You are on page 1of 1

DOOR ACCESS SYSTEM TERMINATION DIAGRAM

14

Wiegand Connection BREAKGLASS

DC+(12V)

GND
NC C
Wiegand D0
Wiegand D1
12V DC(+)
12V DC( - )

COM
Wiegand Card Reader
NO NC

NO

K2 Exit Switch
GND

12V DC
POWER SUPPLY
PUSH

12V DC

GND

NO MAGNETIC LOCK
C

ADDRESS ELECTRONIC ENGINEER OWNER PROJECT TITLE SHEET CONTENTS DRAWING NO.
ROOM 401 - 402 OLYPIC BUILDING, 65 DOOR ACCESS LAYOUT

1
SEN GIL PUYAT AVENUE, MAKATI,
1235 METRO MANILA PROPOSED DOOR ACCESS SYSTEM & LAYOUT
WISC-VALOR SOUTHWOODS PROJECT
REG NO.: TIN:
CONTACT NO.
PTR NO.: DATE:
DRAWN BY: NICOLLE DEDORO CHECKED BY: ALDRIN CAMPOMANES APPROVED BY:
PLACE: LOCATION SOUTHWOODS Biñan City Laguna DATE: 08/04/2022 DATE: 08/04/2022 DATE:

You might also like