Professional Documents
Culture Documents
Pollution Wear
Diagnostic
Water content ppm TAN mg KOH/g Fe ppm Si ppm
50 0,2 15
40 0,15
10
30
0,1
20
5
10 0,05
0 0 0
0815765 0815765
This document is issued by the Company under its General Conditions of Service accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein.
Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s
sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration,
forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS Qualitest Spa Laboratoire OCM Agence Hassi Messaoud BP 997 Ouargla Algérie Tél: (213) 29 79 70 55 Fax: (213) 29 79 70 54
RESULTATS
Ordre 1
Echantillon 0815765
Type de prélèvement Prélèvement
Date de prélèvement 17/05/2023
Date de réception 24/05/2023
Date de diagnostic 24/05/2023
hours Equipement -
hours Huile 250
Appoint (l) -
Viscosity 40 ºC
Viscosity 40°C mm²/s 232.97
Water Content
Water content ppm 46
TAN ASTM D 664
TAN mg KOH/g 0.17
Spectrometry
Ag ppm 0
Al ppm 1
B ppm 2
Ba ppm 3
Ca ppm 13
Cd ppm 0
Cr ppm 0
Cu ppm 1
Fe ppm 13
K ppm 0
Lithium ppm 0
Mg ppm 4
Mn ppm 0
Mo ppm 1
Na ppm 6
Ni ppm 1
P ppm 256
Pb ppm 0
Sb ppm 0
Si ppm 4
Sn ppm 0
Ti ppm 0
V ppm 1
Zn ppm 11