Selection of Line Insulation Glass - Porc - Composite
Selection of Line Insulation Glass - Porc - Composite
2020
Insulator type selection
Influence types on insulation:
11
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
3
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Detection of a damaged insulator
Cost for
Covered
inspection Glass Porcelain Composite
Glass
(labour)
Inspection USD
10 10 152,5 240
per km
13
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Internal puncture of insulator
- Cavities
- Micro-cracks
- Inclusions
14
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Internal puncture of insulator
High risk of punctures at depressurization
Usually composite insulators are not subjected to the risk of puncture as
electrodes of the different potential are disjointed by a long fiberglass rod.
Nevertheless the punctures in the form of holes in the body are detected in the
constructions, and then they can ensure the access of atmospheric moisture to the
rod and its further damage under the influence of created acids.
15
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Internal puncture of insulator
After internal puncture glass part damages, glass residue doesn’t split
When insulator is damaged, the residue (+ cap rod) withstands up to 80% of the
mechanical strength of the whole of insulator, there is no drop wires.
16
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Internal puncture of insulator
The most effective way for screening of toughened glass parts, containing the
inclusions, is the application of the certain thermal shocks for each unit before the
assembly stage. Such test is intended for destruction of the glass insulating part
containing the inclusions.
17
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Mechanical split of insulator
Only for porcelain and polymer insulators. Not typical for glass insulators.
Operation data testifies that the frequency of mechanical failures of the toughened
glass insulators for the last 50 years is extremely small - such as 1 on 10 million.
This situation, as a rule, is connected with the exclusive cases, such as the repeated
arcs fusing fittings or uncontrollable vibration of the phase conductors spreading to
insulating strings and leading to «de - capping».
18
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Mechanical split of insulator
19
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Mechanical split of insulator
20
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
Fractional damages and breakage of dielectric material
Only for porcelain and polymer insulators. Not for glass insulators.
This type of failure is observed mostly for porcelain insulators and usually called by
vandalism or irregular transportation, storage and mounting.
Unlike the toughened glass insulators, only some part of a porcelain disc is broken off
and the internal cracking cannot be easily detected.
21
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation
THANK YOU FOR YOUR ATTENTION!
QUESTIONS ?
24
GLOBAL INSULATOR GROUP/ Selection of line insulation in severe conditions of operation