Professional Documents
Culture Documents
MODEL NAME DIA ’D’ H.O. S PPE NB PIPE NB SHELL DISH MOC PIPE NB PIPE NB SHELL DISH MOC
DIMENSIO NS ARE IN
MOC. The Ru bber Linin g of thic k ness 3 mm VERSAOC U NIT DETAI L: — VERSAIRF13 2000 2000 100 40 6 8 MS
PIPE NB PIPE NB SHELL DISH MOC VERSAIRF14 2100 2000 100 40 6 8 MS
INTERESTS WITHOUT
wilI be pro vided to vess el. MODEL NAME DIA ‘D’ H.0.S
'D1 'D2’ THK.mm THK.mm VERSAIRF15 2200 2000 125 40 6 8 MS
VERSA0C01 800 1500 65 20 4 5 MS VERSAIRF16 2300 2000 125 40 6 10 MS
VERSA0C02 900 1500 80 20 4 5 MS VERSAIRF17 2400 2000 125 50 6 10 MS
THIS DRAWING lS THE PROPERTY OF THERMAX
APPD. BY A R
CO NSU LTANT: — TITLE: — P& I DIAGRAM FOR
VERSA FILTERS
CHKD. BY US P
THERMAX LIMITED (DM F/ACF/IRF/OC)
00 14.03.18 ISSUED FOR INFORMATIO N ABJ US P AR DRAWN BY ABJ WATER A WASTE SOLUTIONS
REV. DRAWN CHKD. APPD. ENVIRONMENT HOUSE, O.C.NO. DRG.
NO. SHEET NO. REV. NO.
LIMITED
MODEL NAME DIA ’D’ H.O. S PPE NB PIPE NB SHELL DISH MOC MODEL NAME DIA ‘D’ H.0.S PIPE NB PIPE NB SHELL DISH MOC
DIMENSIO NS ARE IN
MOC. The Ru bber Linin g of thic k ness 3 mm VERSAOC U NIT DETAI L: — VERSAIRF13 2000 2000 100 40 6 8 MS
PIPE NB PIPE NB SHELL DISH MOC VERSAIRF14 2100 2000 100 40 6 8 MS
INTERESTS WITHOUT
wilI be pro vided to vess el. MODEL NAME DIA ‘D’ H.0.S
'D1 'D2’ THK.mm THK.mm VERSAIRF15 2200 2000 125 40 6 8 MS
VERSA0C01 800 1500 65 20 4 5 MS VERSAIRF16 2300 2000 125 40 6 10 MS
VERSA0C02 900 1500 80 20 4 5 MS VERSAIRF17 2400 2000 125 50 6 10 MS
THIS DRAWING lS THE PROPERTY OF THERMAX
APPD. BY A R
CO NSU LTANT: — TITLE: — P& I DIAGRAM FOR
VERSA FILTERS
CHKD. BY US P
THERMAX LIMITED (DM F/ACF/IRF/OC)
00 14.03.18 ISSUED FOR INFORMATIO N ABJ US P AR DRAWN BY ABJ WATER A WASTE SOLUTIONS
REV. DRAWN CHKD. APPD. ENVIRONMENT HOUSE, O.C.NO. DRG.
NO. SHEET NO. REV. NO.
LIMITED
Contents
1. Process design basis
3. Scope of Works
4. Termination Points
5. Make of components
1. Process Design Basis
This treatment scheme has been designed to treat the water having following characteristics-
A) Inlet Parameters:
B) Outlet Parameters:
C) Plant Details:
Self-Cleaning Filter
Anti-Scalant Dosing
Cartridge Filter
RO Osmosis Unit
Drain
4
3. Scope of Works
I. Mechanical
II. Instruments
Sr. no Item Qty Location
1 Pressure Indicator 4 nos. Feed pump discharge, Inlet of pressure tube,
Reject, Outlet of cartridge filter
2 Pressure Switch 1 no. Inlet of HPP
3 Flow Sensor 3 nos. Recirculation, Reject & Permeate line
4 Level Switch 1 no. Treated water tank
5 Conductivity Sensor 1 no. Permeate of RO
III. Electrical
Electrical list
Cables
o Flexible Copper conductor Power, control & instrumentation cabling as per IS-
1554 are considered with PVC Cable glands and lugs for end termination.
Starter Panel
o Microprocessor based starter panel; MS powder coated.
5
4. Termination Points
6
5. Make of Components
Sr. Description Make
No
1 Filter Feed Pump
2 Self-Cleaning Filter
3 Cartridge Filter Housing and Cartridge
4 High Pressure Pump
5 Pressure Tube
6 Membrane
7 ICPW All the makes for bought out component use in
8 Pressure Indicator offered RO plant are selected in line with process
9 Pressure Switch requirement.
10 Flow Sensor
11 Level Switch
12 Conductivity Meter
13 Astro Panel
14 Cable
7
2 5 6 7 8
RNG.
DRA]
ASTRO PANEL •• ••
A
PI ” CI
s
DIMENSONS
25 NB
scr 25 NB UPVC 32 NE 5 NI
DOUBT
FS
UPVC UPVC PVC 25
RAW WATER uPvc i
NOT
BY CLIENTS V26 i
IN 25 NB B
V27 uPvc
V50 — — —
RAW WATER
TANK TO DRAIN •
BY CLIENT V25
ANTISCALENT DOS NG
40 NB TANK FS STORAGE TANK
UPVC BY CUENT —
A STM
TO DRAIN
EXHIBITED IN ANY WAY DETREMENTAL TO OUR INTERESTS WITHOUT OUR WRITTEN CONSENT.
ANTISCALENT DOSING TANK TAS CAP.:— 50 LTRS. 1 THERMAX LS LEVEL SWITCHES 1 THERklAX
E E
WITH LEVEL SWITCH CI CONDUCTIVITY kIETER 1 THERkIAX
5 CARTRIDGE FILTER CF1 4.0M3/HR e 5 MICRONS 1 PP ASTRO 13 PANEL 1 THERMAX APPD.
6 HIGH PRESSURE PUMP SS30 HPP 6 8 HR 13 6 KG C 2 1 THERMAX
7 PRESSURE TUBES (300 PSI) PT SUITABLE FOR 1 ELEMENT 2 THERMAX APPD. PLANT DETAILS: —
8 MEMBRANES ME 8"—400 SQ FT 2 THERI\FAX
UNIT TREATMENT
kIARK FLOWS
F F
OUR TERMINATION POINTS:— INLET WATER:— NOS /HR
VALVE LEGEND SIZE FLOW PRESSURE CONN.STD. TDS : 1500 ppm CF1 INLET 4.0
DIAPHRAGM VALVE BALL VALYE
uAR DESCRIPTION NB |g3 /HR Kgs/cm2
PERMEATE 2.0
BUWERFLY VALVE q@$g y yg
A F-F-P SUCTION 40 4.0 FLOODED SOCKETED UTLET WATER
CHECK VALVE NEEDLE VALVE MTE VALVE REJECT 2.0
SOLENOID VALVE B REJECT 2.0 ATM. SOCKETED TDS 100 ppm
——————— SCOPE OF CMENT RREECCIIRRCCUU 2.8
C PERMEATE 25 2.0 ATMS SOCKETED
^^ ^^ ELECTRICAL INTERLOCK LATION
RECOVERY 50%
cAD riLE NO. CODE NO . CLIENT:— —
PROJECT:— E SERIES RO PLANT
02 11.08.21 REVISED AS MARKED ABJ PB J’ CONSULTANT:—
TITLE:—
01 29.06.21 REVISED AS MARKED
APPD. BY JM P&I DIAGRAM FOR
H ABJ PB JM
CHKD. BY PB THERMAX LIMITED E-2000LPH
00 22.06.21 ISSUED FOR INFORMATION ABJ PB Jkl WATER d‹ WASTE SOLUTIONS
REV. DRAWN CHKD. APPD.
DRAWN BY ABJ ENVIRONMENT HOUSE,
0.C.NO. DRG.NO. SHEET NO. REV.NO.
PLOT NO. 90-92, BG BLOCK,
DATE DESCRIPTION
NO. DATE 22.06.21 SCALE BTS N.I.D.C BHOSARI, PUNE—411026.(INDIA) THERMAX E-2000LPH E2000LPHW3B1 1 OF 1 02
2 5
6 7 8
8
SMART DOSING SYSTEM
Free Standing Unit with Top Mounted Dosing Pump
Features :
• Optimized chemical consumption
• MOC : FRP/LLDP
• Minimum maintenance