Professional Documents
Culture Documents
Pumps APPLICATIONS
x Water supply from drilled wells, cisterns.
x Sprinkler irrigation.
x Pressure boosting.
x Fire-fighting.
SPECIFICATIONS CONSTRUCTION
CHARACTERISTICS
PUMP PUMP
x Delivery: x Abrasion-resistant construction.
up to 27 m3/h at 3500 rpm. The front wear ring, combined
x Head: with the floating impellers, ensures
up to 300 m at 3500 rpm. optimum resistance to sand
x Maximum pump overall diameter abrasion.
(cable cover included): 99 mm. x The upper and lower supports are
x Maximum immersion depth: made of precision-cast stainless
150 m (with 4OS motor). steel, ensuring resistance to
300 m (with L4C motor). corrosion, durability and a sturdy
x Maximum permissible quantity of coupling to the motor.
sand: 150 g/m3. x The hexagonal pump shaft
x 1GSL - 2GS - 4GS - 6GS guarantees an effective impeller
versions: driving.
Rp 1 1/4 delivery port. x Stainless steel non-return valve
x 8GS - 12GS - 16GS versions: integrated in the head
Rp 2 delivery port. x The e-GS series pumps can be
• Motor power: coupled to either the 4OS or
from 0,37 to 7,5 kW. L4C motors.
MOTOR MOTOR
x 4OS single-phase version: For the motor features, please refer
from 0,37 to 2,2 kW 220-230 V,60 Hz. to the specific technical brochures.
x 4OS three-phase version:
from 0,37 to 7,5 kW 220-230 V,60 Hz. OPTIONAL
from 0,37 to 7,5 kW 380 V,60 Hz. FEATURES
x L4C single-phase version: • Different voltages and frequencies.
from 0,37 to 4 kW 220-230 V,60 Hz. • Motor with built in capacitor
x L4C three-phase version: (2W = Two Wires)
from 0,37 to 5,5 kW 220-230 V,60 Hz. • Cooling sleeves
• Abrasion resistant from 0,37 to 7,5 kW 380 V,60 Hz.
x Maximum supply voltage
variations:
• Floating impellers
±10% (4OS)
±6% (L4C).
• Compact x Maximum number of starts
for hour evenly distributed:
30 (4OS)
• Ecodesign 40 (L4C).
compliant MEI ≥ 0,4 x Horizontal operation:
4OS up to 2,2 kW.
• Approvals L4C up to 7,5 kW.
x Maximum temperature of water
- ACS in contact with motor:
- D.M.174/2004 35°C
e-GS SERIES
PUMP SECTION
1 16
2 17
3 10
4 18
5 19
6 20
7 21
8 11A 23
9 18 24
10 22 25
11 23 26
12 17 27
13 11
14
15
A0031_A_SC
e-GS SERIES
TABLE OF MATERIALS
5() 1$0( 0$7(5,$/ 5()(5(1&(67$1'$5'6
1 (8523( 86$
9DOYHFDS 6WDLQOHVVVWHHO (1;&U1L $,6,
9DOYHJDVNHW 1%5
9DOYHIODQJH 6WDLQOHVVVWHHO (1;&U1L $,6,
9DOYHORFNLQJULQJ 6WDLQOHVVVWHHO ',1;&U1L $,6,
$GDSWHUULQJ 7HFKQRSRO\PHU332
8SSHUEXVKEUDFNHW 7HFKQRSRO\PHU332
7KUXVWEHDULQJ 6WDLQOHVVVWHHO (1;&U1L $,6,
:DVKHU 6WDLQOHVVVWHHO (1;&U1L $,6,
,QWHUPHGLDWHEXVKEUDFNHW 7HFKQRSRO\PHU332
6KDIWVOHHYH 6WDLQOHVVVWHHO (1;&U1L $,6,
6OHHYH 6WDLQOHVVVWHHO (1;&U1L $,6,
$ 8SSHUVOHHYH 6WDLQOHVVVWHHO (1;&U1L $,6,
3XPSVKDIW 6WDLQOHVVVWHHO (1;&U1L $,6,
&RXSOLQJ 6WDLQOHVVVWHHO (1;&U1L $,6,
6WUDLQHU 6WDLQOHVVVWHHO (1;&U1L $,6,
0RWRUDGDSWHU 6WDLQOHVVVWHHO (1*;&U1L &)$670$
'LVFKDUJHKHDG 6WDLQOHVVVWHHO (1*;&U1L &)$670$
6FUHZVQXWVZDVKHUV 6WDLQOHVVVWHHO (1;&U1L0R $,6,
%XVK 7HFKQRSRO\PHU38
'LIIXVHU 7HFKQRSRO\PHU332
,PSHOOHU 7HFKQRSRO\PHU332
%RZO 6WDLQOHVVVWHHO (1;&U1L $,6,
,QWHUPHGLDWHEXVKEUDFNHW 6WDLQOHVVVWHHO (1*;&U1L &)$670$
&DEOHJXDUG 6WDLQOHVVVWHHO (1;&U1L $,6,
6KLP 6WDLQOHVVVWHHO (1;&U1L $,6,
8SSHUSXPSVKDIW 6WDLQOHVVVWHHO (1;&U1L $,6,
,QWHUPHGLDWHFRXSOLQJ 6WDLQOHVVVWHHO (1;&U1L0R $,6,
6SDFHU 6WDLQOHVVVWHHO (1;&U1L $,6,
Gs4-2p50-en_e_tm
e-GS SERIES
IDENTIFICATION CODE (PUMP)
6 G S 4 0 6 R / B
Frequency
Motor power kW x 10
[6] = 60 Hz
EXAMPLE: 6GS406R/B
e-GS SERIES
IDENTIFICATION CODE (ELECTRIC PUMP)
8 G S 5 5 6 R T / B - L 4 C
Flow rate
[8] = 8 m3/h Type of motor
[4OS] = Motor 4OS
[L4C] = Motor L4C
Name
[GS] = e-GS Series Version
[GSL] = e-GSL Series [/_] = Version
Power supply
Motor power kW x 10 [M] = Single-phase
[T] = Three-phase
Type of stages
Frequency
[Null] = Standard number of stages
[6] = 60 Hz
[R] = Number of stages reduced
EXAMPLE: 8GS55RT/B
LEGEND
1 - Pump / electric pump type
2 - Code
3 - Delivery range
4 - Head range
5 - Characteristics motor
6 - Manufacturing data and serial number
7 - Maximum immersion depth
8 - Speed
9 - Rated output
LEGEND
1 - Motor type
2 - Code
3 - Electrical data
4 - Characteristics motor
5 - Motor weight
6 - Service factors
7 - Maximum immersion depth
8 - Speed
9 - Temperature and speed water
10 - Capacitor data
12GS SERIES
OPERATING CHARACTERISTICS AT 60 Hz
3803 12) 02725 4 '(/,9(5<
7<3( 67$*(6 32:(5 OPLQ
PK
N: +3 + 727$/+($'0(75(6&2/8012):$7(5
*6
*6
*6
*6
*6
*6
+\GUDXOLFSHUIRUPDQFHVLQFRPSOLDQFHZLWK,62*UDGH% H[,62$QQH[$ JVSHQBGBWK
Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ ϲϬ ϳϬ
Y/ŵƉŐƉŵ
Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ ϲϬ ϳϬ ϴϬ Yh^ŐƉŵ
ϮϬϬ
ϭϮ'^ϳϱϲ
ϲϬϬ
ϭϴϬ
ϭϲϬ
ϱϬϬ
ϭϰϬ ϭϮ'^ϱϱϲ
ϭϮϬ ϰϬϬ
,Ĩƚ
,ŵ
ϭϬϬ ϭϮ'^ϰϬϲ
ϯϬϬ
ϴϬ ϭϮ'^ϯϬϲ
ϲϬ ϭϮ'^ϮϮϲ ϮϬϬ
ϰϬ ϭϮ'^ϭϱϲ
ϭϬϬ
ϮϬ
Ϭ Ϭ
ϳϬ
ηP[%]
ϲϬ
ɻй
ϱϬ
ϰϬ
ϭϮ'^ͺϮWϲϬͺͺ,
Ϭ Ϯ ϰ ϲ ϴ ϭϬ ϭϮ ϭϰ ϭϲ ϭϴ ϮϬ ϯͬŚ
Yŵ
These performances are valid for liquids with density U = 1.0 Kg/dm3 and kinematic viscosity Q = 1 mm2/sec.
SUBMERSIBLE ELECTRIC PUMP INSTALLATION
DIAGRAM
2
10 m
2
COMPONENTS REQUIRED FOR
1 13 CORRECT INSTALLATION
TECHNICAL APPENDIX
EXAMPLE OF INSTALLATION OF A SUBMERSIBLE
ELECTRIC PUMP CONTROLLED BY AN INVERTER
16 15 12
6 8 4 9 14 10 11
2
4
3 m (A)
2
10 m
3
1 - Submersible electric pump.
2 - Cable clamp.
3 - Level sensors for protection against
dry running.
2 4 - Non-return valve.
5 - Support bracket.
1 13 6 - Delivery pipe.
7 - Electrical cable for motor power
8 - Electric pump bleed/priming cap.
9 - Pressure gauge.
10 - Diaphragm tank
11 - Gate valve.
12 - Control panel.
13 - PTC/PT100 cable
14 - Pressure transducer.
15 - Inverter (Hydrovar or ResiBoost).
16 - Filter (suggest for cable lenghts
exceeding 20 meters.
TECHNICAL APPENDIX
CALCULATING THE SPEED OF THE FLUID
THAT FLOWS AROUND A SUBMERGED MOTOR
AND SIZING OF THE COOLING SLEEVE
Now, compare the speed thus calculated (v) with the minimum speed required for correct cooling of the motor
(vm): if v t vm it means that the motor is properly cooled, if v < vm will be necessary to mount a cooling sleeve (4).
Example:
An electric pump OZ630/12 (motor diameter d = 0.144 m) operates in an 8” well (well diameter D = 0.203 m)
with flow rate
Q = 20 m3/h = 0.0055 m3/s.
Speed of fluid v = (0.0055/2) / {S·[(0.203)2/4 – (0.144)2/4]} = 0.17 m/s.
The minimum speed required for proper motor cooling is vm = 0.20 m/s.
Because v < vm, it will be necessary to mount a cooling sleeve.
--------------------------------------------------------------------------------------------------------------------------------------------------------------
The following formula is used to determine the maximum § Q d2 ·
diameter of a cooling sleeve to be mounted on a submersible motor: D 4 ¨¨ ¸
© v S 4 ¸¹
Where: Q in [m3/s] is the operating flow rate of the electric pump; the entire flow is taken into account
because the fluid comes from the motor side (3) only;
D in [m] corresponds to the diameter of the cooling sleeve (4);
d in [m] corresponds to the diameter of the motors(3);
vm in [m/s] is the minimum speed of the fluid that flows around the motor.
If the electric pump operates at different flow rate, the minimum flow rate must be taken into account for
calculating the diameter of the cooling sleeve.
Example:
A motor coupled to the electric pump OZ615/24 (motor diameter d = 0.144 m), which operates with flow rate
Q = 15 m3/h = 0.0042 m3/s, requires a minimum speed of the fluid of vm = 0.20 m/s.
Cooling sleeve diameter D = {4·[(0.0042/(0.2·S)+(0.144)2/4] }0.5 = 0.217 m.
TECHNICAL APPENDIX