SR.
DESCRIPTION UNITS SPECIFIED DATA Confirmed / Not
NO. Remarks
Confirmed
1.0 GENERAL
1.1 Offer Number VTA
1.2 Name of sub-supplier if any VTA
1.3 Quantity required One (1)
1.4 Comply with vessel D/S (KU-TWK-20-ME-DTS-0006-Rev A) VTC
2.0 Proces/ Design Data
2.1 Fluid Diesel Confirmed
2.2 Design Code UL-142 Latest Edition Confirmed
2.3 Sour Service N/A
2.4 Lethal Service N/A
2.5 Density kg/m3 850-880 Confirmed
2.6 Operating Pressure ATM Confirmed
Full of Water + 5 mbarg / -2.5
2.7 Design Pressure (int./ext.) confirmed
mbarg
2.8 Operating Temperature °C -10 / 55 confirmed
2.9 Design Temperature (Int/ Ext) °C 85 / 85 confirmed
2.10 MDMT °C -10 confirmed
2.11 MAWP barg VTA
2.12 Radiography / UT As per UL 142 confirmed
2.13 Post Weld Heat Treatment NA
2.14 Insulation No
2.15 Fire Proofing No
3.0 Mechanical Data
3.1 Capcaity m3 5 Confirmed
3.2 Size mm ID 1500 x 3062L Confirmed
3.3 Orientation Horizontal Confirmed
6.0 Documentation
6.1 Documentation as per Data Sheet Required
7.0 Guarantees
7.1 Mechanical Design Guarantee Required Confirmed
Technical Acceptance