You are on page 1of 2

CMM4 QUICK START GUIDE

See Details A & B


DETAIL A
Cable Housings
POLE BRACKET FRONT 1

Cabling Diagram on Cable Gland


Inside of Front Door
SEE SHEET 2
Connector

DETAIL B
3 Cables Fed Through Cable Gland
2X Grounding Lockable
POLE BRACKET REAR Lugs and Terminals Hinged Cover

Note:

Ensure mounting position is: ETHERNET


J2
TRANS PROTECT

GROUND
ETHERNET
J1

• not farther then 328 feet (100M) from the


furthest AP or BH that the CMM4 will serve. + _ _ +
• is not closer than 10 feet (3m) to the nearest AP
or BH.
• is not further than 100 feet (30.5m) of cable
from the intended mounting position of the
antenna gps.
• allows the doors to open fully for service.

2X 2X Cable
RJ45 Jacks Grommets 200SSD SUPPRESSOR 600SSD SUPPRESSOR
Used with Gigabit Ports All wires must exit
L-COM (optional) Optional if Gigabit Ethernet iis used through the allocated slots
Used with
Gigabit Ethernet Connection

2 Wire Gauge for 56 VDC Power Supply:

• Up to 90 ft (3-25m) 12 AWG (4 mm2)


• 91 -145 ft (26-45m) 10 AWG (6 mm2)
• 146-230 ft (46-70m) 8 AWG (10 mm2)

IN N L
convert

Input

Output
power -one-
AUX 2
AUX 1

+ + - - + + - -

select
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3

OUT Output

+ + - - + + - -
AUX 2
AUX 1

N L
Input
56 VDC Pwr DC CMM4 VDC POWER SUPPLY 56 VDC Pwr Supply Per AC
Black Red
TOTAL 20 VDC Green
ACCESSORY POWER Twist wire pair 1 twist per inch and
IS NOT TO EXCEED

GND
PWR
form three loops around ferrite core
20 WATTS. for RF emission compliance.
EtherWAN Switch
Short wire to ChassisGround ( Power Port View )
ACCESSORY POWER
OUTPUTS at Switch mounting screw
NOTE:
for RF emission compliance. Refer to the System User Guide for
+20 V +20 V the power requirement of the switch
OUTPUT OUTPUT
specific to the switch part number.
GND (Black) REDUNDANT REDUNDANT
+V (Red) +29 V +29 V +56 V +56 V
INPUT INPUT INPUT INPUT
GND GND +V GND GND +V
+V GND +V GND +V GND +V GND PE

EXTERNAL
PROTECTIVE EARTH
GROUND
CMM4 CONTROLLER ( Power Port View )

+29 V +56 V
EtherWAN Switch
OUTPUT OUTPUT ( Ethernet Port View )
Red Green
RS232

1 3 5 7 9 11
ETHERNET PWR

OR
2 4 6 8 10 12 13 14
DEFAULT

ACTIVITY

SYNC OK
POWER

GPS_M

Red Green
1000 BaseT 1000 BaseT
LINK

+29 V +56 V
DEFAULT OUTPUT OUTPUT (Gigabit Ethernet Ports)
NORMAL

TOGGLE SHIELDED ETHERNET CABLES


GPS SWITCH
AUX SYNC ETHERNET 2 4 6 8 2 4 6 8
RECEIVER
1 3 5 7 1 3 5 7
LEDs
INTERNAL CMM4 CONTROLLER ( Ethernet Port View )
GPS CABLE
N Connector
TO GPS ANTENNA

CMM4 CABLING DIAGRAM

• GPS coax cable must be


GPS Tools:
less than 30m (100 feet).
• Electrical tape
• Water tight tape
GPS Antenna • Orient the GPS antenna so
• 3/8 inch nut driver
it has clear access to the
• 7/16 inch wrench
southern horizon, up to 20
• Needle nose pliers
degrees.
• Use water tight tape
and electrical tape to
• Do not install the GPS as
seal the connector. 2X Nut
Manufacture the highest object at the site.
Pole 2X Lock Washer
Cable Mounting Bracket

GPS ANTENNA MOUNTED TO POLE

CMM4 Quick Installation - Revision 2


MAY 2010

You might also like