FOUNDATION LOADINGS

BEFORE CASTING THE FOUNDATION VERIFY THE DIMENSIONS OF THE WIND SPEED (M/SEC) 44
FOUNDATION BOLT (DIA.& QTY.) AND ANCHOR PLATE (PCD) WITH BENDING MOMENT (T-M) 178.108
RESPECT TO THE DIMENSIONS MENTIONED IN THIS DRG. HORIZONTAL SHEAR (T) 6.181
VERTICAL LOAD (T) 8.755
MAX GR BEARING
PRESSURE (T/M2) 17.286
1900 88 nos 12 tor (T1) SAFETY FACTOR AGAINST
OVERTURNING 0.836
CONCRETE MIX VIBRATED M-25
MIN COVER (MM) 50
1900

8 tor 190 c/c (T3) STEEL Fe-415


GROSS SBC (T/M2) 10.00
Bolt Nos. = 24 PROJECTED AREA (M2) 15.215
Bolt Dia. = 39 mm
DETAIL OF PEDESTAL Length = ### mm

1900

195 Anchor Pl. Thk.(mm) = 8 mm


PCD (mm) = 1350 mm
300

Nos.of hole/Dia.(mm) = 24 / 41

88 nos 12 tor (T1)


2000

8 tor 190 c/c (T3)


2500

22 nos 10 tor Bothways (T4)


400

SECTIONAL ELEVATION
PCC (1:4:8)
100

BAR BENDING SCHEDULE


100 4600 100 MK QTY SIZE LENGTH SHAPE
76 nos 10 tor Bothways (T2) 100

2575
SECTIONAL ELEVATION T1 88 12 2995

4600 320

100
T2 152 10 4700
4500
1800
24 nos.

1800
Bolts T3 15 8 7392
4600

100
T4 44 10 4700
4500
QUANTITIES
22 nos 10 tor Bothways (T4) RCC PCC STEEL
76 nos 10 tor Bothways (T2) (M3) (M3) (kg)

16.77 2.30 889.058


22 nos 10 tor Bothways (T4)
76 nos 10 tor Bothways (T2) NOTES
1- ALL DIMENSIONS ARE IN MM. DO NOT SCALE THE DRAWING
SECTIONAL PLAN 2- MIN. LAP LENGTH OF BARS SHALL BE 50xD. UNLESS OTHERWISE STATED.
3- WE RECOMMANDED THAT MAST FLANGE REMAIN UNGROUTED
4- IF GROUTING IS CARRIED OUT IT IS ESSENTIAL TO LEAVE A MINIMUM
OF 4 NOS 25MM DIA DUCTS EQUALLY SPACED AROUND THE FLANGE TO
ALLOW DRAINGE AND VENTILATION
REV DESCRIPTION DATE 5- BARS DRAWN IN THE DRAWING ARE FOR ILLUSTRATION ONLY. REFER TO
THE NUMBERS SHOWN FOR ACTUAL REINFORCEMENT QUANTITY.
This drawing is the property of "VMMPL" & must be returned on
request. It is submitted as confidential information in connection with enquiry, tender,
orders or contracts. It is not to be used for any other purpose or order nor may it re-
copied or lent without our authority in writing
DATE 29-12-23 TITLE: GA Civil Foundation Drawing for 45m Sheet No. Rev.
DRN BY AUTO High Mast 01 of 01 0
CHKD BY GK PROJECT: M/s-CIDCO DRAWING NUMBER: -
APPRD BY AU HM DESIGN CALCULATIONS
SCALE NTS

Page 1