You are on page 1of 2

Transducers employed in the bulk of enzyme electrodes use which of the following principles?

a) Amperometric b) Optical c) Magnetic d) Colorimetric


Given below is the diagram of biosensor. Identify the unmarked component.

a) Filter b) c) d) A/D converter


Transduce Microproce
r ssor
The nature of an enzyme is __________
a) Lipid b) c) d) Protein
Vitamin Carbohydra
te
_________ device is used for torque measurement.
a) Helical spring b) c) Flat d) Diaphragm
Bellows spiral
spring
Wearable health devices can help your doctor in all of the following ways except which one?
a) Monitor b) c) Monitor d) Monitor weight
activity levels Monitor disease
heart rate progression
trends
_______________ is responsible for generating blood pressure.
a) Contraction of b) c) d) Relaxation of
atria Contractio Relaxation ventricles
n of of atria
ventricles

List the method to measure glucose with the help of amperometric biosensor.

Mention the types of electrodes used in biomedical measurements.

Give the applications of biosensors in different fields.

the pros and cons of wearable healthcare technology.

frequency bands of EEG signals

Identify different sources of biomedical signals with respect to heart, brain, muscle and describe
it.
Interpret the blood pressure measured by indirect method.

Differentiate between active and passive bio signals.


1. A male clerk comes for diabetes assessment. He walks 30 minutes per day and consumes
a health vegetarian diet. He does not smoke or take alcohol. Examine the different
components of a biosensor used for diagnosis and management.
2. Explain the classification of biosensors based on transducers with their transduction
principles with related examples.
3. Describe the nature of profile between product concentration vs substrate concentration at
different enzyme loading for an enzyme bio sensor.
4. Discuss the principle, construction and working of non-labeled and labeled
immunosensors.
Explain the specifications of the photoplethysmography, draw the electrical circuit and classify
the types of hardware devices are available in market.
5. Describe the types of wearable sensor with its working principle and fabrication of
wearable sensors.
6. Brief the international standard 12 lead system used to record ECG list and mention the
important characteristics of bioamplifier.
7. A patient is admitted to the Intensive Care Unit following convulsive status epilepticus
requiring intubation for airway protection. Analyze the recording EEG potential for