MPH2™ MANAGED RACK PDU

Advanced Monitoring And Control Support

MPH2 is the most intelligent, high-availability line of managed


MPH2 BENEFITS
rack PDUs. It offers remote monitoring and control capabilities
yy Monitors electrical and as well as environmental input options, with multiple power input
environmental parameters with
user-configurable threshold and selections, output configurations, and form factors.
alarm tools

yy Controls and manages individual Models in 0U, 1U, and 2U form factors are available in the following versions:
receptacles and/or groups of loads
and devices yyOutlet Level Metered and Switched
yy Allows you to predict failing
conditions before they occur and yyOutlet Level Metered
proactively manage connected
equipment for maximum uptime yyRack PDU Metered and Outlet Switched
yy Energy and power metering to yyRack PDU Metered
optimize the data center power and
cooling infrastructure

yy Lowest power consumption of all


switched rack PDU designs ensures MPH2 Savings for a Typical Data Center
lower operating costs for datacenter
TYPICAL 24 OUTLET RACK PDU MPH2
yy Up to four MPH2 rack PDUs Rack PDU power consumption (Watts) 23 7.5
may be interconnected as a Rack
PDU Array™, consolidating user IP Rack PDU annual energy consumption (kWh) —24x7x365 202 66
connections and device monitoring. Overall contribution to datacenter energy consumption (kWh)* 383 125
Cost of energy consumption (based on average cost of 10¢/kWh) $38 $13
Designed for Critical
Annual savings per pdu with MPH2 $26
Environments
Annual savings per rack with MPH2 $52
yy Industry leading operating
temperature— up to 60˚C / 140˚F Annual savings within the datacenter with MPH2 $5,160
to support hot Internal
rack environments Based on a a comparison of switched rack PDU models for a typical 100 rack data center with a PUE of 1.9.
* per Energy Logic calculations

yy Bi-stable relays ensure basic power


distribution in the event that
intelligence is compromised

yy Accurate power metering of


+/-1% voltage & current for
assured oversight

yy Energy and power metering down


to the individual receptacle

yy Comprehensive alarming including


notification of overloaded
branch circuits

yy Environmental sensing with Also available in 1U and 2U models


threshold and alarm set-points

yy Notification on the loss or removal


of individual rack equipment loads

1
MPH2™ MANAGED RACK PDU

MPH2™ Specifications
Mounting Preinstalled Toolless brackets; Universal Mounting bracket; Standard 2 years; Extended Warranties
Ability to ship rack PDU preinstalled in Vertiv™ Racks Warranty Available
Input Power Options 100 - 120V 1-ph 20A/30A; 200 - 240V 1-ph 20/30A; 200 - 240V 3-ph 20/30/50/60A; Agency UL, CSA, CE, RoHS, REACH, FCC
North America 208/120V 3-ph 20/30A; 415V/240V 3-ph 20A/30A Approvals Class A, CB, WEEE, ISTA
Input Power Options 230V 1-ph 16A/32A; 230/400V 3-ph 16A/32A/63A Metering Levels Aggregate, Branch, Phase, Outlet
International
Parameters Volts, Current, kW, KVA, kWh,
Input Wiring Options 10 ft. pluggable power cord or Hardwired Measured Power Factor, Crest Factor,
Frequency
Max. Capacity 17.2 kW
North America Metering +/-1%
Accuracy
Max. Capacity 22.2 kW
International Switching On, Off, Recycle, Lock, Unlock,
Capability Outlet Grouping Capability
Outlet Options NEMA 5-20; IEC 320 C13; IEC 320 C19; Locking capability on all outlets
Modularity RPC2 communications module
Maximum Outlets Strip Metered: 42 Outlet Metered and / or Switched: 24
Local Onboard Display, Optional Local
Maximum Operating 0°C to 60°C (32°F to 140°F) Management Display
Temp. Range
Remote Onboard Web Interface; CLI;
Storage Temperature -25°C to 85°C (-13°F to 185°F) Management SNMP; SSH; Telnet Integration
Range with Avocent® ACS, Avocent
Relative Humidity 5% to 95% Universal Management Gateway &
Avocent MergePoint™ Unity
Overcurrent Protection Software Electronic Overcurrent Protection; 100% Rated 20A Branch Overcurrent Integration with DSView®, Rack
Protection - Hydraulic Magnetic Circuit Breakers Power Manager, Nform™ and the
Idle Power Consumption 3W - 5W Trellis™ platform

0U Units Width x Depth 0U Low profile: 56mm x 5mm(2.2in x 1.96in) SNMP version v1, v2 and v3
0U Standard: 56mm x 70mm(2.2in x 2.7in) support

0U units Length 916 mm / 1004 mm / 1737 mm/ 1827 mm; (36 in) / (39.5 in) / (68.4 in) / (72 in) Authentication Local Remote: Active Directory,
LDAP, TACACS, Radius, Kerberos
1U/2U Units Width 1U: 482.6mm x 44mm x 250mm (19in x 1.73in x 9.84in)
x Height x Depth 2U: 482.6mm x 88mm x 250mm (19in x 3.46in x 9.84in) Encryption MD5, AES, DES

Seamless DCIM Manageability and Integration


Locking outlets and DCIM
locking power cord - Avocent® Universal
Management Gateway
- Trellis™ Platform
RPC2™ Communications
BDM™ local Communications Module
Critical Equipment
display module Module (RPC2™)
Monitoring Solutions
- Liebert® Nform™
SN Sensors - Liebert SiteScan®
Onboard - 3rd party apps (SNMP)
display
Out of Band Access and
Flexible power Control Solutions Command Line
cord entry
Slim - Avocent Advanced Interface
profile Console Server
breakers - Avocent MergePoint® Unity
- Avocent DS View 4™

Centralized PDU
Management
Corded and
hardwired options - Rack Power Manager Web User Interface