$1,924.00

This unit measures kVp, mA, and mAs. It can send data to
an android phone or tablet via bluetooth connection.

It measures from 45kVp – 125kVp or 40 -120 (Model 820L)

kV Speci cations

Documents

Standard Shipping within the United States for one (1) ECC
product.

For overnight and international shipping fees please


call ECC.

1 ADD TO CART

SKU: Model 820 Category: meter Tag: calibration/measuring


devices

Description

DESCRIPTION

X-Ray kVp meter/mAs Meter: Model 820


FEATURES

Combines two instruments

kVp and mAs in one package

Easy to use
https://eccxray.com/product/model-820/ 1/3
4/6/2021 X-ray kVp meter/mAs Meter: Model 820. X-ray calibration & measuring

No need to set for AC / DC

Self-resetting

mA is stored permitting short exposures

Measures kVp and exposure time simultaneously


HOME ABOUT ECC PR ODUCTS MANUALS/ DATA SHEETS SHOP CONTACT
kVp is noninvasive

AC and DC x-rays

High accuracy

Measures kVp, mA, mAS, exposure time

Battery operated

Two year warranty

Compact size

Durable ABS plastic case

Custom carrying case included

New! Send data to smart phone via Bluetooth

This Instrument Measures kVp, mA, mAs and Exposure Time

The 820 kVp / mAs Meter combines all the features of our Model 815 kVp Meter, and adds the mA and mAs measurement
function in one compact unit. The 820 is capable of measuring kVp, mA, mAs, and exposure time. The unit is self resetting,
and automatically detects AC or DC x-ray currents, minimizing the possibility of inaccurate readings. With each mA reading,
the unit stores and displays mA, mAs and exposure time. mA is sampled for a representative length of time and saved. This
allows shorter exposure times minimizing xray exposure and wear and tear on the x-ray head. The Model 820 contains
exactly the same kVp measurement circuit and capability as our Model 815. The mA / mAs function has been squeezed into
the unit. The Model 820 is battery operated, user-friendly, and has a two year warranty. Applications include veri cation of
peak x-ray voltage, constancy checks, calibration of x-rays, and quality assurance measurement of exposure time. The unit is
also used for half value layer determination, troubleshooting and repair of x-rays, and quality control.

The cable supplied with the unit serves as a switch. When the cable is plugged into the unit, it is automatically con gured for
mA readings. When the cable is unplugged the Model 820 functions as a kVp meter.

The kVp Meter has CE Compliance.

All units come with a Certi cate of Calibration. Yearly calibration is suggested.

The introduction of the Model 820 allows service personnel to carry one instrument rather than an mAs Meter and a kVp
Meter.

New Improved Instrument

New Design Improvements to the Model 820 include the following:

Remote Readout

820 kVp meter using remote readout

https://eccxray.com/product/model-820/ 2/3
4/6/2021 X-ray kVp meter/mAs Meter: Model 820. X-ray calibration & measuring

The all new model 820 is now capable of transmitting data to an Android device via a bluetooth connection. Go to the
Google Play store on your smartphone and search for ECC 820/815: Remote Monitor. Use this app to connect to your Model
820 and the readings will be sent directly to your phone’s display.

New X-ray Detectors

HOME
The Model ABOUT
820 has been redesigned ECC
to usePR ODUCTS
a new MANUALS/
x-ray detector. DATA SHEETS
The new detectors are more stable,SHOP CONTACT
more repeatable and
have greater range than the previous versions. The measurement range is now 40 to 125 kV.

New Software Operating System

Improvements have been made in the internal microcomputer program that facilitates faster measurements. There is no
minimum exposure time requirement for mA / mAs measurement. The mA and mAs measurements are more accurate
because we are measuring the current for the entire x-ray exposure.The minimum exposure time needed for kVp
measurements has been reduced to 40 ms (0.04 second). This allows more exibility when the x-ray is set up based on mAs
rather than exposure time. This new feature virtually eliminates sources of error when certain techniques result in short
exposure times. The shorter exposure times also give you less wear and tear on x-ray equipment as well as less x-ray
exposure to test personnel.

This is a software only change, therefore we will be able to retro t any instruments that are sent to us for calibration.

RELATED PRODUCTS

MODEL 8700 X-RAY UNIVERSAL X-RAY DOSE/ KVP/ MAS KVP X-RAY METER:
PULSE COUNTER & INSTRUMENT ( UXI) COMBINATION KIT 82 0 MODEL 81 5
EXPOSURE TIME METER ALL-PURPOSE METER OR 82 0L, PLUS 890 $1,435.00
$477.00 $3,605.00 $2,383.00

ADD TO CART
ADD TO CART ADD TO CART ADD TO CART

Copyright © 2020 Electronic Control Concepts | Designed by Main Street Graphics

https://eccxray.com/product/model-820/ 3/3

You might also like