You are on page 1of 1

Service Information System Page 1 of 1

Troubleshooting
C15 and C18 Engines for Caterpillar Built Machines
Media Number -SENR9748-07 Publication Date -01/11/2014 Date Updated -04/11/2014

i02445684

CID 0266 FMI 02 Incorrect Crank-without-inject inputs


SMCS - 1901-038

Conditions Which Generate This Code:

The crank without inject (NC) input and the crank without inject (NO) input are above 11.5 VDC or
below 0.5 VDC for two seconds. Both switch inputs may be detected as an open circuit for two seconds
or both switch inputs may be detected as a short circuit for two seconds.

System Response:

The "Crank w/o Injection" feature will be disabled.

l There are no performance effects.

Test Step 1. Perform the following diagnostic procedure: Crank Without Inject Circuit - Test

Results:

l OK - STOP

Copyright 1993 - 2018 Caterpillar Inc. Thu Sep 20 15:56:37 EST 2018