You are on page 1of 2

CHECK ONCE

COMPLETED

1) location HOT AIR 6in/153mm

p
place the
charger
- u
in a well
ventilated S ET
area
C K T
U I E E
Q SH
COOL AIR 6in/153mm

2) safety first
disconnect and lock-out all ac sources and dc battery voltages

dc source
ac source off and off and
or battery
disconnect locked LOCKED
disconnect
switch
switch

3) electrical connections
a) connect ac power to the charger
ac source ac volts Ac input
VOLTAGE and phase voltage

EVO
WARNING BATTERY CHARGER / RECTIFIER

This Unit Has Been Connected


For An Output Of
INPUT OUTPUT
Volts

Phase
V

Do Not Connect To
Other Voltage Without
Reconnecting Input
Transformer - See
Instruction Manual

battery charger
JC0011-00

tag on
warning tag data nameplate ac breaker
all these parameters must match !

b) connect the battery or dc bus

FACTORY PRESET BATTERY OR


VOLTAGES DC BUS
NOTICE At The Factory As Follows
DC Output Charging Voltages
Have Been Preset
At The Factory As Follows
Float Mode: Volts
Float Mode: Volts

Equalize Mode: Volts


Equalize Mode: Volts
These Voltages Are
Adjustable Please Consult
Operating Manual
These Voltages Are
Output Current Limit
Has Been Set At
DC Amps

JC0016-00
please check the operating instructions
provided with your battery
tag on dc breaker for proper charging voltages

4) starting the charger


recheck your wiring! if it is correct, follow the start sequence below
Turn TURN
ON ON

1 3
ac source
distribution
panel
Turn ac
breaker on
2 4 Turn dc
breaker on

5) setting THE parameters


adjustable parameters (in selection order):

1) float voltage 4) high dc voltage alarm


Float Eqlz Mthd: Man
2) equalize voltage 5) low dc voltage alarm
3) equalize timer hours 6) current limit 131.0 Amps
Volts

press the enter key once to begin the adjustment process.


5.0
the first value (float voltage) will be displayed. adjust
this value by pressing the up or down arrow keys. press
“enter” again to save and advance to the next parameter
For adjustment. repeat this process to adjust the rest of
The parameters listed above.

if no keys are pressed for 25 seconds, the charger will


return to normal operation.

For further instructions be sure to read the operating and


service instructions or visit online at ... atseries.net
d o n e !
JC5020-51
please check the operating instructions
provided with your battery
for proper charging voltages

5-1) SETTING THE - PRESS EDIT/ENTER KEY


FLOAT VOLTAGE LCD Screen WILL Display THE FLOAT VOLTAGE
see Manual
Float Voltage (V)

131.0
section 3.3 Menu Back Enter Accept
- PRESS THE ARROW KEYS
UP ARROW KEY WILL INCREASE
Float Voltage (V) DOWN ARROW WILL DECREASE
- PRESS EDIT/ENTER KEY
131.0 WILL SAVE YOUR CHANGES
AND GO TO THE NEXT PARAMETER
Menu Back Enter Accept

5-2) SETTING THE - PRESS EDIT/ENTER KEY


EQUALIZE VOLTAGE
LCD Screen WILL Display THE EQUALIZE VOLTAGE
see Manual Equalize Voltage (V)

139.0
section 3.3 Menu Back Enter Accept
- PRESS THE ARROW KEYS
UP ARROW KEY WILL INCREASE
Equalize Voltage (V) DOWN ARROW WILL DECREASE

139.0
- PRESS EDIT/ENTER KEY
WILL SAVE YOUR CHANGES
AND GO TO THE NEXT PARAMETER
Menu Back Enter Accept

5-3) SETTING THE


- PRESS EDIT/ENTER KEY
EQUALIZE
TIMER Equalize Time(hours) LCD Screen WILL Display THE EQUALIZE TIMER
24
see Manual Menu Back Enter Accept - PRESS THE ARROW KEYS
section 3.3 UP ARROW KEY WILL INCREASE
Equalize Time(hours) DOWN ARROW WILL DECREASE

24 - PRESS EDIT/ENTER KEY


WILL SAVE YOUR CHANGES
AND GO TO THE NEXT PARAMETER
Menu Back Enter Accept

5-4) SETTING THE


HIGH DC VOLTAGE - PRESS EDIT/ENTER KEY
ALARM High DC Alarm (V) LCD Screen WILL Display THE HIGH DC ALARM (V)
144.0
see Manual Menu Back Enter Accept - PRESS THE ARROW KEYS
section 3.3 UP ARROW KEY WILL INCREASE
High DC Alarm (V) DOWN ARROW WILL DECREASE

144.0 - PRESS EDIT/ENTER KEY


WILL SAVE YOUR CHANGES
AND GO TO THE NEXT PARAMETER
Menu Back Enter Accept

5-5) SETTING the


- PRESS EDIT/ENTER KEY
LOW DC VOLTAGE
ALARM Low DC Alarm (V)
LCD Screen WILL Display THE Low dc alarm (V)
see Manual 120.0
Menu Back Enter Accept
- PRESS THE ARROW KEYS
section 3.3 UP ARROW KEY WILL INCREASE
Low DC Alarm (V) DOWN ARROW WILL DECREASE

120.0 - PRESS EDIT/ENTER KEY


WILL SAVE YOUR CHANGES
AND GO TO THE NEXT PARAMETER
Menu Back Enter Accept

5-6) SETTING the


- PRESS EDIT/ENTER KEY
CURRENT LIMIT
see Manual Current Limit (A)
LCD Screen WILL Display THE Current limit
120.0
section 3.3 Menu Back Enter Accept - PRESS THE ARROW KEYS
UP ARROW KEY WILL INCREASE
Current Limit (A) DOWN ARROW WILL DECREASE

120.0 - PRESS EDIT/ENTER KEY


WILL SAVE YOUR CHANGES
AND GO TO THE NEXT PARAMETER
Menu Back Enter Accept

jc5020-51

You might also like