■ Overview
• The space-saving basic versions
• Interface for the connection of expansion modules, up to 24
digital inputs, 16 digital outputs, 8 analog inputs and 2 analog
outputs can be addressed
2
• With connection option for LOGO! TD text display (can be
connected to all LOGO! 0BA6 basic versions)
■ Technical specifications
6ED1 052-1CC00-0BA6 6ED1 052-1MD00-0BA6 6ED1 052-1HB00-0BA6 6ED1 052-1FB00-0BA6
Supply voltages
Rated value
• DC 12 V Yes
• DC 24 V Yes Yes Yes
• DC 115 V Yes
• DC 230 V Yes
• permissible range, 20.4 V 10.8 V 20.4 V 100 V
lower limit (DC)
• permissible range, 28.8 V 28.8 V 28.8 V 253 V
upper limit (DC)
• AC 24 V Yes
• AC 115 V Yes
• AC 230 V Yes
• permissible range, 20.4 V 85 V
lower limit (AC)
• permissible range, 26.4 V 265 V
upper limit (AC)
Time
Time switching clocks
• Power reserve 80 Hours 80 Hours 80 Hours
Digital inputs
Number of digital inputs 8; of which 4 can be used as 8; of which 4 can be used as 8 8
analog (0...10V) analog (0...10V)
Digital outputs
Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay
Short-circuit protection of Yes; electrical (1 A) No; external fusing No; external fusing No; external fusing
the output necessary necessary necessary
Relay outputs
Switching capacity of the
contacts
• with inductive load, max. 3A 3A 3A
• with resistive load, max. 0.3 A 10 A 10 A 10 A
■ Overview
• The space-saving basic variants
• Interface for the connection of expansion modules, up to 24
2 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog
outputs can be addressed.
SIPLUS LOGO! 24 SIPLUS LOGO! 12/24RC SIPLUS LOGO! 24RC SIPLUS LOGO! 230RC
Order No. 6AG1 052-1CC00-2BA5 6AG1 052-1MD00-2BA5 6AG1 052-1HB00-2BA5 6AG1 052-1FB00-2BA5
Order No. based on 6ED1 052-1CC00-0BA5 6ED1 052-1MD00-0BA5 6ED1 052-1HB00-0BA5 6ED1 052-1FB00-0BA5
Ambient temperature range - 25 ... + 70 °C
- 25 ... +55 °C (for applications with cUL approval), condensation permissible
Environmental conditions Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere)
Approvals CE, cUL
Technical data The technical data are identical with those of the based-on modules.
■ Technical specifications
6AG1 052-1CC00-2BA5 6AG1 052-1MD00-2BA5 6AG1 052-1HB00-2BA5 6AG1 052-1FB00-2BA5
Supply voltages
Rated value
• DC 12 V Yes
• DC 24 V Yes Yes Yes
• DC 115 V Yes
• DC 230 V Yes
• permissible range, 20.4 V 10.8 V 20.4 V 100 V
lower limit (DC)
• permissible range, 28.8 V 28.8 V 28.8 V 253 V
upper limit (DC)
• AC 24 V Yes
• AC 115 V Yes
• AC 230 V Yes
• permissible range, 20.4 V 85 V
lower limit (AC)
• permissible range, 26.4 V 265 V
upper limit (AC)
Time
Time switching clocks
• Power reserve 80 Hours 80 Hours 80 Hours
Digital inputs
Number of digital inputs 8; of which 2 can be used as 8; of which 2 can be used as 8 8
analog (0...10V) analog (0...10V)
■ Overview
• The cost-optimized basic versions
• Interface for the connection of expansion modules, up to
24 digital inputs, 16 digital outputs, 8 analog inputs and
2 analog outputs can be addressed
2
• With connection option for LOGO! TD text display (can be
connected to all LOGO! 0BA6 basic versions)
■ Technical specifications
6ED1 052-2CC00-0BA6 6ED1 052-2MD00-0BA6 6ED1 052-2HB00-0BA6 6ED1 052-2FB00-0BA6
Supply voltages
Rated value
• DC 12 V Yes
• DC 24 V Yes Yes Yes
• DC 115 V Yes
• DC 230 V Yes
• permissible range, 20.4 V 10.8 V 20.4 V 100 V
lower limit (DC)
• permissible range, 28.8 V 28.8 V 28.8 V 253 V
upper limit (DC)
• AC 24 V Yes
• AC 115 V Yes
• AC 230 V Yes
• permissible range, 20.4 V 85 V
lower limit (AC)
• permissible range, 26.4 V 265 V
upper limit (AC)
Time
Time switching clocks
• Number 8 8 8
• Power reserve 80 Hours 80 Hours 80 Hours
Digital inputs
Number of digital inputs 8; of which 4 can be used as 8; of which 4 can be used as 8 8
analog (0...10V) analog (0...10V)
Digital outputs
Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay
Short-circuit protection of Yes; electrical (1 A) No; external fusing No; external fusing No; external fusing
the output necessary necessary necessary
Relay outputs
Switching capacity of the
contacts
• with inductive load, max. 3A 3A 3A
• with resistive load, max. 0.3 A 10 A 10 A 10 A
■ Overview
• Basic variants optimized for costs
• Interface for the connection of expansion modules, up to
2 24 digital inputs, 16 digital outputs, 8 analog inputs and
2 analog outputs can be addressed.
• Ambient temperature range -40 °C to +70 °C with 3 types
SIPLUS LOGO! 24o SIPLUS LOGO! 12/24RCo SIPLUS LOGO! 24RCo SIPLUS LOGO! 230RCo
Order No. 6AG1 052-2CC00-2BA5 6AG1 052-2MD00-2BA5 6AG1 052-2HB00-2BA5 6AG1 052-2FB00-2BA5
Order No. based on 6ED1 052-2CC00-0BA5 6ED1 052-2MD00-0BA5 6ED1 052-2HB00-0BA5 6ED1 052-2FB00-0BA5
Ambient temperature range -25 ... +70 °C
-25 ... +55 °C (for applications with cUL approval), condensation permissible
Environmental conditions Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere)
Approvals CE, cUL
Technical data The technical data are identical with those of the based-on modules.
■ Technical specifications
6AG1 052-2CC00-2BA5 6AG1 052-2MD00-2BA5 6AG1 052-2HB00-2BA5 6AG1 052-2FB00-2BA5
6AG1 052-2CC00-2BY5 6AG1 052-2HB00-2BY5 6AG1 052-2FB00-2BY5
Supply voltages
Rated value
• DC 12 V Yes
• DC 24 V Yes Yes Yes
• DC 115 V Yes
• DC 230 V Yes
• permissible range, 20.4 V 10.8 V 20.4 V 100 V
lower limit (DC)
• permissible range, 28.8 V 28.8 V 28.8 V 253 V
upper limit (DC)
• AC 24 V Yes
• AC 115 V Yes
• AC 230 V Yes
• permissible range, 20.4 V 85 V
lower limit (AC)
• permissible range, 26.4 V 265 V
upper limit (AC)
■ Overview
• Expansion modules for the connection to LOGO! Modular
• With digital inputs and outputs, analog inputs or analog
outputs 2
■ Technical specifications
6ED1 055-1CB00-0BA0 6ED1 055-1HB00-0BA0 6ED1 055-1MB00-0BA1 6ED1 055-1FB00-0BA1
Supply voltages
Rated value
• DC 12 V Yes
• DC 24 V Yes Yes Yes
• DC 115 V Yes
• DC 230 V Yes
• permissible range, 20.4 V 20.4 V 10.8 V 100 V
lower limit (DC)
• permissible range, 28.8 V 28.8 V 28.8 V 253 V
upper limit (DC)
• AC 24 V Yes
• AC 115 V Yes
• AC 230 V Yes
• permissible range, 20.4 V 85 V
lower limit (AC)
• permissible range, 26.4 V 265 V
upper limit (AC)
Digital inputs
Number of digital inputs 4 4 4 4
Digital outputs
Number of digital outputs 4 4; Relay 4; Relay 4; Relay
Short-circuit protection of Yes; electrical (1 A) No; external fusing No; external fusing No; external fusing
the output necessary necessary necessary
Relay outputs
Switching capacity of the
contacts
• with inductive load, max. 3A 3A 3A
• with resistive load, max. 5A 5A 5A
• Thermal continuous 0.3 A
current, max.
EMC
• Emission of radio interfe- Yes Yes Yes Yes
rence to EN 55 011 (limit
class B)
6ED1 055- 6ED1 055- 6ED1 055- 6ED1 055- 6ED1 055- 6ED1 055-
1CB10-0BA0 1NB10-0BA0 1FB10-0BA0 1CB10-0BA0 1NB10-0BA0 1FB10-0BA0
Supply Digital inputs
voltages
Number of 8 8 8
Rated value digital inputs
• DC 24 V Yes Yes Input voltage
• DC 115 V Yes • for signal "0" < 5 V DC < 5 V DC < 40 V AC;
< 30 V DC
• DC 230 V Yes
• for signal "1" > 12 V DC > 12 V DC > 79 V AC;
• permissible 20.4 V 20.4 V 100 V > 79 V DC
range, lower
limit (DC) Input current
• permissible 28.8 V 28.8 V 253 V • for signal "0", 1 mA 1 mA 0.03 mA
range, upper max. (permis-
limit (DC) sible quiescent
current)
• AC 115 V Yes
• for signal "1", 2 mA 2 mA 0.08 mA
• AC 230 V Yes typ.
• permissible 85 V Input delay (for
range, lower rated value of
limit (AC) input voltage)
• permissible 265 V • for standard
range, upper inputs
limit (AC)
- at "0" to "1", 1.5 ms 1.5 ms 50 ms
• permissible 47 Hz max.
frequency - at "1" to "0", 1.5 ms 1.5 ms 50 ms
range, lower max.
limit
• permissible 63 Hz
frequency
range, upper
limit
■ Overview
• Expansion modules for connection to LOGO! Modular
• With digital inputs and outputs, analog inputs, or analog
2 outputs
• Ambient temperature range -40 °C to +70 °C with 5 types
SIPLUS LOGO! DM8 SIPLUS LOGO! DM8 SIPLUS LOGO! DM8 SIPLUS LOGO! DM8 SIPLUS LOGO! DM8
24 12/24 24R 12/24R 230R
Order No. 6AG1 055-1CB00- 6AG1 055-1PB00- 6AG1 055-1HB00- 6AG1 055-1MB00- 6AG1 055-1FB00-
2XB0 2XB0 2XB0 2XB1 2XB1
12/24 V DC power
supply
Order No. based on 6ED1 055-1CB00- 6ED1 055-1CB00- 6ED1 055-1HB00- 6ED1 055-1MB00- 6ED1 055-1FB00-
0BA0 0BA0 0BA0 0BA1 0BA1
Ambient temperature range -25 ... +70 °C
-25 ... +55 °C (for applications with cUL approval), condensation permissible
Environmental conditions Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere)
Approvals CE, cUL
Technical data The technical data are identical with those of the based-on modules.
SIPLUS LOGO! DM8 SIPLUS LOGO! DM8 SIPLUS LOGO! DM8 SIPLUS LOGO! DM8 SIPLUS LOGO! AM2
24 24R 12/24R 230R
Order No. 6AG1 055-1CB00- 6AG1 055-1HB00- 6AG1 055-1MB00- 6AG1 055-1FB00- 6AG1 055-1MA00-
2BY0 2BY0 2BY1 2BY1 2BY0
Order No. based on 6ED1 055-1CB00- 6ED1 055-1HB00- 6ED1 055-1MB00- 6ED1 055-1FB00- 6ED1 055-1MA00-
0BA0 0BA0 0BA1 0BA1 0BA0
Ambient temperature range -40 ... +70 °C
-40 ... +55 °C (for applications with cUL approval), condensation permissible
Environmental conditions Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere)
Approvals CE, cUL (available soon)
Technical data The technical data are identical with those of the based-on modules.
• For communication between the LOGO! master and external Dimensions (W x H x D) in mm 36 (2 TE) × 90 × 55
EIB components through EIB
■ Application
24 V range. A LED indicates whether the output voltage is o.k.,
and in the event of an overload or short-circuit, the primary swit-
2 ched-mode regulators supply a constant current, that is, without
restart attempts.
LOGO!Power naturally supplies the small LOGO! control
modules. But these power supplies can also be used elsewhere.
As well as being system power supplies, the LOGO!Power
modules are also suitable for supplying other loads in the low-
end performance range. With the wide-range input 85 V to
264 V AC and radio interference level B, they can be used
universally in the most diverse application areas in the low-end
performance range. Because the benefits of the primary
switched-mode regulators convince all along the line.
For example:
• Improved protection of connected loads through the regulated
output voltage
• Low power losses in the control cabinet thanks to high
efficiency
The power supplies of the LOGO!Power range are primary
switched-mode devices that are optimally matched to the • Compact design and low weight.
LOGO! logic modules in their functionality and design. And LOGO!Power is also predestined for networking devices in
Depending on the power rating required, the LOGO!Power units standard low-voltage distribution boards
are available in two sizes and the new generation is now even • Can be installed on 35-mm mounting rail
more compact despite increased functionality. The width of the • Low installation depth and stepped profile of the design.
small version is only 54 mm instead of 72 mm and the large size
has shrunk from 126 mm to 72 mm. An extremely compact 4 A The power supplies naturally comply with the relevant European
power supply with a width of only 90 mm now supplements the and American regulations.
Dimensions (W x H x D) in mm 54 x 90 x 55 72 x 90 x 55 90 x 90 x 55
Weight, approx Approx. 0.17 kg Approx. 0.25 kg Approx. 0.34 kg
Installation Snaps onto DIN rail 60715 Snaps onto DIN rail EN 60715 Snaps onto DIN rail EN 60715
35x7,5/15 35x7,5/15 35x7,5/15
2 Dimensions
Weights
• Weight, approx. 160 g 160 g
LOGO! Software
Minimum system requirements
■ Overview
Windows 98 SE, NT 4.0, ME, 2000, XP or Vista (not 64-bit)
• PC Pentium
• 90 MB free disk capacity
• 64 MB RAM
• SVGA graphics card with minimum resolution 800x600
(256 colors)
Mac OS X
• PowerMac G3, G4, G4 Cube, IMac, PowerBook G3, G4 or
iBook.
Linux (tested with Caldera OpenLinux 2.4)
• Runs on all Linux distributions on which the Java 2 SDK
Version 1.3.1 runs.
• Please refer to your relevant Linux distribution for the
necessary hardware requirements.
■
2/28 Siemens ST 70 · 2009