You are on page 1of 6

Multi Active

CONCEPTION Three Phase

UPS (Uninterruptible Power Supply)


Digital Signal Processor
Innovation, quality, technology
and reliability. Trademarks of
CM Comandos Lineares solutions

ABOUT THE With over 32 years in operation, CM Comandos is one of the


COMPANY largest UPS manufacturers in Latin America.

Moreover, it is the sole leader in solutions for the corporate market. Certified by
ISO-9001:2015 standards, CM Comandos stresses its commitment to excellence of
its products and full clients satisfaction

DOS L
AN I
M
N
CM CO

EA

ISO
RES

9001
2015
QUALIT Y

USAGE UPS of CM Comandos Lineares are suitable for critical-mission usage in all types of
corporations,
providing protection against power disturbances, such as cuts, micro cuts, noise, harmonic distortion,
spikes, transients, under and over voltage and frequency variations.

BENEFITS CM Comandos equipment operates with greater precision, adds more features
and are safer.
Features that create high reliability and productivity in many types of applications, diminish flaws and
hence maintenance costs. In short, being a CM Comandos client means having the return on capital
invested and guarantees that only a company with wide technical support can offer.

By choosing the brand CM Comandos Lineares you can count on the best
TECHNICAL
technical support prior and post-sales from a company that has established
SUPPORT
itself over these 30 years as the market leader.

State-of-the-art instrumentation, highly skilled workers, with national coverage and 24-hour service,
seven days a week, call center and certified processes ensure the excellence of our support services.
High Technology in
Digital Signal
Processing - DSP

We are living in an increasingly fast and practical world. A world connected by processors, chips, software and
peripherals. But this is still not enough. That is why the world is moving forward to immediately processing data
technologies. CM Comandos Lineares is one step ahead and offers its clients products with a revolutionary
technology, called Digital Signal Processing - DSP.

Today, this technology is present in the most sophisticated electronic systems due to its high speed and reliability.
Digital Signal Processors can process tens of millions of samples per second. This means real-time processing - the
signal is processed at the same time it is received, without delays or slowdowns.

THE MOST MODERN All the line of Multi Active UPS Conception has DSP
CORPORATE UPS technology. Feature that provides high performance and reliability

for critical-mission applications, i.e. it protects the applications where continuous operation is of critical importance.

Designed with heavy use of DSP technology resources, Multi Active UPS Conception adds new and advanced
features that create a new development concept, in which equipment firmware can be upgraded adding new
features in already installed units.

300kVA Model

If you are thinking about purchasing an


UPS, count on CM Comandos solutions ,
which ensures state-of-the-art
technology, maximum protection,
digital precision and real-time
processing.
Multi Active UPS Conception
Three Phase

DISPLAY TFT 4,3”


TOUCHSCREEN
ONLINE TECHNOLOGY WITH TOUCH COMMAND
STATIC MAINTENANCE BYPASS

Static Maintenance Bypass Static Bypass Present Mains


Protection system that,
It allows transfer and return of the UPS load to an alternate
in case of problems,
circuit of power supply for maintenance purposes. In any
automatically transfers
case, the power supply is continuous with no interruption.
the load to an alternate
circuit without breaking
the power supply.
Mains Failure

REMOTE
MANAGEMENT
Mains Input Output INTERFACE
They are made up of several tools. The
Inverter Static Bypass NetMate SNMP Adapter allows you to
It converts the direct current from the
rectifier or battery into alternating current remotely manage the UPS via the
Rectifier output, shaped like a pure sine wave,
Converts the energy disturbance-free. Internet through a web browser,
from the mains of the monitor status and send alerts via
utility provider or the
Battery bank
generator into direct
Stores backup power to power the UPS over a
email.
current, correcting or Maintenance Static IP Power software is a Windows
predetermined period, known as UPS runtime. Bypass
eliminating system
input disturbances. Application management tool and the
Client version is specific to automate
Input Alternating Current Output Alternating Current Maintenance Alternating Current
Static Bypass the shutdown of servers, being able to
Direct Current Alternating Current Static Bypass
automatically and simultaneously
disconnect multiple servers and
stations.
MAIN FEATURES The ArmModbus Adapter allows
integration of the UPS via a
Advanced Technology Display TFT 4,3" Touch Screen RS485, to Building Automation
DSP (Digital Signal Processor) (Standard Item) Systems.
Allows advanced and exclusive features in real Modern screen with touch commands, which
time. allows UPS access via the Internet

Internal Memory for 5 Thousand Records Possibility of DSP Firmware Upgrade


Allows tracking for analysis. Ensures the use and preservation of
investment.
True RMS Measurements with Multimeters
Accuracy DSP-Monitored Actions
They are ideal for non-linear load measurement. The actions are registered and recorded in the
event log.
Static Maintenance Bypass
Add protection and increase of sensitive load Smart Control of the Cooler Speed
reliability. They extend the life of equipment.

Real-Time Remote Management Software


Via TCP / IP with password protection for remote
access, shutdown.

Multi Active Parallel System (Exclusive CM)


It can be parallel as many units as needed,
allowing system expansion, according to
consumer demand.
SHUTDOWN INTERFACE AND REMOTE MANAGEMENT

A UPSMON Management Interface D UPSMON Remote Management Interface


E SNMP
Web Monitoring

PC with
Internet
B Interface Shutdown
F Interface Shutdown
G Software
integrating
all UPS monitoring

C Interface Shutdown
Client
LAN
H Software UPSMON
Remote Station with
internet connection

Multi-Servers
Multiplatform
DB9 Microprocessor Port Multi-O.S.
Ethernet Local Network RJ45 Ethernet Network

MULTI ACTIVE PARALLEL SYSTEM (EXCLUSIVE OF CM COMANDOS)


CM Comandos Lineares has developed an innovative and pioneering system in the world of parallelism between UPSs. Multi
Active Parallel System allows system expansion, according to your consumption demand and may parallel as many units needed
to meet your demand, increasing system capacity and its application reliability.

Input Mains

UPS 1 UPS 2 UPS 3 UPS 4 UPS 5 UPS 6


Power of 50 kVA Power of Power of Power of Power of Power of
100 kVA 20 kVA 30 kVA 80 kVA 120 kVA

Load Provided by the System = 400 kVA


Output

UNLIMITED PARALLELISM REDUNDANT PARALLEL CONNECTION


As many units can be parallel as needed, allowing system It allows parallel redundant connection N + 1, N + 2, N + 3 ... N + X,
expansion, according to consumption demand. allowing the disengagement of one or more units, keeping the active
load.
NO MASTER OR SLAVE UPS
POSSIBILITY OF POWER SUMMATION
All UPSs are autonomous, operate independently in the system
It allows connection to power summation, using two or more UPSs to
and have individual control. meet the demand of full load. When used for power summation, it
COMMUNICATION BETWEEN UPS allows the connection of UPSs with different powers. When the
Communication between UPS is the common communication connection is made with UPS of different powers, the load will be
bus, where information goes by, including charge level, timing distributed proportionately.
and status of the bypass.
UPS MAINTENANCE
BATTERY BANK PARALLELISM
It allows insertion and removal of UPS from the system without the
Allows battery bank paralleling (when they are of the same
nominal voltage). need to stop.
TECHNICAL DATA
n Technology
Measurement Physical and Mechanical Features
• On line - Double Conversion
nTrue RMS nCompact dimensions
Input nOutput power in kVA nTFT 4.3" Touch Screen
n Voltage: Output power in kW
n
nCabinet structure:
• Three Phase: 208 / 220 / 380 / 400 / 440V nOutput Power Factor • Rack: metal
n Allowance variance: nOutput Voltage
• Removable side and top covers
•± 15% of nominal voltage nOutput Current
• Finish: epoxy powder painting in graphite color
n Frequency: 50 or 60 Hz nOutput Frequency
with thermal and anticorrosive treatment
n Variation of Allowable Frequency: ± 8% nBattery voltage
Battery current * nVentilation: forced, with digital speed control by
n Settingon: n
DSP
nInput Power Factor*
• Three Phase: 3F + N + T nIsolation Transformer: electrostatics Shielded
nInput voltage
n Power Factor: Communication port:
nInput Current * n

• 0,8 • Serial RS232C Isolated Full Duplex -DB9 Female*


nInput Frequency
• 0,99* • Dry Contact DB9 Female
Output
Alarms Management Interfaces
nVoltage:
nControlled by the DSP processor
• 208 / 220 / 380 / 400 / 440V nSingle and multi-user, client-server, multi-server
nTypes of Alarms:
nAvailable Power: nMultiple servers on a single UPS
•Sound:
• 5/10/15/20/30/40/60/80/100/120/160/200 kVA nShutdown and Management Tools
» Network Missing: 1 ring each 4 sec
nStatic Regulation: ± 1% nominal » Pre-alarm of Batteries: 1 ring per second nProtocols:
nFrequency: 50 or 60 Hz » Internal UPS Failure: continuous alarm •Serial Rs232
nFrequency Variance: • Alert Messages: • Serial Rs485*
• ± 0,05% in battery mode » LCD • SNMP / Telnet / http / TCP/IP*
nSetting: » Software UPSMON, local or remote nManagement software *
• Three Phase: 3F +N + T » Message by e-mail, cell phone or pop-up: •UPSMAN / UPSMON / RCCMD
nPower Factor: 0,8 - Normal Operation • ASNMP CS121BL Adapter
nWaveform: sine - Network Failure • UNMS II
nHarmonic Distortion THD: less than 1%, total - Pre-alarm of Batteries nEnvironments and operating systems
nPeak Factor: 3:1 - Active Static Bypass •Windows 8 / 10 / 2010
Overload Capacity: 125% for25s - Active Manual Bypass
n • Linux*
- Output Overload (Brands of reuse manufacturers)
nEfficiency: 90%
- Fail * Optional

Batteries
nLine Voltage: Event Log
• 288VDC (5 to 30 kVA nStored Records:
• 384VDC (40 to 80 kVA) •Memory with 25,500 records (15 configuration logs Models with internal batteries
• 480 VDC (100 to 200 kVA) and 495 event logs)

We encourage recycling
Model Power Physical Dimension Weight
Recharge System: controlled, automatic •Indications of Date, time and occurrence hxwxd
n kVA (with
• Measurements mm batteries)
nRecharge Time:
• Operation Status and Panel Alarms Kg
• 8 to 10 hours for 90% of load 5000 5,0 900 X 480X 980 295
•Status of Internal Switches
nType: sealed, maintenance-free 10000 10,0 900 X 480 X 980 305
nAutonomy of NVRAM:
• 5 years (with UPS off ) 15000 15,0 900 X 480 X 980 409
Static Bypass
20000 20,0 1180 X 550 X 980 560

CM.MKT MAR 22 - Specifications are subject to change without previous notice.


nAction: automatic, DSP controlled
nTransfer Time: 0ms (null) Operating Features 30000 30,0 1180 X 550 X 980 640
nRetransfer to Normal Mode: automatic nAudible Noise: 55 dBA to 60 dBA at 1 meter Models with no battery
nMTBF (Mean Time Between Failures): 200,000 hours Physical Dimension Weight
Model Power
Maintenance Static Bypass nMTTR (Mean Time To Repair): 30 minutes kVA hxwxd (with
nAllows UPS Maintenance without disconnecting the nAmbient Temperature: mm batteries)
load •UPS: 20ºC to 40ºC 40000 40,0 1355 X 720 X 940 490
nAction: manual, through Circuit Breaker • Batteries: 0ºC to 30ºC
60000 60,0 1355 X 720 X 940 560
nChange to Normal Mode: without interruption • Recommended: 20ºC and 25ºC
nRelative Humidity: 80000 80,0 1900 X 780 X 920 730
Electrical Protections • 0% to 95% non-condensing 100000 100,0 1900 X 785 X 925 870
n Input and Output Undervoltage and Overvoltage • Recommended: 45% to 55%
n DC Undervoltage and Overvoltage and Battery nAltitude: up to 1,000m 120000 120,0 1900 X 785 X 925 1000
n Overload and Short Circuit nRecommended Environment Type: 160000 160,0 1900 X 1265 X 1000 1200
n Minimum Battery Discharge • Intern, indoor installation
•Atmosphere: clean, free from conductive particles, 200000 200,0 1900 X 1265 X 1000 1300
n Over temperature
toxic, flammable liquids and gases.
300000 300,0 2010 X 2050 X 1000 2280
nDegree of Protection: IP-20

DOS L
AN I
M
NN E

ISO
E AA R
C M C OO

ISO
ES

9001
9001
2015
2008
QUALIT Y

Av. Eng. Alberto de Zagottis, 760 - 04675-085 - São Paulo - SP - Brazil


Sistema de
Phone.: (+55 - 11) 5696-5000
Sustentabilidade Auditada
www.cmcomandos.com.br

You might also like