Professional Documents
Culture Documents
43
PIPING FITTINGS COMPONENTS PIPING SPECIALTY COMPONENTS INSTRUMENT IN-LINE COMPONENTS INSTRUMENT ACTUATORS INSTRUMENTS 43
42
CONCENTRIC REDUCER 42
OPEN TUNDISH CORIOLIS FLOW INSTRUMENT H
DISCRETE SINGLE FUNCTION
ECCENTRIC REDUCER FLAME ARRESTOR I HIPPS IN LCR
FIELD MOUNTED
41 ANNUBAR FLOW INSTRUMENT DIAPHRAGM P 41
AIR INLET
CLOSED TUNDISH
M
40 M MAGNETIC FLOW INSTRUMENT 40
HOSE CONNECTION FLAME ARRESTOR DISCRETE FIELD MOUNTED S MSC IN CCR
ELECTRIC DIAPHRAGM C
UNDERGROUND BASIN WITH COVER
39 WELDED CAP 39
POSITIVE DISPLACEMENT FLOW INSTRUMENT
M U
DISCRETE SINGLE FUNCTION
CHAIN RETAINED CAP EXPANSION JOINT C UCP IN LCR
UNDERGROUND DRAIN HUB MOTOR INACCESSABLE IN PRIME LOCATION
38 P 38
TURBINE METER
HINGED JOINT U
37 UNDERGROUND GULLY WITH CATCH BASIN S DCS FUNCTION INACCESSABLE 37
SCREWED CAP C UCP IN LCR AND PDCA IN CCR
SOLENOID IN PRIME LOCATION
ULTRASONIC FLOW INSTRUMENT P
36 PLUG SILENCER 36
UNDERGROUND GULLY WITHOUT CATCH BASIN
DISCREET SINGLE FUNCTION
TERMINATION POINT VARIABLE AREA FLOW INSTRUMENT INACCESSABLE IN AUXILLIARY
35 PISTON 35
LOCATION
UNDERGROUND MANHOLE
CONTINUATION POINT VENT SILENCER
VORTEX FLOW INSTRUMENT
34
TEMPORARY TERMINATION POINT
DCS FUNCTION INACCESSABLE
IN AUXILLIARY LOCATION
INSTRUMENT LOGIC 34
TRAP
20 PLC FUNCTION INACCESSABLE 20
WATER AFFF HOSE REEL PITOT VENTURI TUBE
PD PULSATION DAMPER IN AUXILLIARY LOCATION
VENTURI TUBE
19 19
AIR RELEASE TRAP ORIFICE PLATE
ACCESS FITTING PLC FUNCTION ACCESSABLE
DUAL AGENT HOSE REEL
IN AUXILLIARY LOCATION
18 18
T STEAM TRAP ORIFICE PLATE WITH FLANGES MAGNETIC FLOW INSTRUMENT
IBT INVERTED BUCKET TRAP BULLS EYE INDICATOR INSTRUMENT FUNCTIONS TURBINE METER PLS FUNCTION ACCESSABLE IN LCR
15 15
FOAM CHAMBER
FLEXIBLE HOSE PLUS
TDT THERMODYNAMIC TRAP B
14 14
M BMC IN LCR
MINUS C
FIRE MONITOR MANWAY
13 TST THERMOSTATIC TRAP TARGET FLOW INSTRUMENT 13
X MULTIPLY
T
MECHANICAL COUPLING C TCC IN CCR
12
FILTER ÷ DIVIDE C 12
M
MOTOR VALVE % PERCENTAGE
11 MICROFILTER B 11
MONITOR TOWER MF
ULTRASONIC FLOW INSTRUMENT M BMS IN LCR
SQUARE ROOT S
10 JACKETED PIPE 10
SUM
VENT B
WATER SPRAY NOZZLE M BMS IN CCR
9 HIGH SELECT S
9
PIPELINE
LOW SELECT
8 FLARE TIP C 8
FUSIBLE BULB SPRINKLER C CCS IN LCR
SIGHT GLASS K TIME DELAY S
7 7
I/I CURRENT TO CURRENT
SILENCER CONNECTION M
6
A MAS IN CCR 6
I/P CURRENT TO PNEUMATIC S
WATER SEAL WITH VENT
SPRAY NOZZLE
5
SUP SUPPRESS 5
Po No.
LEGEND VALID FOR DRAWINGS GENERATED IN SMARTPLANT P&ID.
NOTES: Contractor
4 4
1. FOR GENERAL NOTES AND SYMBOLS SEE DRG.
No. E002-XX-00-PE1000.001 / 2 / 3 / 4 / 5 / 6.
2. ALL PROCESS AREA AUTOMATED BLOWDOWN VALVES FOR OTHER P&ID'S USE THE RESPECTIVE LEGEND. M.W.Kellogg Ltd
3 TO FLARE TO BE LOCATED AT A HIGH POINT ABOVE FLARE HEADER. 3
Vendor drawing No.