Design Data Indoors, mildly corrosive Marine, offshore, petrochemical,

Recommended Tensile Loads Nrec (kN) environment, or for limited caloric (coal oil) power plants etc
lifetime use
Dimensions
X-FCM-M X-FCM-R Grating
Grating opening type Duplex coated Item no. Stainless Steel Item no. L (mm) Height (mm)
Bar spacing (mm) Bar spacing (mm) X-FCM-M 25/30 378683 X-FCM-R 25/30 247181 23 25-30
18 30 18 30 X-FCM-M 1 1/4-1 1/2 378686 X-FCM-R 1 1/4-1 1/2 247184 30 32-38
X-FCM-M 0.8** 0.8** 1.8* 0.8** X-FCM-M 35/40 378684 X-FCM-R 35/40 247182 33 35-40
X-FCM-R 1.4** 1.0** 1.8* 1.0** X-FCM-M 45/50 378685 X-FCM-R 45/50 247183 43 45-50
*Loading is limited by recommended load for the threaded stud Note: Note:
** Loading is limited by plastic deformation of the X-FCM disk. Not for use in marine Not for use in automobile
atmosphere or in a heavily tunnels swimming pools or
• X-FCM-M and X-FCM-R resist shear by friction and are not polluted environment similar environments
suitable for explicit shear load designs , e.g. diaphragms.
charactersistics, shear loads of upto about 0.3kN will not result in Min grating height L+ 2
Depending on surface permanent deformation. Therefore, small Governing requirement:
unexpected shear loads can generally be accomodated without • Minimum 2 mm clearance between X-FCM and top of steel to allow for
damage deflections and over tightening.