Professional Documents
Culture Documents
Ild 205 T
Ild 205 T
www.vishay.com
Vishay Semiconductors
Optocoupler, Phototransistor Output, Dual Channel,
SOIC-8 Package
FEATURES
A1 8C
• Two channel coupler
C2 7E
• SOIC-8 surface mountable package
A3 6C
• Standard lead spacing of 0.05"
C4 5E
• Available only on tape and reel option
i179018-2
(conforms to EIA standard 481-2)
i179025
• Isolation test voltage, 4000 VRMS
DESCRIPTION • Compatible with dual wave, vapor phase and IR reflow
soldering
The ILD205T, ILD206T, ILD207T, ILD211T, and ILD213T are
optically coupled pairs with a gallium arsenide infrared LED • Material categorization: for definitions of compliance
and a silicon NPN phototransistor. Signal information, please see www.vishay.com/doc?99912
including a DC level, can be transmitted by the device while
maintaining a high degree of electrical isolation between AGENCY APPROVALS
input and output. The ILD205T, ILD206T, ILD207T, ILD211T, • UL1577, file no. E52744 system code Y
and ILD213T come in a standard SOIC-8 small outline • cUL - file no. E52744, equivalent to CSA bulletin 5A
package for surface mounting which makes it ideally suited
for high density applications with limited space. In addition
to eliminating through-holes requirements, this package
conforms to standards for surface mounted devices.
A specified minimum and maximum CTR allows a narrow
tolerance in the electrical design of the adjacent circuits. The
high BVCEO of 70 V gives a higher safety margin compared
to the industry standard of 30 V.
ORDERING INFORMATION
SIOC-8
I L D 2 # # T
PART NUMBER
6.1 mm
CTR (%)
AGENCY CERTIFIED/PACKAGE
10 mA
UL, cUL 40 to 80 63 to 125 100 to 200 20 100
SOIC-8 ILD205T ILD206T ILD207T ILD211T ILD213T
IF
IF IF +5V
0 0
I C = 2 mA; adjusted through tp t
IC
input amplitude 100 %
90 %
R G = 50 Ω
tp
= 0.01
T
t p = 50 µs 10 %
Channel I
0
Oscilloscope tr
R L = 1 MΩ td tf t
Channel II ts
C L = 20 pF t on t off
50 Ω 100 Ω tp Pulse duration ts Storage time
td Delay time tf Fall time
tr Rise time t off (= ts + tf) Turn-off time
95 10804 t on (= td + tr) Turn-on time 96 11698
IF I F = 10 mA +5V
0
IC
R G = 50 Ω
tp
= 0.01
T
t p = 50 µs
Channel I
Oscilloscope
R L ≥ 1 MΩ
Channel II
C L ≤ 20 pF
50 Ω 1 kΩ
95 10843
1.6
ICE0 - Leakage Current (nA) IF = 0 mA
1.5 1000
VF - Forward Voltage (V)
Tamb = 0 °C
1.4
Tamb = -55 °C
1.3 VCE = 40 V
1.2 10
VCE = 12 V
1.1
Tamb = 25 °C VCE = 24 V
1.0
Tamb = 50 °C
0.1
0.9 Tamb = 75 °C
0.8
Tamb = 100 °C
0.7 0.001
0.1 1 10 100 -60 -40 -20 0 20 40 60 80 100
IF - Forward Current (mA) Tamb - Ambient Temperature (°C)
Fig. 4 - Forward Voltage vs. Forward Current Fig. 6 - Leakage Current vs. Ambient Temperature
25 30
IC - Collector Current (mA)
IC - Collector Current (mA)
25
20 IF = 30 mA
IF = 25 mA
20
15
IF = 20 mA 15 IF = 10 mA
10 IF = 15 mA
10
IF = 5 mA
IF = 10 mA
5 5
IF = 1 mA IF = 2 mA
IF = 5 mA
0 0
0 2 4 6 8 10 0 0.1 0.2 0.3 0.4
22327 VCE - Collector Emitter Voltage (NS) (V) 22329 VCE - Collector Emitter Voltage (sat) (V)
Fig. 5 - Collector Current vs. Collector Emitter Voltage Fig. 7 - Collector Current vs. Collector Emitter Voltage (saturated)
(non-saturated)
1.2 1.2
NCTR - Normalized CTR (non-sat.)
0.6 IF = 1 mA 0.6
0.4 0.4
Tamb = 25 °C
0.2 0.2
Normalized to CTR value: Tamb = 75 °C
IF = 10 mA, VCE = 5 V, Tamb = 25 °C Tamb = 100 °C
0 0
-60 -40 -20 0 20 40 60 80 100 120
0.1 1 10 100
Tamb - Ambient Temperature (°C) IF - Forward Current (mA)
Fig. 8 - Normalized CTR (saturated) vs. Ambient Temperature Fig. 11 - Normalized CTR (saturated) vs. Forward Current
1.0 1000
VCE = 5 V, IF = 10 mA
NCTR - Normalized CTR (sat.)
1
0.2
Normalized to CTR value:
IF = 10 mA, VCE = 5 V, Tamb = 25 °C
0 0.1
-60 -40 -20 0 20 40 60 80 100 120 0 5 10 15 20
Tamb - Ambient Temperature (°C) 22336 RL - Load Resistance (kΩ)
Fig. 9 - Normalized CTR (non-saturated) vs. Ambient Temperature Fig. 12 - Switching Time vs. Load Resistance
1.2 400
Package Power Dissipation (mW)
Tamb = 0 °C
NCTR - Normalized CTR (NS)
350
1.0 Tamb = -55 °C Dual channel
Tamb = 25 °C 300
0.8
250
0.6 200
Tamb = 75 °C 150 Single channel
0.4 Tamb = 100 °C
100
0.2 Normalized to:
IF = 10 mA, VCE = 5 V, 50
Tamb = 25 °C
0 0
-55 -30 -5 20 45 70 95 120
0.1 1 10 100
IF - Forward Current (mA) Tamb - Ambient Temperature (°C)
Fig. 10 - Normalized CTR (non-saturated) vs. Forward Current Fig. 13 - Power Dissipation vs. Ambient Temperature
D205
V YWW Y 68
Note
• Tape and reel suffix (T) is not part of the package marking.
8.0 (0.315)
Fig. 14
0
0 50 100 150 200 250 300
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product
with the properties described in the product specification is suitable for use in a particular application. Parameters provided in
datasheets and / or specifications may vary in different applications and performance may vary over time. All operating
parameters, including typical parameters, must be validated for each customer application by the customer's technical experts.
Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited
to the warranty expressed therein.
Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and
for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of
any of the products, services or opinions of the corporation, organization or individual associated with the third-party website.
Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website
or for that of subsequent links.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.