You are on page 1of 8

Ethiopian Electric Power

Transmission Substation Operation

Substation Profile data

Gelan Substation
Ethiopian Electric Power
Transmission Substation Operation

Substation Profile data

I. Substation General Information


Substation Name Gelan
Region Name Central II
Region Director Name and Mobile Number Alemayew Zeberga 0918767555
Substation In charge Name Meseret
Substation In charge Mobile Number 0918819529
Substation Specific location
Number of Employees
Substation in service Year

II. Substation Data


1. Transformer capacity and loading data

Transformer Loading
S.N Voltage Level (KV) Capacity (MVA)
Primary (MW) Secondary Tertiary (MW)
(MW)
3*400/230kv 500 310 313
3*230/132kv 125/125/40 88 81
132/15kv 50 29 31
132/15kv 50 14.1 14.1
2*132/33kv 50 0 0

2. HV Incoming and Outgoing Transmission Line Data and Loading (>132KV)


S.N Transmission Line Name Type of TL Conductor Cross TL Loading (MW)
section (mm2)
1 Sebeta 2- Gelan (400kv) Single 851 78.12
2 Holeta-Gelan(400kv) double 851 L1=58.3, L2=53.6
3 Wolayta Sodo-Gelan(400kv) Single circuit on L1=221, L2=217.8
double tower 851

4 Gelan-Kaliti I (230kv) Double L1=85, L2=86.9


450
5 Gelan- Kality I(132kv) Double L1=11.2, L2=30
166
6 Gelan-Yesu(132kv) Double 16.39
166
7 Gelan-Debrezeit II (400kv) single L1=15.8,L2(C13=15.8
180
,C15=6.8,C16=7.2)
8 Koka-Gelan(230kv) Double 450 L1=91.4, L2=57.3
Ethiopian Electric Power
Transmission Substation Operation

Substation Profile data

9 Koka- Gelan Mojo Mobile single


166
Tap(132)
10 Koka- Kanoria single 167 2.49
11 KOKA-D.Z single 166 44.6
12 KOKA-ILG single 166 30.2

3. Transformer feeders data (33KV or/ and 15KV side)

S.N Transformer Feeder Name CT Ratio Cable Size Protection Loading


(mm2) Setting (MW)

2.

4. Outgoing Lines number and loading data (33KV or /and15KV )

S.N Outgoing Line Name CT Ratio Cable Size Protection Loading (A)
(mm2) Setting
15kv L-1 (K3)
600/1 400 248

15kv L-2 (K4)


600/1 400 75

15kv L-3 (K6)


600/1 400 364

15kv L-4 (K7)


600/1 400 566

15kv L-5 (K8)


600/1 400 266

15kv L-6 (K9)


600/1 400 168

15kv L-7 (K21) 400


800/1 167
Ethiopian Electric Power
Transmission Substation Operation

Substation Profile data

15kv L-8 (K15) 400


800/1 330
15kv L-9 (K16) 400
800/1 272

III. Substation Equipment’s Type and Manufacturers


1. Auto/Power Transformer
Name of
S.N Equipment Name Voltage Level Status/Operating/Defective/Old
Manufacturers
3*Auto Trafo 400/230kV china

3* Auto Trafo 230/132kV china

Power Trafo 132/15kV 132/15kv china

2. Circuit Breaker

Voltage Level Name of Status/Operating/Defective/Old


S.N Equipment Name
Manufacturers

1 Sebeta II 400kV Line ABB Sweeden

2 SODO 2*400kV( line 1& 2) “

3 Holeta (Not energized) 2*400kV ( line 1& 2) “

4 Kaliti 1 230kV( Line 1&2) “

5 Koka 230kV (Line 1&2) “

6 Kaliti 1 132kV Line 2 “

7 Koka 132kV Line “

8 Koka-Illalageda 132kV Line “

9 Koka-Debrezeit 132kV Line “


Ethiopian Electric Power
Transmission Substation Operation

Substation Profile data

10 Yesu 132kV Line “

11 3*AutoTrafo CB 400/230kV 400kV “


Side
12 “
3*AutoTrafo CB 400/230kV 230kV Side

13 3*AutoTrafo CB 230/132KV 230KV side “

14 3*AutoTrafo CB 230/132KV 132KV side “

15 Power Trafo 132/15kV “

3. HV Current Transformer

Voltage Level Name of Status/


S.N Equipment Name
Manufacturers CT Ratio Operating/
Defective/Old
1 Sebeta II 400kV Line arteche 1600/1A

2 SODO 2*400kV( line 1& “ 1600/1A


2)

3 Holeta (Not energized) 2*400kV ( line 1& “ 1000-2000/1A


2)

4 Kaliti 1 230kV( Line 1&2) “ 1600/1A

5 Koka 230kV (Line 1&2) “ 1600/1A

6 Kaliti 1 132kV Line 2 “ 800/1A

7 Koka 132kV Line “ 800/1A

8 Koka-Illalageda 132kV Line “ 800/1A


Ethiopian Electric Power
Transmission Substation Operation

Substation Profile data

9 Koka-Debrezeit 132kV Line “ 800/1A

10 Yesu 132kV Line “ 800/1A

11 3*AutoTrafo CT 400/230kV 400kV “ 1600/1A


Side
12 400/230kV 230kV “ 1600/1A
3*AutoTrafo CT
Side
13 3*AutoTrafo CT 230/132KV 230KV “
side 800/1A
14 3*AutoTrafo CT 230/132KV 132KV “
side 800/1A
15 Power Trafo CT 132/15kV “
800/1A

4. Earthing Transformer
Name of
S.N Equipment Name Voltage Level Status/Operating/Defective/Old
Manufacturers
Power Transformer 1
15KV TBEA

5. Disconnector
Name of
S.N Equipment Name Voltage Level Status/Operating/Defective/Old
Manufacturers
Ethiopian Electric Power
Transmission Substation Operation

Substation Profile data

6. Voltage Transformer

Voltage Level Name of Status/


S.N Equipment Name
Manufacturers CT Ratio Operating/
Defective/Old
1 Sebeta II 400kV Line

2 SODO 2*400kV( line 1&


2)

3 Holeta (Not energized) 2*400kV ( line 1&


2)
4 Kaliti 1 230kV( Line 1&2)

5 Koka 230kV (Line 1&2)

6 Kaliti 1 132kV Line 2

7 Koka 132kV Line NISSIN ELECTRIC


CHINA

8 Koka-Illalageda 132kV Line “

9 Koka-Debrezeit 132kV Line “

10 Yesu 132kV Line “

11 3*AutoTrafo CT 400/230kV 400kV “


Side
12 400/230kV 230kV “
3*AutoTrafo CT
Side
13 3*AutoTrafo CT 230/132KV 230KV “
side
14 3*AutoTrafo CT 230/132KV 132KV “
side
15 Power Trafo CT 132/15kV “

Busbar A & B “
2* 230kV
Ethiopian Electric Power
Transmission Substation Operation

Substation Profile data

Busbar A & B
2*132KV “

IV. Single line diagram

V. Google Map and GPS Location

VI. Upgrading and rehabilitation

VII. Substation Extension Space Availability