You are on page 1of 38

EE2804 – Applied Electricity

AC and DC motors
Semester 03

Instructed by: Ms. P.G.A. Perera

Group Members: Name : De Silva T.D.H.

WICRAMASINGHE M.S. 200714V Index No. : 200756B


WITHANAGE W.D.A.S. 200738X
PERERA K.G.A.A. 200747A Group : G08
DE SILVA T.D.H. 200756B
PUNSARA H.E.R. 200764X Date of Per. : 27-11-2022
NANDASIRI P.H.G.A. 200412T
Date of Sub. : 10-11-2022
shaded pole motor

Capacitance (μF) Voltage (V)


2 31.2
3 24.4
4 22.2
5 21.9
6 19.6
7 23.8
8 25.1
9 26.02
10 26.63
For Running Winding,

Direct Current

V(V) I(A)
30 0.128
25 0.106
20 0.086
15 0.068
10 0.044
5 0.022
0 0
For Running Winding,

Alternative Current

V(V) I(A)
130 0.152
120 0.142
110 0.132
100 0.118
90 0.104
80 0.096
70 0.084
For Starting Winding,

Direct Current

V(V) I(A)
30 0.074
25 0.062
20 0.050
15 0.038
10 0.026
5 0.012
0 0.000
For Starting Winding,

Alternative Current

V(V) I(A)
130 0.142
120 0.132
110 0.120
100 0.110
90 0.100
80 0.088
70 0.078
Speed (rpm) Torque (Nm)
1300 16.30662
1420 14.83759
1500 13.36857
1580 11.89954
1660 10.98866
1740 9.519635
1860 8.050611
Torque (Nm) Armature Current (A)
16.30662 18.8
14.83759 17.8
13.36857 16.6
11.89954 15.9
10.98866 15.2
9.519635 14.2
8.050611 13.5
Speed (rpm) Armature Current (A)
1300 18.8
1420 17.8
1500 16.6
1580 15.9
1660 15.2
1740 14.2
1860 13.5
Efficiency Armature Current (A)
69.39905 18.8
68.48285 17.8
70.27877 16.6
66.44596 15.9
65.34615 15.2
63.55291 14.2
60.79666 13.5
Copper Loss Armature Current (A)
883.6 18.8
792.1 17.8
688.9 16.6
632.025 15.9
577.6 15.2
504.1 14.2
455.625 13.5
Mechanical Loss(W) Speed (rpm)
140.4301 1360
223.3196 1420
199.1702 1500
349.632 1560
423.2033 1640
479.2426 1720
544.6483 1840
REFERENCES

• Staff, E. (2016) Advantages & Disadvantages Induction Motor, Inst Tools. Available at:
https://instrumentationtools.com/advantages-disadvantages-induction-motor/ (Accessed:
November 10, 2022).
• Max (2022) Split phase induction motors: Types, working & performance, linquip. Available
at: https://www.linquip.com/blog/split-phase-induction-
motors/#:~:text=The%20split%2Dphase%20induction%20motor%20has%20lower%20p.f.%20
and%20lesser,of%20the%20low%20starting%20torque. (Accessed: November 10, 2022).
• Ayothi, M. (2020) Shaded pole induction motor, working, Advantages, Power Rating,
Electrical4u. Available at: https://www.electrical4u.net/induction-motor/shaded-pole-
induction-motor-working-advantages-power-rating/ (Accessed: November 10, 2022).
DECLARATION

I T.D.H. De Silva (Index No. 200756B ), hereby declare that this coursework entitled, AC and DC
motors is my own course work, which is prepared by me towards the module EE2804 This does not
incorporate any material written/ submitted or published by another person except where the
acknowledgement is made in the text.

…2022/11/10…….
Date Student Signature

REMARKS

Observations

Graphs

Calculations

Discussion

Other Comments

Marked by: ……………………………………

…………………… …………………………
Date Signature

Feedback received.