Magnetostrictive, Absolute, Non-contact SENSORS
Linear-Position Sensors
The High Pressure Housing (HPH) is ATEX EEx approved or UL and cUL
approved for use in hazardous locations with a range of Temposonics
linear-position sensors
All specifications are subject to change. Contact MTS for specifications and engineering
drawings that are critical to your application. Drawings contained in this document are for
reference only. Go to http://summitusa-LLC.com for the latest support documentation and
related media.
Product Overview and Specifications Product Data Sheet
Zone 1
86 mm
147 - 198 mm
19.5 mm
M18 or
3/4 in. UNF 25 mm
M5
25 mm 69 mm dia.
Mounting Zone
51 mm Figure 2. Top mounted cable gland
M18 or Dimensions, side mounted cable gland
3/4 in.
64 mm
85 mm dia.
64 mm dia.
Measuring length
50 mm to 7500 mm
M18 or
Figure 1. HPH Sensor and housing dimension references
3/4 in. UNF 25 mm
56 mm dia.
69 mm dia.
Special order
Type Standard in quantities Standard Special order in quantities
TOP
M18
M18 3/4” UNF
3/4” UNF M18M18 3/4”3/4”
UNFUNF M18 M18 3/4” UNF
3/4” UNF
Approval ATEX only ATEX only UL and cUL ATEX only UL and cUL
M20
0100 0600
M20
0300 0800
2100 2200
The Rotation adapter accessory (see ‘Figure 4’) allows you to adjust
the position of the side opening when the HPH is mounted in a
cylinder. RTA-3/4 in. UNF-2 is for use with the 3/4" UNF housing
thread and has a 1 1/16 in. - #12 SAE Boss O-ring mounting thread.
Ordering Information
Use the form below to order a High Pressure Housing
Choose a design combination from the Design Combination Chart (4-7) = 4-7
Refer to ‘Table 1. HPH Design Combination Chart’.
Enter Measuring Length (8-11) = 8 - 11
Refer to ‘Figure 1. HPH Sensor and housing dimension references’.
Enter Version (12) = 12
A = Approved version
N = Non approved version