You are on page 1of 2

Bulletin 102222

Installation Instructions
0.3m(1ft) & 0.6m(2ft)

ValuLine™ Antennas Mount


Description 2
This antenna consists of a 0.3-metre (1-ft) / 0.6-metre (2ft)
reflector, radome, feed, and offset tower mount. The mount 6 5 4
is designed to attach the antenna to a vertical tower pipe of 3
diameter 48 to 115 mm (1.9 to 4.5"). The mount also 2 7
provides adjustment ranges of ±25° fine elevation and
±180° (±10° fine) azimuth.

Notice
The installation, maintenance, or removal of antenna
systems requires qualified, experienced personnel.
Andrew installation instructions have been written for
such personnel. Antenna systems should be inspected
once a year by qualified personnel to verify proper
installation, maintenance, and condition of equipment.

Andrew disclaims any liability or responsibility for the


results of improper or unsafe installation practices. 3

Apply loctite (8) to When fitting, torque nuts(4)


threads before to 22Nm (16.2lb-ft)

1a fitting to antenna

3
Slacken bolts 1/2 turn to adjust
azimuth (top & bottom) Rotate to
1 2
adjust
elevation

Slacken bolts 1/2 turn Rotate to adjust azimuth


to adjust elevation

0.3m (1ft) Application


(Single Pol version shown) Mount Assembly

Index
3

Antenna Antenna
offset left offset right

Table 2. Fastener Torque Specifications


Table 1. Antenna Parts list
Fastener Torque value in N·m (lb·ft ) for each fastener
Item Description Qty size

Size M5 M6 M8 M10 M12 M16


1 1ft or 2ft Reflector Assembly 1 Stainless 4.5 7.7 18.7 39.2 65.1 161
2 Pre-Assembled Mount Kit 1 steel (3.3) (5.7) (13.8) (28.9) (48) (118.7)
Galvanized 2.7 4.5 11.1 22 38 95
3 M10 X 35 c’sk skt hd screw,ss 3* steel (2) (3.3) (8.1) (16.2) (28) (70.1)
4 M10 Nut 4*
5 M10 lockwasher 4*
6 M10 flat washer 4*
7 Protective Cap 4*
8 loctite, tube 1/2ml 1* Warning: Use protective wear to avoid skin contact with the pre-applied
conductive grease on threads. Keep away from mouth. Wash thoroughly
after use with liberal amounts of liquid soap and rinse with water. Do not store
* Part of Pre-Assembled Mount Kit (item 2) open near food or food sources. Dispose of empty or partially filled containers
according to governmental regulations for petroleum products. Contents: oil,
clay, and zinc dust.

Andrew Corporation Telephone: 708/349-3300


10500 West 153rd Street FAX (U.S.A.): 1-800/349-5444 Printed in E.C. Apr'01
Orland Park, IL U.S. A. 60462 TELEX: 25-3897 Copyright © 1993 by Andrew Corporation