516 GR 70
516 GR 70
No JSPL/ANGUL/TDC-004807A
TECHNICAL DELIVERY CONDITIONS
Rev. 3
TSD-PLATE DIVISION FOR HOT ROLLED PLATES
ANGUL-ODISHA(INDIA) Date of Issue 24/08/2023
Customer Name :
Chemical Remarks
CE(IIW) = C+Mn/6+(Cr+Mo+V)/5 +(Ni+Cu)/15
*For each reduction of 0.01 percent point below the specified maximum of carbon as in ASME SA516 Gr 70, an increase of 0.06
percentage point above the specified maximum for manganese is permitted, up to a maximum of 1.50% by heat analysis and 1.60% by
product analysis. For Grade 60 plates 12.5 mm and under in thickness may have 0.85-1.20% manganese on heat analysis, and 0.79-
1.30% manganese on product analysis.
7
Mechanical Properties
YS (MPa) UTS (MPa) Elongation (%) (min) Bend Test (180°)
Sample Sample Internal Mandrel
Min Min Max GL=50 (mm) GL=200 (mm)
Orientation Orientation Radius
T 260 490 620 21 17 T 1.5t
Thick (mm) CVN Impact Test
Temp Energy (J) Energy (J) Sample
Min Max
(°C ) (minimum individual) (minimum average) Orientation
8 40 -46 16 20 L
40.01 50 -40 16 20 L
50.01 79.99 -35 16 20 L
Customer Name :
80 110 -29 16 20 L
200 BHN
9 ZTest
For, t > 100mm: Minimum reduction of area no less than 20 % as per ASTM A770
10
Test Sample Frequency in as supplied condition
Tensile Bend Impact Hardness ZTest Product Sample
1 sample per 1 sample per 1 sample per 1 sample per For, t > 100mm: 2 samples per 1 sample per
mother plate mother plate mother plate heat mother plate heat
11
Other Details
Dimensional Tolerance
TolThickness (mm) TolWidth TolLength Edge Condition
Maximum 0.2% of the actual length Maximum 1% of the actual width As per EN 10029 Class N Type L
Plate Inspection
Ultrasonic Inspection Visual Inspection
For, t <= 100 mm: As per EN 10204: 3.2 + IBR Form IV issued by JSP
Loose condition
For, t > 100 mm: As per EN 10204: 3.2 + IBR Form IV issued by BVIS
11
Plate Marking
Stencil Marking Hard Punching
Manufacture's Name Yes
Heat No. /Plate No. Yes Yes
Grade/Specification + ZT ( for t> 100 mm) Yes Yes
Size (Thickness x Width x Length) Yes
UT Level Yes
MT LTV Yes Yes
Customer Name :
Stenciling + hard punching shall be done on top surface of the plate at both ends.
13
Third party Inspection
By BVIS
Scope Of Inspection
Inspection and Testing Jindal TPI Witness
Product Analysis P Record Review (from MTC)
Mechanical Testing P RW ( 10% of the total no. of mother plates )
Dimensional Inspection P RW ( 10% of the total no. of plates )
Surface Inspection P RW ( 10% of the total no. of plates )
Ultrasonic Testing P RW ( 10% of the total no. of plates )
Marking P RW ( 10% of the total no. of plates )
Issue Of TC P Record Review
1. Any handwritten modification / comment in this document will make this document invalid and shall need reconfirmation from
Plant.
2. Steel is a technical product and any guarantee regarding the end application shall not come under JSP’s obligations. JSP shall fulfill
the properties as defined in this TDC only.
3. TC Remarks: TC will be Issued under the BIS certification marking license in IS2041 R260 indicating that this also certifies the
requirements of ASME SA516 Grade 70 (latest)
4. Mill Normalizing at 1.4 X thickness plus 10 minutes - minimum cycle time. (Target temp 880 +/-15° C)
5. Whenever the properties match with those of ASME SA516 Grade 60 viz. Chemistry is as per ASME SA516 Grade 60 and UTS
value is <= 540MPa, this would be maintained in the original test certificate itself under remarks column as – “The plates are
certified as per ASME SA516 Grade 60 also.”
6. Reduction ratio of cast slab to plate is >= 3.0 : 1 for plate thickness less than or equal to 100mm.
7. Reduction ratio of cast slab to plate is >= 2.0 : 1 for plate thickness greater than 100mm.
8. For plate thickness greater than 100mm the following test are done in addition as per ASME SA20 Clause 5.3
The plates are ultrasonically examined in accordance with Specification A578/A578M Level C based on Continuous scanning over
100 % of the plate surface.
The plates are through-thickness tension tested in accordance with Specification A770/A770M. ( Each tension test shall have a
minimum reduction of area no less than 20 %, Sample frequency: 2 samples per mother plate and Marked by stenciling as ZT on
plates )
Customer Name :