A FIRST ISSUED
UR 1 LV 2 LV 1 UR 2 LV 1 LV 3
EWS 1
LV 1 UR 2 LV 3
BLOW. TANK 1
Ø50 - CDW

Ø50 - CDW Ø50 - CDW Ø50 - CDW Ø20 - CDW Ø20 - CDW Ø20 - CDW Ø15 - CDW Ø20- CDW Ø32 - CDW

Ø15

Ø20
Ø32

Ø20

Ø20
Ø125 - CDW

B 08-09-2023 FJ KIS FM EA BN IFT


A 14-07-2023 BP KIS FM EA BN IFA
CHECKED BY: APPROVED BY :
3-1065 CHILLER ROOM 5-1-04 KITCHEN 5-1-06 TOILET FITTING R. - POND 1-1020 WASH ROOM 1-1031 JANITOR 6-1-02 TOILET GUARD H. 1 - POND REV. DATE CLIENT ISSUANCE
Drafter Sr. Eng. Eng. Mgr Proj. Mgr
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY CLIENT :
EWS 1 FC 1 WC 2 FC 1 FC 1 FC 1 WC 1 FC 1
FC 1 B LV 1 FC 1
EL +0.0
1ST FLOOR
PT. Erlangga Edi Laboratories
CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor
BD 17 - CANTEEN BD 8 - GUARD HOUSE 3
BD 16 - WASTE STORAGE B3
Ø50 - CDW Ø50 - CDW Ø50 - CDW Ø25 - CDW Ø25 - CDW Ø20 - CDW Ø20 - CDW TeamworX Jl. TB. Simatupang No. 41, Cilandak
Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

16-1-01 WASTE STORAGE 17-1-01 CANTEEN 17-1-09 FEMALE TOILET 17-1-07 MALE TOILET 17-1-12 JANITOR 17-1-04 FOOD PREPARATION 17-1-03 LOBBY & HAND BASIN 8-1-02 TOILET EPCM Services for New Facility
Ø32 - CDW

FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
FC 4 WC WC 1 FC 1 FC 2 FC 8
Expansion Project at Salatiga
EWS/SS 1 1 WC 1
EL +0.0 LV 2 LV 2 EL +0.0 LV 1 EL +0.0 DRAWING TITLE :
GND FL UR 2 GND FL FC 1 GND FL SCALE
0. GENERAL PLOT
POTABLE WATER
M-1A-0730 Ø125 - CDW Ø50-CDW Ø20 - CDW
SCHEMATIC - POTABLE WATER PIPE
FROM WTP / PUMP AREA SYSTEM , SHEET 1
FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0702-RB
SCHEMATICS - POTABLE WATER PIPE SYSTEM , SHEET 1 THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO
SCALE : NTS at A1
COPYRIGHT
KEY PLAN

EL +29.000
ROOF

Ø50 - CDW Ø50 - CDW Ø20 - CDW Ø20 - CDW

AAV

Ø50
Ø25

Ø15

Ø15
NOTE & LEGEND
1-4M14 FEMALE TOILET 1-4M13 MALE TOILET 1-4M12 PANTRY 3-4M01 AHU - 4 ROOM 1-4M04 TOILET
DISCLAIMER:
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY DRAWING SHOWS IS NOT A SHOPDRAWING:
WC 3 WC 2 SINK 1 FC 1 WC 1 INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
LV 3 LV 2 LV 1 EL +28.200 PROCESS.
UR 2 4TH MEZZ APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

Ø20 - CDW Ø32 - CDW LEGEND :

Ø15

Ø15

Ø15

Ø15
Ø15

Ø15
CDW
: POTABLE WATER PIPE

1-4503 BATH ROOM 1-4302 SENSORY ROOM 1-4214 WASH & DECON 1-4305 GLASSWARE STORAGE 1-4306 PRIMARY PACKAGING 1-4309 GRANULATION 1 ROOM 1-4313 AYAKAN

Ø32 - CDW
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
WC 1 LV 1 SINK 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1
LV 1
SHOWER 1
Ø50 - CDW Ø50 - CDW
Ø25 - CDW Ø15 - CDW Ø15 - CDW Ø32 - CDW

Ø15
Ø15- CDW

Ø20

Ø15

Ø15

Ø15
Ø15
1-4007 TOILET MALE 1-4506 PANTRY
FIXTURES QUANTITY FIXTURES QUANTITY 1-4415 GLASSWARE & WASH R. 1-4414 FUME HOOD 1-4413 ORGANIC ROOM 1-4410 DISSOLUTION ROOM 1-4316 DRYING FBD 1-4315 GRANULATION 2 R. 1-4314 FINAL MIXING R.
1-4102 MALE CHANGE ROOM WC 2 SINK 1

Ø32 - CDW
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
FIXTURES QUANTITY UR 3 SINK 2 SINK 1 SINK 1 SINK 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1
FC 3 LV 3
Ø15- CDW Ø25 - CDW Ø15 - CDW Ø15 - CDW Ø32 - CDW Ø32 - CDW
Ø25

Ø15

Ø15

Ø15

Ø15
Ø25 - CDW
Ø50 - CDW

AAV
Ø25 - CDW

1-4101 FEMALE CHANGE ROOM 1-4008 TOILET FEMALE 1-4332 WASH AREA 1-4317 COATING 2 ROOM 1-4318 COATING 1 ROOM 1-4319 COMPACTOR ROOM 1-4320 PRINTING ROOM 1-4407 PREPARATION ROOM
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
Ø40 - CDW
FC 3 WC 3 SINK 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1 SINK 1
LV 3 EWS 1
Ø50 - CDW Ø50 - CDW Ø32 - CDW Ø32 - CDW Ø32 - CDW
Ø15

1-4003 POWDER

Ø15

Ø15

Ø15

Ø15
Ø32

Ø15

FIXTURES QUANTITY - = REVISION MARK = REVISION CLOUD

Ø40 - CDW
WC 1
1-4118 FLAMMABLE STORAGE 1-4204 JANITOR 1-4401 LOCKER 1-4326 FILLING SEMISOLID R. 1-4325 MIXING SEMISOLID R. 1-4324 COLLOID MILL R. 1-4323 FILLING LIQ. ROOM 1-4322 MIXING LIQ. ROOM LV 1
Ø50- CDW

FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY UR 1
EWS/SS 1 FC 1 EWS/SS 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1 MANUAL POU 1
EL +24.000
4TH FLOOR

Ø100 - CDW Ø25- CDW Ø15- CDW B ISSUED FOR TENDER


A FIRST ISSUED
Ø15

Ø40 - CDW
Ø100 - CDW

3-3M02 COOLING TOWER 3-3M01 AHU ROOM -3


FIXTURES QUANTITY FIXTURES QUANTITY
FC 1 FC 1
EL +19.800
3RD MEZZ

B 08-09-2023 FJ KIS FM EA BN IFT


Ø100 - CDW Ø100 - CDW Ø80 - CDW Ø80 - CDW Ø40 - CDW A 14-07-2023 BP KIS FM EA BN IFA
CHECKED BY: APPROVED BY :
Ø15

Ø15

Ø15

Ø15
Ø100 - CDW

REV. DATE CLIENT ISSUANCE


Drafter Sr. Eng. Eng. Mgr Proj. Mgr
CLIENT :

3-3044 AHU PLANT ROOM 1-3037 JANITOR 1-3040 WASH AREA 1-3067 PANTRY 1-3068 JANITOR 1-3047 CLEAN UTILITY AREA 4-3-01 POWDER

Ø50 - CDW
FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY FIXTURES QUANTITY
FC 1 FC 1 EQUIPMENT 2 KITCHEN SINK 1 FC 1 SOFT WATER GEN. 2 WC 1
SINK 1 FC 1 UR 1 PT. Erlangga Edi Laboratories
CONSULTANT : PT TeamworX Indonesia
EWS 1 EWS 1 LV 1 Beltway Office Park
Building C, Ground Floor

EL +15.600
3RD FL
TeamworX Jl. TB. Simatupang No. 41, Cilandak
Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


M-1A-0702, SHEET 1

M-1A-0702, SHEET 1
FROM 2ND MEZZ

FROM 2ND MEZZ


Expansion Project at Salatiga
DRAWING TITLE :
SCALE
0. GENERAL PLOT

SCHEMATIC - POTABLE WATER PIPE


SYSTEM, SHEET 2
SCHEMATICS - POTABLE WATER PIPE SYSTEM , SHEET 2 FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0703-RB
SCALE : NTS
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN
Note :
This design is based on our vendor's design. Any design proposed by other
vendor shall be accepted with condition the performance guaranteed should
be the same or greater than our design.

NOTE & LEGEND


DISCLAIMER:
DRAWING SHOWS IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS.
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
Ø80 - HDW ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.
HDW
BtV M-1A-0705, SHEET 2 LEGEND :
GV
HDW
: HOT POTABLE WATER PIPE
IS
: INDUSTRIAL STEAM PIPE
SC
: STEAM CONDENSATE PIPE
Ø80 - CDW CDW MW
M-1A-0702, SHEET 1 : MAKE UP WATER PIPE
GV STR BV

Ø80 - HDW HDW


GV M-1A-0705, SHEET 2

HOT POTABLE
MIG BV CONTROL
WATER TANK 3 m3
PANEL

GLV

TI TT TT PG PG
GV
SP
Ø80 - IS IS
M-1A-0713, SHEET 2
GV GV GV STR BV PRV GV INDUSTRIAL STEAM
BV

BV - = REVISION MARK = REVISION CLOUD


ST GV
TO DRAIN

TI

TO DRAIN

PHE 01 B ISSUED FOR TENDER


CAP. 17.3 M3/H A FIRST ISSUED
BtV PRESSURE 8 BAR

CV BtV

M GLV GLV
STR
B 08-09-2023 FJ KIS FM EA BN IFT
BtV STR HWP 01 A 14-07-2023 BP KIS FM EA BN IFA
CAP. 17.3 M3/H Ø25 - SC SC CHECKED BY: APPROVED BY :
REV. DATE CLIENT ISSUANCE
M-1A-0713, SHEET 2 Drafter Sr. Eng. Eng. Mgr Proj. Mgr
PRESSURE 8 BAR
STEAM CONDENSATE CLIENT :
CV CONDENSATE CV
MECHANICAL PUMP
CAP. 2 M3/H
PRESSURE 8 BAR
PT. Erlangga Edi Laboratories
CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor

TeamworX Jl. TB. Simatupang No. 41, Cilandak


Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


Expansion Project at Salatiga
DRAWING TITLE :
SCHEMATICS - HOT POTABLE WATER PIPE SYSTEM, SHEET 1 (PHASE 1A) 0. GENERAL
SCALE
PLOT
SCALE : NTS
SCHEMATICS - HOT POTABLE
WATER PIPE SYSTEM, SHEET 1
FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0704-RB
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT
KEY PLAN

NOTE & LEGEND


DISCLAIMER:
LEGENDSHOWS
DRAWING : IS NOT A SHOPDRAWING:
INFORMATION DEPICTED IS SUBJECT TO CLIENT AND A/E APPROVAL IN
SUBMITTALS
HDW ISSUED BY THE CONTRACTOR IN THE PRE-CONSTRUCTION
PROCESS. : HOT POTABLE WATER PIPE
APPROVED SUBMITTALS SHALL BE SUBJECT TO FIELD-VERIFICATION BY THE
ENGINEER PRIOR TO INSTALLATION ON-SITE.
ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
ALL LEVEL ARE IN METERS UNLESS NOTED OTHERWISE.

Ø80 - HDW

Ø80 - HDW
Ø80 - HDW

Ø20 - HDW Ø50 - HDW Ø50 - HDW

WET GRANULATION ROOM NAME WASH AREA ROOM NAME TECHNICAL AREA
ROOM NAME
(300kg/run) ROOM No. 1-3041A ROOM No. 1-3048

Ø80 - HDW
ROOM No. 1-3019 Mobile Vessel CIP Station EQUIP NAME Cleaning Unit Skid
EQUIP NAME
EQUIP NAME High Shear Mixer Granulator Pump Skid EQUIP TAG CIP-PB1-GRN-3L-001
EQUIP TAG HSMG-PB1-GRN-3L-002 EQUIP TAG PU-PB1-WSH-3L-003 FLOWRATE 6.0 m3/h
FLOWRATE 0.5 m3/h FLOWRATE 9.0 m3/h PRESSURE 2.0 barg
PRESSURE 2.0 barg PRESSURE 4.0 barg TEMPERATURE 60 °C EL +15.600
TEMPERATURE 60 °C TEMPERATURE 60 °C 3RD FLOOR

HDW
M-1A-0704, SHEET 1

HDW - = REVISION MARK = REVISION CLOUD


M-1A-0704, SHEET 1 EL +11.400
2ND MEZZ

Ø80 - HDW

Ø80 - HDW
B ISSUED FOR TENDER
A FIRST ISSUED

Ø50 - HDW Ø20 - HDW Ø20- HDW Ø20 - HDW

SUGAR COATING ROOM NAME COATING ROOM 1 ROOM NAME COATING ROOM 2 ROOM NAME COATING ROOM 3
ROOM NAME
SOLUTION PREPARATION ROOM No. 1-2052 ROOM No. 1-2050 ROOM No. 1-2048
ROOM No. 1-2075 B 08-09-2023 FJ KIS FM EA BN IFT
EQUIP NAME Tablet Coating Machine 1 EQUIP NAME Tablet Coating Machine 2 EQUIP NAME Tablet Coating Machine 3
Sugar Coating Solution A 14-07-2023 BP KIS FM EA BN IFA
EQUIP NAME EQUIP TAG CO-PB1-COT-2L-001 EQUIP TAG CO-PB1-COT-2L-002 EQUIP TAG CO-PB1-COT-2L-003
Preparation Vessel 1 CHECKED BY: APPROVED BY :
EQUIP TAG TA-PB1-COT-2L-002 FLOWRATE 0.5 m3/h FLOWRATE 0.5 m3/h FLOWRATE 0.5 m3/h REV. DATE
Drafter Sr. Eng. Eng. Mgr Proj. Mgr
CLIENT ISSUANCE

FLOWRATE 5.4 m3/h PRESSURE 2.0 barg PRESSURE 2.0 barg PRESSURE 2.0 barg CLIENT :
PRESSURE 4.0 barg TEMPERATURE 60 °C TEMPERATURE 60 °C TEMPERATURE 60 °C
TEMPERATURE 60 °C
EL +7.200
2ND FLOOR
PT. Erlangga Edi Laboratories
CONSULTANT : PT TeamworX Indonesia
Beltway Office Park
Building C, Ground Floor

TeamworX Jl. TB. Simatupang No. 41, Cilandak


Jakarta Selatan 12550 - INDONESIA
Phone
Fax
: +62 21 780 0940
: +62 21 789 2151
Website : www.teamworx.co.id

PROJECT TITLE :

EPCM Services for New Facility


Expansion Project at Salatiga
DRAWING TITLE :
SCALE
0. GENERAL PLOT

SCHEMATICS - HOT POTABLE


WATER PIPE SYSTEM, SHEET 2
SCHEMATICS - HOT POTABLE WATER PIPE SYSTEM, SHEET 2 (PHASE 1A)
SCALE : NTS FOR TENDER ONLY DRAWING NUMBER :
4217-CSD-M-1A-0705-RB
THIS DRAWING IS PROPERTY OF PT. TEAMWORX INDONESIA AND IS SUBJECT TO at A1
COPYRIGHT

You might also like