Professional Documents
Culture Documents
PROJECT ARCHITECTS:
CLIENT:
JSW Steel Coated Products Limited. FIRST FLOOR PLAT 2A UJAGAR INFOTECH PARK
OPPOSITE DEONAR BUS DEPOT SUNDAR BAUG GOVANDI EAST,
MUMBAI,MAHARASHTRA - 400088, TEL NO: 022 6155 1111
MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
DRAWING DOCUMENTATION-1 7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
15
STORAGE BAY
Document Set Content: Abbreviated Document Numbering: Civil Site Plans TRANSFER CAR GAL STORAGE BAY
GALVALUME 2
· North arrow, plan title and drawing scale COLOUR COATING LINE 2
Sheet Numbers may be condensed to three character for small-scale projects. Sheet Sequence numbers
COLOUR COATING LINE 1
The set of documents conveys the essential quantities and qualities necessary to make start co-ordination of · Access roads, parking lots, walks, site lighting (if required) and other site improvements with dimensions
all services from structural to MEP. The Co-ordination of project will be guided and regulated by documents. may be indicated with a single digit provided there are no more than 9 sheets in each category. When RAMP
· Finish grading
V
Paint Storage
determined to be appropriate for the project, this format shall be used consistently for all sheet numbers in SOAK PIT
utility zone
Cover Sheet Revised drawing sheets to milestone document sets may be tracked utilizing the sheet title block “Issue
Date” list, or may include revision identification with the sheet number. NCS Guidelines for identifying Landscape Site Plans
PREFIX SUBJECT SERIES
supplemental drawing identification, such as revisions, is by adding “Sheet Sequence Modifiers” at the end of · North arrow, plan title and drawing scale
AL LAYOUT PLANS 1
the basic sheet number. An example to indicate revision number 1 is :A201-R1”. · Paving plans
A ELEVATIONS 2
· Planting plans
A SECTIONS 3
Discipline Identification: · Irrigations
· Street Furniture/Lighting (if required)
Basic Discipline identification shall be indicated with a single letter. Expanded Discipline Identification, · All details indicated and numbered to refer to the appropriate detail sheet
indicated with two letters, provides the option to subdivide documents initiated by each discipline.
· All appropriate notes
Discipline Identification letters for general practice projects are noted below. They are listed in the standard Landscape Details
Sheet Numbering:-
order for organization of general practice Document Sets. · All details related to paving, street furniture and landscape work
ECPL philosophy in arranging the various types of architectural drawings is to create a sequence in which the
document user is led in an orderly way from a broad scope to an increasingly narrow scope. In other words, The basic list of 2 character Expanded Discipline Identifications, is indicated in the reference document
we begin with large scale site information, move through building plans, elevations and sections at 1:100 attached to this Manual. Additional expanded two letters Ids may also be created to supplement the basic list, Architectural General Information
scales. The schedules, which contain the most narrowly specific information, are provided in the when required to meet project requirements. · Abbreviations
specification. · Material Identification
Drawing Categories: · Dimensioning
All drawings, with the exception of the 1:100 plans which are typically the starting point of the set, must be · Symbols and References
referenced from a preceding sheet. It should never be necessary to move backward in the set to find a Drawing categories are indicated with a single digit character, and organized from general to detailed
· Toilet Accessory Mounting Heights
referenced drawing. information and from small scale to larger scale views. Category numbers are ordered into groups
appropriate for general practice document standards for each discipline. All share the same category
· Building Code Requirements 31-05-2023 SS BS FIRST ISSUE
A-1110 Roof Level Plan A-1101 Site plan · All rooms named and numbered FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
A-1102 Basement · All doors numbered
Overview:- A-1103 Stilt Floor Plan · Enlarged plan areas indicated
A-1104 First Floor Plan
· Plan details and interior elevation symbols indicated STRUCTURAL CONSULTANTS:
tested examples of ECPL practice, familiarity to players in the AEC industry, and is coordinated with the NCS A-1106 Third Floor Plan MEP CONSULTANTS:
Radiant Consulting Engineers
(National CAD Standard) document numbering system. A-1107 Fourth Floor Plan
Architectural Reflected Ceiling Plans
A-1108 Fifth Floor Plan · North arrow, plan title and drawing scale (1:100 metric)
The Standards shall be the basis of sheet numbering for each phase of the work. The project Team Leader Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
shall determine the numbering format to meet project requirements and shall organize the document set A-1109 Terrace Level Plan · Structural grid with dimensions Koparkhairane, Navi Mumbai, Maharashtra-400701, TEL NO:022-27782040
PROJECT:
before the drawings are started. The basic sheet numbering is in simple, clear, and easy to read graphic A-1110 Roof Level Plan · Lighting arranged (and dimensioned if necessary)
format, without dashes or dots between characters. Flexibility is provided in format to meet requirements of · Other electrical and mechanical devices, i.e. smoke detectors, diffusers, etc. MR-JSW-KLM
varying project types and complexity. The format selected for each project shall be consistently applied to all · Ceiling materials indicated by work notes or screen patterns Admin Building at JSWSCPL Kalmeshwar Works
sheets in the document set. Examples of sheet numbering for various project types are attached to this SCHEMATIC DESIGN · Soffits (with dimensions if necessary)
Manual to illustrate how to apply the basic numbering system. CLIENT: JSW Steel Coated Products LTD.
· Light covers
The SD set must include all the drawings necessary to fully describe the scope of work. An incomplete set
ECPL CAD Standards indicate that CAD file-names shall be consistent with the sheet number. Ex.. Sheet " · Expansion joints
will require additional documentation in the form of Addenda issued before the bid opening. Addenda are a
A201 " file-name is " A201.dwg ". headache for all concerned in the bidding process and should be avoided if possible. If additional
· Ladders and roofs hatches A-10/1, MIDC Industrial Area, SH265, Kalmeshwar-441501
documentation is necessary after the general contract is signed, significant costs to the owner or architect · All non-standard ceiling heights (a standard height should be identified in the General notes box) Nagpur-Maharashtra (India) TEL NO:917118271401
PROJECT ARCHITECTS:
may result. In any case, it is apparent the final construction document set must be complete and accurate. · All rooms numbered (no names)
· Details symbols numbered and referenced to the appropriate details sheet
Basic Document Numbering : EDIFICE CONSULTANTS PVT. LTD.
FIRST FLOOR PLAT 2A UJAGAR INFOTECH PARK
The SD drawings must include all the drawings included in the DD set, plus all additional drawings necessary · Different dashed lines indicating the location of each value of fire rating OPPOSITE DEONAR BUS DEPOT SUNDAR BAUG GOVANDI EAST,
MUMBAI,MAHARASHTRA - 400088, TEL NO: 022 6155 1111
to clearly define the scope of work. They also include Technical Specification, which are bound in the Project · All appropriate notes including work note symbols, a Work Note box, and a General Note box. · MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
Consists of four characters, which effectively covers all sheets in general practice documents sets. Standard
Manual, consisting of one or more volumes. The drawings should include the following: PURPOSE OF RELEASE
Discipline Identification is indicated by a single letter for general practice projects, and Standard Drawing SCHEMATIC DESIGN
Categories are noted by a single digit. Sheet Sequence Numbers are indicated by two digits, in variable
Cover Sheet STAGE: SD
format to meet project requirements. Drawing No: Current
· The project name and issue date Issue DIRECTION:
Revision:
N
· identification as "For Construction" Or as "Bid Documents" Or as "DD" G-0001 R0
· An updated perspective rendering of the building
Start Date: Issue Date: Last saved Date:
01-Jan-23 28-07-2023 28-Jul-23
Index Sheet Project Code: MR-JSW-KLM
Category Numbering · A drawing list Bldng/Block: ADMIN. BUILDING
Sequence Numbering
· Drawing documentation sheet Drawing
title:
DRAWING DOCUMENTATION-1
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
DRAWING DOCUMENTATION-2 7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
15
STORAGE BAY
· Location and extent of different roofing assemblies (Assemblies can be described in Work Note box or Specifications or both) As with exterior elevation symbols, building section symbols should be placed in paper space on the first level floor If the answer to both questions is “yes”, the wall should be drawn. With a computer, it is easy to 'mirror' or modify an COLOUR COATING LINE 2
· Non-standard roof slopes (a standard slope should be identified in the General Notes box) plans. It is acceptable to “ bend” or offset the section “cut line” if doing so increases the usefulness of the section. Be elevation to address each situation. In general, our preference is to err on the side of drawing too many interior elevations COLOUR COATING LINE 1
· Ridges and valleys careful not to over-complicate the section drawing. It must be understood before it can be useful. Detail section rather than too few. RAMP
symbols are used in floor plans to indicate locations of partial building sections wall sections, or other vertical details.
V
Paint Storage
· Primary roof drains or scuppers with drainage to each clearly established How to Draw Interior Elevations SOAK PIT
utility zone
· Overflow roof drains or scuppers Plan Detail Symbols ROAD 15M WIDE
Plan details differ from enlarges plans in that the depict a smaller area in much greater detail. Plan details are only Most interior elevations are essentially rectangles. The top line represents the ceiling, the bottom the floor, and the ends
· Roof hatches with “swing” indicated
· Ladders and paves necessary when an unusual condition exists in plan which can be defined in no other way. Generally, we try to avoid the corner or edge of the wall. These should be heavy lines. All other lines in an interior elevation should be thinner. KEY PLAN
0.0
· Roof top equipment with means of support noted or referenced plan details because of their limited informative ness, and because they create a potential for conflicts with the base Interior elevations should not show construction that is in front of but not attached to the wall being elevated. NTS
plans. When plan details are necessary, we use a continuous line circle to delineate the area to be detailed. The circle
· All appropriate notes including work done symbols, a work note box, and a General Note box. Casework will be further clarified in the casework schedule.
can be elongated if necessary to enclose the detailed area.
· Indicate location and thickness of tapered insulation.
· Patterns in Floor Plans Only those vertical dimensions necessary to locate an opening, cabinet or other item not clarified elsewhere in the set
· Architectural Building/Wall Sections Patterns are used in floor plans to depict materials or special areas. For example, it is useful to differentiate masonry should be given. Few horizontal dimensions are necessary. Typical devices can be located using a general note or
Drawing titles and scale (1:50 metric) from standards stud wall assemblies in order to enhance the clarity of the plan drawing. For this purpose we use a user drawing of the standard mounting dimensions. Important atypical wall mounted equipment or devices should be located
Building structure and structural gridlines with dimensions defined 450 diagonal hatch patterns with 4” spacing to indicate the masonry. Stud walls are never patterned.
and dimensioned horizontally and vertically on the interior elevations.
· Floor and parapet heights Some hatch patterns are extremely memory intensive and should be avoided. For example, the pre-defined patterns
· Expansion joints (if necessary) called AR-SAND and AR-CONC will greatly increase regeneration time and should be avoided. Double hatch patterns Devices specified by other trades, such as return air grills and alarm devices, should be identified. In the note, we should
· All important details indicated and numbered to refer to the appropriate detail sheet for tile should be used sparingly for the same reasons. only provide the generic name of the device. The specifics will be provided in the pertinent consultant documents.
· Larger rooms identified by name and number REFLECTED CEILING PLANS
· All appropriate notes Devices which we specify, such as toilet accessories and fire extinguisher cabinets, should be identified. If a paper towel
Reflected ceiling plans are included in the “A12” series. They are used to depict ceiling finishes, ceiling heights above
· finish floors, patterns, soffits and to locate ceiling mounted mechanical and electrical devices. In addition, we use ceiling dispenser is identified in the drawing as an ITEM4 (toilet accessory 4), it must also be identified in the specifications as ITEM4.
· Architectural Exterior Elevations plans to delineate the path of rated wall assemblies. A legend must be included in the drawing, in paper space, which As with all other drawing types, we arrange interior elevation sheets from left to right and from top to bottom.
Drawing titles and scale (1:100 metric) clarifies the meaning of the various line types which designate the different wall types. The legend should also define Interior elevations are typically drawn at a scale of ¼” = 1'-0”.
Structural gridlines (no dimensions) the other symbols, i.e. lights, speakers, diffusers, etc., used in the drawings. A General Note box should identify typical
· Materials identified by note or screen patterns materials or assemblies Work notes should identify atypical materials, conditions and assemblies. Do not repeat detail VERTICAL CIRCULATION
· All openings properly located and sized (no dimensions) or elevation references which appear on other drawing types. Vertical circulation drawings are included within the “A5” series of drawings. They are used to further define stairs,
· Header, bottom-of-lintel and top-of-wall elevations Partitions and structural grid information should appear in ceiling plans as they do in floor plans. Doors, casework and escalators and elevators. You should conceive of these drawings as virtually 'stand alone' drawings which can be
· Window and louver symbols other obvious items should not appear. delivered to suppliers and fabricators without other drawings. It should be possible for them to learn all they need to know
· Door and window swings
· Exterior lighting, bells, alarms and other devices with dimensions and notes ROOF PLANS about dimensions, floor heights, enclosures and structure to design and bid the work.
· Scuppers with dimensions and notes The roof plans complete the “A1” series of drawings. Use them to locate roof drains, slopes and scuppers, hips & Both enlarged plan drawings and sections at ¼” scale are required. Ideally, they will be arranged on the sheet so that their
· Control joints and expansion joints (if necessary) valleys, pavers, ladders, roof hatches, window washing davits & rooftop equipment. Dimensions should be provided to relationship is intuitively understood. In other words, the plan gridlines should align with the section gridlines. This may
· Finish Grade adjacent to building elevation locate any items whose location is critical. Structural grid information should appear on a roof plan as it does on floor
not always be practical, however. Frequently, enlarged vertical circulation floor plans are contained within other enlarged
· All appropriate notes plans. A General Note box should identify typical materials or assemblies. It should also contain any other general
notes necessary to clarify the drawings. Worknotes should identify atypical materials, conditions and assemblies. vertical circulation floor plans are contained within other enlarged floor plans. In such cases, the vertical circulation
·
· Architectural Enlarges Floor Plans Do not repeat details or elevation references which appear on other drawing types - building section and exterior sections can be referenced from the enlarged plans, but presented in the vertical circulation drawings.
Drawing title and scale (1:50 metric) elevation symbols already appear on the first floor plan, parapet heights appear on the building sections. It's okay if the Plan drawings, or multiple plans if necessary, should include fundamental dimensional information. For example, floor
Dimensioned stalls and stall doors roof plan looks comparatively Spartan.
openings should be sized and located relative to a gridline. Tread width and depth should be dimensioned. The edges of
· Dimensioned centerlines of plumbing fixtures The edge of the roof, or outer face of the parapets, should be drawn with a heavier line. The internal items, such as hips
· Grab bars floor slabs should be clearly indicated from the section.
and valleys or pavers, should be drawn with various thinner lines. Screen' patterns may be used to indicate special roof 31-05-2023 SS BS FIRST ISSUE
·
·
Room name and number
All appropriate notes
areas or assemblies. Do not use memory intensive patterns such as AR-SAND.
Indicate the location and thickness of tapered insulation.
DETAILS DATE
DRAWN
BY
CHECKED
BY
DESCRIPTION OF
THE REVISIONS
· The ways in which materials and components are assembled are the subject of detail drawings included in the “A8” and “A9” series. REVISIONS
A list of all drawings included in the set An exterior elevation drawing should include the following: Off DUKES FACTORY ROAD, CHEMBUR, MUMBAI - 71
Tel.:- 2520 7678 E-mail :- amsconsultants@gmail.com
An explanation of the symbols and abbreviations used in the document set. · The structural grid with gridlines identified but not dimensioned FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
· Space permitting a Site Vicinity Plan showing main access roads to the building site and a North arrow. · Exterior finish material indicated by notes
· Development of the project index is a clerical task more than an architectural one. Nonetheless, as the guide to the · Control joints and expansion joints if any
· drawing set, it must be complete and accurate. · A heavy ground line indicating grade at the building STRUCTURAL CONSULTANTS:
· Masonry ledges located above and below grade. Provide lengths and elevations of ledges MR. GIRISH WADHWA
· Any detail symbols not depicted elsewhere in the document set
FLOOR PLANS · Any notes necessary for clarity
CONSULTING STRUCTURAL ENGINEERS,
2nd Floor, Krushnakunj,3838-403, Opp Jain Derasar, RSC-26-27,Gorai 2, Borivali
West, Mumbai 400092, Ph: =91 9821216010, Email: gIrish@gtwcse.in
Floors plans, which are included in the “A1” series of drawings, are the heart of any set of construction drawings.They typically take · Outline of foundation system and indicate floor elevations The columns are named after their grids, if the column is on grid A-horizontal and on 02 grid vertically its name is A2 MEP CONSULTANTS:
Radiant Consulting Engineers
the most time to produce, but also contain more critical information than any other type of drawing. Plansshould be drawn as There are other items which should not be included. For Example, do not draw the foundation system. It is well defined in
if they are horizontal sections cut through the building at 4'-0” above the floor. Construction items higher than 4'-0” should be dashed.
the structural drawings and, if necessary, in the building sections. As always, avoid repeating information which is 01 02
Standards specific to floor plans are discussed below.
provided elsewhere in the set. Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
Grid Lines Koparkhairane, Navi Mumbai, Maharashtra-400701, TEL NO:022-27782040
INTERIOR ELEVATIONS
Vertical gridlines should be numbered alphabetically left to right. Horizontal gridlines should be letterednumerically from A PROJECT:
top to bottom. Gridline bubbles should be located along the top and right edges of the drawing. Interior elevations comprise the “A4” series of drawings. They are used to locate wall devices, clarify casework, and to
B2 C2
provide important vertical dimensions related to interior walls. They may also be useful in delineating the extent and MR-JSW-KLM
DOOR NUMBERING patterns of wall finish materials. Admin Building at JSWSCPL Kalmeshwar Works
The text should be located parallel and close to the door, but clear of the door swing line.
Door number are given as: CLIENT: JSW Steel Coated Products LTD.
D - standard door Determining Which Interior Elevations to Draw
GD - glass door Too often, architects are unpleasantly surprised by what they see on a job site because a particular interior wall was not
DW - door window combined elevated in the document set. Any interior wall containing any of the following should be elevated:
A-10/1, MIDC Industrial Area, SH265, Kalmeshwar-441501
SD - sliding door · Casework or atypical trim Nagpur-Maharashtra (India) TEL NO:917118271401
It is often necessary to enlarge portions of a floor plan so that dimensions and other information can be more clearly presented. · Interior windows or other atypical openings
These drawings comprise the “A5” series of drawings. Restrooms and stairs are usually among the areas enlarged.Partition types, · A change in finish materials EDIFICE CONSULTANTS PVT. LTD.
FIRST FLOOR PLAT 2A UJAGAR INFOTECH PARK
OPPOSITE DEONAR BUS DEPOT SUNDAR BAUG GOVANDI EAST,
door numbers and interior elevation symbols should NOT be used on the enlarged plans. Those symbols should appear in 1/8” scale · Signage MUMBAI,MAHARASHTRA - 400088, TEL NO: 022 6155 1111
plans only. The enlarges plans are suited only for dimensioning and, in some cases, for depiction of flooring patterns. · Any design feature which we consider important
MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
PURPOSE OF RELEASE
When a room is duplicated in plan a number of times, it is acceptance to elevate one such room as 'typical'. A general SCHEMATIC DESIGN
Exterior Elevation Symbol note on the floor plan should clearly state that the interior elevations of that typical room apply to others like it. However, STAGE: SD
Every exterior surface of the building must be elevated. Never assume the contractor understands what is required on
as un-drawn elevation. any wall which differs from the typical condition must be elevated separately if we consider it important we do not use a DIRECTION: Drawing No: Current
Revision:
note of 'similar' on interior elevations. You should ask yourself two questions which deciding whether to draw a particular N
Section Symbols G-0002 R0
In deciding where to cut a section, look for a place which will provide the most opportunities to define the vertical interior wall:
aspects of the building. · Does it differ from all previously drawn elevations ? Start Date: Issue Date: Last saved Date:
01-Jan-23 28-07-2023 28-Jul-23
· Is it an important wall according to the criteria listed above ? Project Code: MR-JSW-KLM
Bldng/Block: ADMIN. BUILDING
Floor: -
Drawing
title:
DRAWING DOCUMENTATION-2
F:\Corp Arch\MR-JSW-KLM\11. SCHEMATIC DESIGN\1. DRAWINGS\MR-JSW-KLM - SD
File path: COVER SHEET-G0001-G0002-G0003 - 20230529.dwg
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
DRAWING DOCUMENTATION-3
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
15
STORAGE BAY
GALVALUME 2
GD1 2000 X 3000 -- 3000 GLASS SLIDING DOORS Edifice Consultants Pvt. Ltd COLOUR COATING LINE 1
1200 X 3000 --
ARCHITECTURAL SD STAGE DRAWING LIST
GD2 3000 SINGLE SHUTTER GLASS DOORS
CLIENT MR-JSW-KLM PROJECT CODE V
RAMP
Paint Storage
A COLUMN CENTERLINE
D1 1200 X 3000 -- 3000 SINGLE SHUTTER DOORS
DRAWING LIST - TRANSMITTAL
DRAFT
D2 900 X 3000 -- 3000 SINGLE SHUTTER DOORS
900 X 3000 TWO WAY SWING DOOR- HANDICAP TOILET KEY PLAN
GRAVEL/BALLAST D3 -- 3000 0.0
D4 750 X 2100 -- 2400 SINGLE SHUTTER DOORS Sl No. Item Description Drawing Number Revision Number NTS
X DETAIL NO. SD1 600 X 1200 600 2400 SINGLE SHUTTER FIRE RATED METAL DOORS
RO R1 R2
SD2 450 X 1200 1000 2400 SINGLE SHUTTER FIRE RATED METAL DOORS
Y DRAWING NO.
STONE
ARCHITECTURAL DRAWINGS BLOCK PROJECT CODE STREAM STAGE DWG. NO. NAME OF DESIGNER TARGET DATE
SCHEDULE OF WINDOW OPENINGS (FROM FFL)
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION
SECTION/ELEVATION NO.
1 W1 750 X 1000 1200 2200 CASEMENT WINDOW
402 SHEET NO. 200 THK BRICK WALL COVER SHEET 0000
SHAFT CUTOUT SCHEDULE (A) GENERAL INFORMATION
1.00 Drawing Documentation-01 ADMIN MR-JSW-KLM G SD 0001 SONALI 20-04-2023 28-07-2023
SHAFT NO SIZE SERVICE
PL-1 300X600MM PLUMBING SHAFT
PL-2
2.00 Drawing Documentation-02 ADMIN MR-JSW-KLM G SD 0002 SONALI 20-04-2023 28-07-2023
200X2360MM PLUMBING SHAFT
150 MM THK. CONCRETE
WALL FINISH PL-3 764X450MM PLUMBING SHAFT
BLOCK WALL 3.00 Drawing Index, Abbreviations, Symbols, Area & ADMIN MR-JSW-KLM G SD 0003 SONALI 20-04-2023 28-07-2023
RELGH/ED/XXX -DETAIL DRAWING NO. FS 1000X600MM FIRE FIGHTING SHAFT
Occupancy Matrix
ELEC 600X1200MM ELECTRICAL SHAFT
XXX
DATA 800X600MM DATA SHAFT
WLL CLG CEILING MATERIAL (B) ARCHITECTURAL DRAWINGS
HVAC 1150X600MM HVAC SHAFT (1) LAYOUT PLANS
SKR FLR EX 700X600MM EXHAUST SHAFT 4.00 Layout - Ground floor plan ADMIN MR-JSW-KLM A SD 1101 SONALI 14-04-2023 28-07-2023
FLOORING MATERIAL PAVED AREA
LIFT SHAFT 2500X1800MM LIFT SHAFT
SKIRTING MATERIAL FS 1000X600MM 5.00 Layout - First floor plan ADMIN MR-JSW-KLM A SD 1102 SONALI 14-04-2023 28-07-2023
FIRE FIGHTING SHAFT
TREE SCHEDULE 6.00 Layout - Terrace floor plan ADMIN MR-JSW-KLM A SD 1103 SONALI 14-04-2023 28-07-2023
SHAFT NO TREE NAME BOTTOM DIA (M) MAXIMUM DIA(M) HEIGHT (M)
1 TAMARIND 0.5 3 3
7.00 Layout - Roof plan ADMIN MR-JSW-KLM A SD 1104 SONALI 14-04-2023 28-07-2023
DETAIL NO. 2 KASSOD 1 7 10
5 EUCALYPTUS 2.5 8 16
6 0.6 4 4.5
GULMOHOR (2) EXTERIOR ELEVATIONS
7 EUCALYPTUS 1 4 12 8.00 Front, Rear & Side Elevation ADMIN MR-JSW-KLM A SD 2001 SONALI 14-04-2023 28-07-2023
8 MANGO 0.8 5 10
9 EUCALYPTUS 2.6 8 16
BREAK LINE
16 ASHOKA 0.35 1.5 3.5 11.00 ADMIN MR-JSW-KLM A SD 4002 SONALI 21-04-2023 28-07-2023
17 ASHOKA 0.35 1.5 3.5
Door Detail
18 ASHOKA 0.35 1.5 3.5 12.00 ADMIN MR-JSW-KLM A SD 4003 SONALI 21-04-2023 28-07-2023
19 0.35 1.5 3.5
Misc Detail
ASHOKA
TILE DROOP
20 ALMOND 2.5 15 16 13.00 ADMIN MR-JSW-KLM A SD 4004 SONALI 21-04-2023 28-07-2023
2.5 1 3
Facade Detail
21 ASHOKA
REVISION CLOUD 31-05-2023 SS BS FIRST ISSUE
22 MANGO 1.3 10 12
ON HOLD CLOUD
CEILING TYPE
NORTH ARROW
FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
CLIENT RESPONDENT (Name & Designation) SANJEEV GOYAL - Head Technical Services & Projects
MEP CONSULTANTS:
Radiant Consulting Engineers
"RECEPTION & EXECUTIVE 4 seater MEETING 6 seater CONFERENCE "TRAINING
WORKSTATION CUBICAL CABIN BOARD ROOM ASSOCIATED ROOMS AREA (SQM) AREA (SQFT)
ALL DIMENSIONS ARE GIVEN WAITING" CABIN ROOM MEETING ROOM ROOM ROOM"
3500 FROM UNFINISH FACE TO UNFINISH
FACE UNLESS OTHER WISE NOTED Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
Koparkhairane, Navi Mumbai, Maharashtra-400701, TEL NO:022-27782040
OFFICE BLOCK
PROJECT:
PURPOSE OF RELEASE
SCHEMATIC DESIGN
REQUIRED 1.00 34.00 9.00 6.00 5.00
STAGE: SD
DIRECTION: Drawing No: Current
TOTAL AREA OF DEVELOPMENT 1325.00 14262 Revision:
N
G-0003 R0
Start Date: Issue Date: Last saved Date:
01-Jan-23 28-07-2023 28-Jul-23
Project Code: MR-JSW-KLM
Bldng/Block: ADMIN. BUILDING
Floor: -
Drawing
title:
DRAWING DOCUMENTATION-3
F:\Corp Arch\MR-JSW-KLM\11. SCHEMATIC DESIGN\1. DRAWINGS\MR-JSW-KLM - SD
File path: COVER SHEET-G0001-G0002-G0003 - 20230529.dwg
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
SCHEDULE OF WINDOW OPENINGS (FROM FFL) SCHEDULE OF DOOR OPENINGS (FROM FFL)
SLOPE
SLOPE
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION
W1 600 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING GD1 2000 X 3000 -- 3000 GLASS SLIDING DOORS
W2 800 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING GD2 1200 X 3000 -- 3000
15
SINGLE SHUTTER GLASS DOORS STORAGE BAY
SHAFT CUTOUT SCHEDULE GD4 900 X 3000 -- 3000 SINGLE SHUTTER GLASS DOORS
SHAFT NO SIZE SERVICE GD5 975 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-1 1550X300MM PLUMBING SHAFT GD6 1055 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-2 600X400MM PLUMBING +FIRE FIGHTING SHAFT GD7 1000 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING GALVALUME 2
LV 650X200MM DATA SHAFT D1 1200 X 3000 -- 3000 SINGLE SHUTTER DOORS COLOUR COATING LINE 1
HVAC 200X600MM HVAC SHAFT D2 900 X 3000 -- 3000 SINGLE SHUTTER DOORS
RAMP
LIFT SHAFT 2850X1950MM LIFT SHAFT D3 900 X 3000 -- 3000 TWO WAY SWING DOOR- HANDICAP TOILET V
Paint Storage
SLO
PE
SLO
PE
FS 300X300MM FIRE FIGHTING SHAFT D4 750 X 2100 -- 2400 SINGLE SHUTTER DOORS SOAK PIT
utility zone
EX 500X450MM PANTRY EXHAUST SHAFT SD1 600 X 1800 600 2400 SINGLE SHUTTER FIRE RATED METAL DOORS ROAD 15M WIDE
E
OP
SL
KEY PLAN
0.0
NTS
300MM WIDE DRAIN CHANNEL 300MM WIDE DRAIN CHANNEL 300MM WIDE DRAIN CHANNEL
SLOPE SLOPE SLOPE SLOPE SLOPE SLOPE TREE SCHEDULE
SHAFT NO TREE NAME BOTTOM DIA (M) MAXIMUM DIA(M) HEIGHT (M)
1 TAMARIND 0.5 3 3
2 KASSOD 1 7 10
10 MANGO 1.1 6 10
11 MANGO 0.9 5 5
15 MANGO 1.2 5 12
16 17
P E
18 19 21 ASHOKA 2.5 1 3
22 MANGO 1.3 10 12
A 1.5 8 12
23 NEEM
24 JAMUN 1.6 6 12
6000
DROP OFF
LEGENDS
ROAD FGL +102.40M
R.C.C. COLUMN & SLAB
22
R.C.C. RETAINING WALL / PCC
COLUMN STOPPING
10 FFL+102.43M
23 LEVEL DIFFERENCE
6000
TOC+102.35M TOC TOP OF CONCRETE
24000
FFL FINISH FLOOR LEVEL
C
24
VP VISION PANEL
SP SPANDREL PANEL
OP OPEN-ABLE PANEL
6000
1
2
SLOPE
5 7 9 25
LANDSCAPED 11
GREEN AREA
D
01 02 03 04 05 06 07
PROPOSED
R0 18-07-2023 AB BS FIRST ISSUE
300MM WIDE DRAIN CHANNEL
CAFETERIA
46900
REV. DRAWN CHECKED DESCRIPTION OF
6700 6700 6700 6700 6700 6700 6700 DATE
6000
NO. BY BY THE REVISIONS
REVISIONS
LANDSCAPE CONSULTANTS: AMS CONSULTANTS
310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
RECEPTION
6000
MEP CONSULTANTS:
F GD2 Radiant Consulting Engineers
GD3
GD3 GD3
TRAINING ROOM
300MM WIDE DRAIN CHANNEL
GD3 Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
6000
PROJECT:
GD2
UP
CLIENT: JSW Steel Coated Products LTD.
29 20 10 1
5100
GD5
TOILET (M)
W2 D2 PANTRY
D4 EDIFICE CONSULTANTS PVT. LTD.
FIRST FLOOR PLAT 2A UJAGAR INFOTECH PARK
OPPOSITE DEONAR BUS DEPOT SUNDAR BAUG GOVANDI EAST,
BATTERY RACK
SD1 MUMBAI,MAHARASHTRA - 400088, TEL NO: 022 6155 1111
5900
MH
UPS
J
DWT STAGE: SD
DIRECTION: Drawing No: Current
300MM WIDE DRAIN CHANNEL
W1 W1 Revision:
N
A-1101 R0
Start Date: Issue Date: Last saved Date:
01-Jan-23 28-Jul-23 25-Jul-23
Project Code: MR-JSW-KLM
Bldng/Block: ADMIN. BUILDING
Floor: GROUND FLOOR
Drawing
title:
GROUND FLOOR LAYOUT PLAN
GROUND FLOOR LAYOUT F:\Corp Arch\MR-JSW-KLM\11. SCHEMATIC DESIGN\1.
SCALE : 1: 100 File path: DRAWINGS\LAYOUTS\MR-JSW-KLM - SD LAYOUTS - 20230705.dwg
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
SCHEDULE OF WINDOW OPENINGS (FROM FFL) SCHEDULE OF DOOR OPENINGS (FROM FFL) CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION
W1 600 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING GD1 2000 X 3000 -- 3000 GLASS SLIDING DOORS
W2 800 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING GD2 1200 X 3000 -- 3000 SINGLE SHUTTER GLASS DOORS
15
STORAGE BAY
SHAFT CUTOUT SCHEDULE GD4 900 X 3000 -- 3000 SINGLE SHUTTER GLASS DOORS
SHAFT NO SIZE SERVICE GD5 975 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-1 1550X300MM PLUMBING SHAFT GD6 1055 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-2 600X400MM PLUMBING +FIRE FIGHTING SHAFT GD7 1000 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING GALVALUME 2
LV 650X200MM DATA SHAFT D1 1200 X 3000 -- 3000 SINGLE SHUTTER DOORS COLOUR COATING LINE 1
HVAC 200X600MM HVAC SHAFT D2 900 X 3000 -- 3000 SINGLE SHUTTER DOORS
RAMP
LIFT SHAFT 2850X1950MM LIFT SHAFT D3 900 X 3000 -- 3000 TWO WAY SWING DOOR- HANDICAP TOILET V
Paint Storage
FS 300X300MM FIRE FIGHTING SHAFT D4 750 X 2100 -- 2400 SINGLE SHUTTER DOORS SOAK PIT
utility zone
EX 500X450MM PANTRY EXHAUST SHAFT SD1 600 X 1800 600 2400 SINGLE SHUTTER FIRE RATED METAL DOORS ROAD 15M WIDE
KEY PLAN
0.0
NTS
LEGENDS
R.C.C. COLUMN & SLAB
15
12 13
14 R.C.C. RETAINING WALL / PCC
21
200MM THICK WALL
COLUMN STOPPING
LEVEL DIFFERENCE
6000
22
10 23
6000
6 8 R0 18-07-2023 AB BS FIRST ISSUE
24000
C
24 REVISIONS
6000
1
2
D' C
5 7 9 25
11
D
01 02 03 04 05 06 07
46900
6700 6700 6700 6700 6700 6700 6700
6000
TOC+106.85M
LANDSCAPE CONSULTANTS: AMS CONSULTANTS
310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
GD3
FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
B D
6000
STRUCTURAL CONSULTANTS:
GD3
MR. GIRISH WADHWA
CONSULTING STRUCTURAL ENGINEERS,
GD3 GD3 TOC+106.85M GD3 GD3
2nd Floor, Krushnakunj,3838-403, Opp Jain Derasar, RSC-26-27,Gorai 2, Borivali
A GD3 GD2 A' West, Mumbai 400092, Ph: =91 9821216010, Email: gIrish@gtwcse.in
GD3 GD3
MEP CONSULTANTS:
F Radiant Consulting Engineers
GD3
TOC+106.25M
GD4
GD3 Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
6000
PROJECT:
GD7
SD2
MR-JSW-KLM
23000
GD3
PL-3
G Admin Building at JSWSCPL Kalmeshwar Works
D1 D1
DN
CLIENT: JSW Steel Coated Products LTD.
29 20 10 1
5100
FFL+106.95M
SD1 TOC+106.85M A-10/1, MIDC Industrial Area, SH265, Kalmeshwar-441501
Nagpur-Maharashtra (India) TEL NO:917118271401
H FS EX PROJECT ARCHITECTS:
J.C.
SD1
HVAC
TOILET (M)
W2 D2 PANTRY
B D4 EDIFICE CONSULTANTS PVT. LTD.
FIRST FLOOR PLAT 2A UJAGAR INFOTECH PARK
OPPOSITE DEONAR BUS DEPOT SUNDAR BAUG GOVANDI EAST,
SD1 B' MUMBAI,MAHARASHTRA - 400088, TEL NO: 022 6155 1111
5900
TOILET (H) D3
SD1 PL-2
MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
PURPOSE OF RELEASE
W2 PL-1
D1
LIFT
13 PAX
LIFT LOBBY SCHEMATIC DESIGN
STORE 3200 X 5500
TOILET (F) D2 3150 X 1700 2800 X 1950
D4
J
STAGE: SD
DIRECTION: Drawing No: Current
W1 W1 Revision:
N
A-1102 R0
Start Date: Issue Date: Last saved Date:
01-Jan-23 28-Jul-23 25-Jul-23
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
SCHEDULE OF WINDOW OPENINGS (FROM FFL) SCHEDULE OF DOOR OPENINGS (FROM FFL) CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION
W1 600 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING GD1 2000 X 3000 -- 3000 GLASS SLIDING DOORS
W2 800 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING GD2 1200 X 3000 -- 3000
15
SINGLE SHUTTER GLASS DOORS STORAGE BAY
SHAFT CUTOUT SCHEDULE GD4 900 X 3000 -- 3000 SINGLE SHUTTER GLASS DOORS
SHAFT NO SIZE SERVICE GD5 975 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-1 1550X300MM PLUMBING SHAFT GD6 1055 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-2 600X400MM PLUMBING +FIRE FIGHTING SHAFT GD7 1000 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING GALVALUME 2
HVAC 200X600MM HVAC SHAFT D2 900 X 3000 -- 3000 SINGLE SHUTTER DOORS
RAMP
LIFT SHAFT 2850X1950MM LIFT SHAFT D3 900 X 3000 -- 3000 TWO WAY SWING DOOR- HANDICAP TOILET V
Paint Storage
FS 300X300MM FIRE FIGHTING SHAFT D4 750 X 2100 -- 2400 SINGLE SHUTTER DOORS SOAK PIT
utility zone
EX 500X450MM PANTRY EXHAUST SHAFT SD1 600 X 1800 600 2400 SINGLE SHUTTER FIRE RATED METAL DOORS ROAD 15M WIDE
KEY PLAN
0.0
NTS
LEGENDS
R.C.C. COLUMN & SLAB
COLUMN STOPPING
LEVEL DIFFERENCE
08 09
A TOC TOP OF CONCRETE
SP SPANDREL PANEL
OP OPEN-ABLE PANEL
6000
B
6000
R0 18-07-2023 AB BS FIRST ISSUE
24000
C REVISIONS
6000
D' C
01 02 03 04 05 06 07
46900
6700 6700 6700 6700 6700 6700 6700
6000
LANDSCAPE CONSULTANTS: AMS CONSULTANTS
310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
B D
6000
STRUCTURAL CONSULTANTS:
F
MEP CONSULTANTS:
Radiant Consulting Engineers
RIDGE
SLO
SLO
SLO
PE
PE
PE
SLO
SLO
SLO
PE
PE
PE
PROJECT:
MR-JSW-KLM
23000
TOC+111.35M
5100
ODU-3 PL-2
D2 MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
30
PURPOSE OF RELEASE
PL-1
LIFT SCHEMATIC DESIGN
ODU-4 ODU-5 ODU-6 MRL
J
STAGE: SD
DIRECTION: Drawing No: Current
Revision:
N
A-1103 R0
Start Date: Issue Date: Last saved Date:
01-Jan-23 28-Jul-23 25-Jul-23
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
SCHEDULE OF WINDOW OPENINGS (FROM FFL) SCHEDULE OF DOOR OPENINGS (FROM FFL) CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION
W1 600 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING GD1 2000 X 3000 -- 3000 GLASS SLIDING DOORS
SEMI-UNITIZED OPENABLE GLAZING GD2 --
15
W2 800 X 1000 1200 3000 1200 X 3000 3000 SINGLE SHUTTER GLASS DOORS STORAGE BAY
SHAFT CUTOUT SCHEDULE GD4 900 X 3000 -- 3000 SINGLE SHUTTER GLASS DOORS
SHAFT NO SIZE SERVICE GD5 975 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-1 1550X300MM PLUMBING SHAFT GD6 1055 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
PL-2 600X400MM PLUMBING +FIRE FIGHTING SHAFT GD7 1000 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
GALVALUME 2
HVAC 200X600MM HVAC SHAFT D2 900 X 3000 -- 3000 SINGLE SHUTTER DOORS
RAMP
LIFT SHAFT 2850X1950MM LIFT SHAFT D3 900 X 3000 -- 3000 TWO WAY SWING DOOR- HANDICAP TOILET V
Paint Storage
FS 300X300MM FIRE FIGHTING SHAFT D4 750 X 2100 -- 2400 SINGLE SHUTTER DOORS SOAK PIT
utility zone
EX 500X450MM PANTRY EXHAUST SHAFT SD1 600 X 1800 600 2400 SINGLE SHUTTER FIRE RATED METAL DOORS ROAD 15M WIDE
KEY PLAN
0.0
NTS
LEGENDS
R.C.C. COLUMN & SLAB
COLUMN STOPPING
LEVEL DIFFERENCE
08 09
A TOC TOP OF CONCRETE
SP SPANDREL PANEL
OP OPEN-ABLE PANEL
6000
B
6000
R0 18-07-2023 AB BS FIRST ISSUE
24000
NO. BY BY THE REVISIONS
C REVISIONS
6000
D' C
01 02 03 04 05 06 07
46900
6700 6700 6700 6700 6700 6700 6700
6000
LANDSCAPE CONSULTANTS: AMS CONSULTANTS
310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
B D
6000
STRUCTURAL CONSULTANTS:
MEP CONSULTANTS:
F Radiant Consulting Engineers
PROJECT:
MR-JSW-KLM
23000
B
O
MH
PE
TOC+114.55M
SLO
MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
PURPOSE OF RELEASE
TOC+114.55M
SCHEMATIC DESIGN
MH
J
STAGE: SD
DIRECTION: Drawing No: Current
Revision:
N
A-1104 R0
Start Date: Issue Date: Last saved Date:
01-Jan-23 28-Jul-23 25-Jul-23
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
SCHEDULE OF DOOR OPENINGS (FROM FFL) 7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
J H G F E D C B A TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION 8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
15
STORAGE BAY
3200
TERRACE PARAPET +112.55M GD6 1055 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
GD7 1000 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
1200
GALVALUME 2
600
T.O.C = +111.35 M COLOUR COATING LINE 2
FACADE CONSULTANT'S D3 900 X 3000 -- 3000 TWO WAY SWING DOOR- HANDICAP TOILET RAMP
4500
V
Paint Storage
DETAILS
3900
OP OP OP OP D4 750 X 2100 -- 2400 SINGLE SHUTTER DOORS
utility zone
12550
SOAK PIT
SD1 600 X 1800 600 2400 SINGLE SHUTTER FIRE RATED METAL DOORS
ROAD 15M WIDE
600
T.O.C = +106.85M KEY PLAN
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION 0.0
NTS
W1 600 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING
4500
3900
OP OP
350
PL-2 600X400MM PLUMBING +FIRE FIGHTING SHAFT
PL-3
LEGENDS
315X300MM PLUMBING SHAFT
ROAD FGL R.C.C. COLUMN & SLAB
EL 800X200MM ELECTRICAL SHAFT
+102M LV 650X200MM DATA SHAFT
R.C.C. RETAINING WALL / PCC
ELEVATION-D HVAC 200X600MM HVAC SHAFT
04
1:100 LIFT SHAFT 2850X1950MM LIFT SHAFT
200MM THICK WALL
LEVEL DIFFERENCE
01 02 03 04 05 06 07 08 09
TOC TOP OF CONCRETE
FL FINISHED LEVEL
3200
TERRACE PARAPET +112.55M
VP VISION PANEL
1200
TERRACE FFL = +111.55M SP SPANDREL PANEL
SP SP SP SP SP SP
600
T.O.C = +111.35 M OP OPEN-ABLE PANEL
D GLASS DOOR
4500
3900
OP VP OP VP OP VP OP VP OP W1 OP W1 OP OP VP OP VP
12550
GLAZING AS PER
FACADE CONSULTANT'S
DETAILS
FIRST FFL = +106.95M
600
T.O.C = +106.85M
4500
3900
OP VP OP VP OP VP OP VP OP W1 OP W1 OP GD6 VP OP SP OP VP OP VP SP
350
REV. DRAWN CHECKED DESCRIPTION OF
DATE
NO. BY BY THE REVISIONS
ROAD FGL REVISIONS
+102M
ELEVATION-C
03
1:100
A B C D E F G H J
MUMTY+114.55M
3200
TERRACE PARAPET +112.55M
1200
TERRACE FFL = +111.55M
600
T.O.C = +111.35 M
GLAZING AS PER FACADE LANDSCAPE CONSULTANTS: AMS CONSULTANTS
CONSULTANT'S DETAILS
4500
OP
3900
OP OP OP 310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
12550
Off DUKES FACTORY ROAD, CHEMBUR, MUMBAI - 71
Tel.:- 2520 7678 E-mail :- amsconsultants@gmail.com
FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
FIRST FFL = +106.95M
600
T.O.C = +106.85M
STRUCTURAL CONSULTANTS:
4500
MR. GIRISH WADHWA
3900
OP OP OP OP CONSULTING STRUCTURAL ENGINEERS,
2nd Floor, Krushnakunj,3838-403, Opp Jain Derasar, RSC-26-27,Gorai 2, Borivali
West, Mumbai 400092, Ph: =91 9821216010, Email: gIrish@gtwcse.in
350
ROAD FGL
+102M Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
ELEVATION-B Koparkhairane, Navi Mumbai, Maharashtra-400701, TEL NO:022-27782040
02
1:100 PROJECT:
MR-JSW-KLM
Admin Building at JSWSCPL Kalmeshwar Works
09 08 07 06 05 04 03 02 01
3200
TERRACE PARAPET +112.55M
A-10/1, MIDC Industrial Area, SH265, Kalmeshwar-441501
1200
Nagpur-Maharashtra (India) TEL NO:917118271401
TERRACE FFL = +111.55M
SP SP SP SP SP SP SP SP SP SP SP SP
600
T.O.C = +111.35 M PROJECT ARCHITECTS:
4500
FIRST FLOOR PLAT 2A UJAGAR INFOTECH PARK
3900
FACADE CONSULTANT'S OPPOSITE DEONAR BUS DEPOT SUNDAR BAUG GOVANDI EAST,
OP VP OP VP OP VP OP VP OP VP OP VP OP VP OP VP OP VP OP VP OP VP OP VP
12550
MUMBAI,MAHARASHTRA - 400088, TEL NO: 022 6155 1111
DETAILS
MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
SCHEMATIC DESIGN
600
T.O.C = +106.85M
STAGE: SD
DIRECTION: Drawing No: Current
4500
Revision:
3900
VP VP VP VP VP VP VP VP VP VP VP VP
JSW OP OP OP OP OP OP OP OP OP OP OP OP N
A-2001 R0
GROUND FFL = +102.45M
Start Date: Issue Date: Last saved Date:
T.O.C = +102.35M
350
01-Jan-23 28-Jul-23 28-Jul-23
SCALE : 1: 100 THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
G F E PRIOR TO THE COMMENCEMENT OF WORK.
SCHEDULE OF DOOR OPENINGS (FROM FFL) 7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION
MUMTY+114.55M GD1 2000 X 3000 -- 3000 GLASS SLIDING DOORS
15
STORAGE BAY
3200
900 X 3000 -- 3000 SINGLE SHUTTER GLASS DOORS
TERRACE PARAPET +112.55M GD5 975 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
1200
GD6 1055 X 3000 -- 3000 SEMI-UNITIZED OPENABLE GLAZING
TERRACE FFL = +111.55M
JD M10x30
1200
GALVALUME 2
600
T.O.C = +111.35 M TRANSFER CAR GAL STORAGE BAY
600
COLOUR COATING LINE 2
4500
D2 -- 3000
OP VP OP VP OP
3900
D3 900 X 3000 -- 3000 TWO WAY SWING DOOR- HANDICAP TOILET
3000
RAMP
12550
V
Paint Storage
SD1 600 X 1800 600 2400 SINGLE SHUTTER FIRE RATED METAL DOORS
OFFICE AREA
FIRST FFL = +106.95M
ROAD 15M WIDE
JD M10x30
600
T.O.C = +106.85M
SCHEDULE OF WINDOW OPENINGS (FROM FFL) KEY PLAN
600
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION 0.0
NTS
W1 600 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING
4500
OP VP OP VP OP
3900
W2 800 X 1000 1200 3000 SEMI-UNITIZED OPENABLE GLAZING
3000
OFFICE AREA
GROUND FFL = +102.45M SHAFT CUTOUT SCHEDULE
T.O.C = +102.35M SHAFT NO SIZE SERVICE
350
PL-1 1550X300MM PLUMBING SHAFT
LEVEL DIFFERENCE
MUMTY+114.55M TOC TOP OF CONCRETE
3200
FL FINISHED LEVEL
TERRACE PARAPET +112.55M
275
525
FFL FINISH FLOOR LEVEL
1200
TERRACE
TERRACE FFL = +111.55M
JD M10x30
VP VISION PANEL
600
T.O.C = +111.35 M SP SPANDREL PANEL
OP OPEN-ABLE PANEL
4825
4500
OP VP OP VP OP
3900
12550
JD M10x30
OFFICE AREA PASSAGE TOILET (M) TOILET (H) TOILET (F)
FIRST FFL = +106.95M
600
T.O.C = +106.85M
325
250
300
4500
3900
3600
300 GD5
350
R0 18-07-2023 AB BS FIRST ISSUE
ROAD FGL REV. DRAWN CHECKED DESCRIPTION OF
DATE
+102M NO. BY BY THE REVISIONS
REVISIONS
SECTION-C
03
1:100
01 02 03 04 05 06 07 08 09
MUMTY+114.55M
PROPOSED OHT
ODU
3200
TERRACE PARAPET +112.55M
1000
MUMTY
1200
TERRACE FFL = +111.55M
600
SP SP SP SP SP SP T.O.C = +111.35 M
4500
3900
OP VP OP VP OP VP OP VP OP OP VP OP VP
12550
310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
Off DUKES FACTORY ROAD, CHEMBUR, MUMBAI - 71
Tel.:- 2520 7678 E-mail :- amsconsultants@gmail.com
600
T.O.C = +106.85M
STRUCTURAL CONSULTANTS:
4500
3900
OP
OP VP OP VP OP VP OP VP GD6 VP OP SP OP VP OP VP SP MR. GIRISH WADHWA
CONSULTING STRUCTURAL ENGINEERS,
2nd Floor, Krushnakunj,3838-403, Opp Jain Derasar, RSC-26-27,Gorai 2, Borivali
TOILET (M) PASSAGE UPS STORAGE ROOM PANTRY PASSAGE West, Mumbai 400092, Ph: =91 9821216010, Email: gIrish@gtwcse.in
GROUND FFL = +102.45M
T.O.C = +102.35M
MEP CONSULTANTS:
Radiant Consulting Engineers
350
ROAD FGL
+102M
Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
Koparkhairane, Navi Mumbai, Maharashtra-400701, TEL NO:022-27782040
SECTION-B
02
1:100 PROJECT:
MR-JSW-KLM
Admin Building at JSWSCPL Kalmeshwar Works
01 02 03 04 05 06 07 08 09
CLIENT: JSW Steel Coated Products LTD.
MUMTY+114.55M
3200
+112.55M
TERRACE PARAPET A-10/1, MIDC Industrial Area, SH265, Kalmeshwar-441501
Nagpur-Maharashtra (India) TEL NO:917118271401
1200
JD M10x30 JD M10x30
600
T.O.C = +111.35 M
EDIFICE CONSULTANTS PVT. LTD.
FIRST FLOOR PLAT 2A UJAGAR INFOTECH PARK
OPPOSITE DEONAR BUS DEPOT SUNDAR BAUG GOVANDI EAST,
4500
1800
3900
OP OP OP OP OP OP OP OP OP OP OP OP MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
12550
PURPOSE OF RELEASE
1200
JD M10x30 JD M10x30
FIRST FFL = +106.95M
600
T.O.C = +106.85M STAGE: SD
DIRECTION: Drawing No: Current
Revision:
N
4500
1800
A-3001 R0
3900
OP OP OP OP OP OP OP OP OP OP OP OP
1200
350
Bldng/Block: ADMIN. BUILDING
ROAD FGL Floor: -
+102M
Drawing
title:
SECTIONS
SECTION-A
01 File path:
F:\Corp Arch\MR-JSW-KLM\11. SCHEMATIC DESIGN\1.
1:100 DRAWINGS\SECTIONS\MR-JSW-KLM - SD SECTIONS - 20230724.dwg
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
950 950 950 950 950 950 950 950 950 950 950 335 3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
850 1150 850 6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
1050
1050
PRIOR TO THE COMMENCEMENT OF WORK.
7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
MUMTY = +114.55M 8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
30
29 FIRST FFL = +5.05M
28 T.O.C = +4.95M
850 1150 850 1150 27
1050
26
15
STORAGE BAY
FIRST FFL = +5.05M
25
T.O.C = +4.95M
23 24
1050
22
21 FLIGHT-03
20
19
18
850 1150 850 1150 17 PLAN PLAN TERRACE PARAPET +112.55M
1050
GALVALUME 2
16 Y Y
15 TRANSFER CAR GAL STORAGE BAY
14
1050
13 COLOUR COATING LINE 2
12 32
11 31 COLOUR COATING LINE 1
10 FLIGHT-02 30 30
29 TERRACE FFL = +111.55M
1050
9 29
8 28 28 T.O.C = +111.35 M RAMP
7 FLIGHT-06 27 27 V
Paint Storage
6 26 26
utility zone
5 25 25 SOAK PIT
4 FLIGHT-01 24 24
23 FLIGHT-06
1050
3 23 ROAD 15M WIDE
2 22 22
1 21 21 FLIGHT-05
20 20
GROUND FFL = +0.45M 19 19
T.O.C = +0.35M 18
FLIGHT-05 18 KEY PLAN
17 17 0.0
GROUND FFL = +0.45M
ROAD FFL = ±0.0M
PLAN 16
FLIGHT-04
PLAN 16 NTS
15 15
T.O.C = +0.35M X 14 X FLIGHT-04 14
ROAD FFL = ±0.0M 13 13
12 FLIGHT-03 12
11 11
ENLARGED SECTION-C 10 FLIGHT-03 10
10 9
1: 50 FLIGHT-03 9
8 8
ENLARGED SECTION-D 7 7
08 6
1: 50 FLIGHT-02 6
5 5
4 4
FLIGHT-01 3 3 FLIGHT-02
PASSAGE 2 PANTRY PASSAGE
2
1 1 FLIGHT-01 LEGENDS
FIRST FFL = +106.95M
T.O.C = +106.85M R.C.C. COLUMN & SLAB
1050
COLUMN STOPPING
PASSAGE 30 EQ
30 29
FIRST FFL = +5.05M FIRST FFL = +5.05M LEVEL DIFFERENCE
29 28
T.O.C = +4.95M 1188 T.O.C = +4.95M
28 27
27 26 TOC TOP OF CONCRETE
1050
26 25 EQ FLIGHT-02
25 24
24 23 FGL FINISHED GROUND LEVEL
1050
23 22
22 FLIGHT-03
21 FL FINISHED LEVEL
21 EQ
20 20
19 19
18 1188 FFL FINISH FLOOR LEVEL
18 FLIGHT-01
17 IT HARDWARE ROOM UPS BATTERY LT PANEL ROOM
17
16 16
15 EQ
PASSAGE UPS STORAGE ROOM PANTRY PASSAGE
ROOM VP VISION PANEL
15
14 14
SP SPANDREL PANEL
1050
13 13 GROUND FFL = +102.45M
FLIGHT-02 12
12 T.O.C = +102.35M
11 11 ROAD FGL
10 EQ OP OPEN-ABLE PANEL
10
GD5 +102M
1050
9 9
8 8
7 7
6 6
5 5
4 4
1050
3 FLIGHT-01 3
2 2
1 PASSAGE 1
GROUND FFL = +0.45M GROUND FFL = +0.45M
T.O.C = +0.35M T.O.C = +0.35M
ROAD FFL = ±0.0M ROAD FFL = ±0.0M
1: 50 D 1: 50
75MMØ X8MM THK MS BASE
PLATE WITH M8X100 CSK
ANCHORS R0 18-07-2023 AB BS FIRST ISSUE
SEC
A
REV. DRAWN CHECKED DESCRIPTION OF
SEC
38MMØ & 1.5MM THK DATE
F HANDRAIL(MS) NO. BY BY THE REVISIONS
REVISIONS
100
GROOVE AS PER DETAILS
1000
100
1050
1000 21 22 23 CEMENT MORTAR AS PER
DETAILS & SPEC.
01
300
150
NOSING EDGE AS PER
25
18 DETAIL & SPEC.
HVAC
SEC B B SEC 26
SEC DN SEC 17
1800
C C
16
27 10 EQ
1050
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
15
28
32 31 30
DETAILS & SPEC. 8
FLIGHT-03 FLIGHT-02 FLIGHT-01
E DN 1000
E SKIRTING JOINT AS PER 7
D1 DETAILS & SPEC.
FIRST FLOOR PLAN SEC SEC
04 1975 300 1075
6
1: 50 (FIRST RISER / 1st RISER OF THE KOTA FINISH AS PER DETAILS
STAIRCASE WILL BE 200 MM @ TOC ) & SPEC. 5
4
SEC
1050
SLAB AS PER STRUCTURAL
DETAIL & SPEC.
FLIGHT-01 3
2
SEC
13.
SCALE: 1:10
1
TERRACE FLOOR PLAN - (PLAN AT A-A) FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
06
1: 50
SEC
D
SEC
SEC
1000
UP 300
D1 D2
3 CEMENT MORTAR AS PER
1 2 DETAILS & SPEC.
200
4
100
19
2700 1500 2700 1500 2700 5
200
18 Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
GD2
100
HVAC
SD1
150MM SKIRTING AS PER Koparkhairane, Navi Mumbai, Maharashtra-400701, TEL NO:022-27782040
1550
50
17
1800
200
7
1800
16 PROJECT:
C SEC SEC C
150
8 KOTA FINISH AS PER DETAILS
15
200
& SPEC.
11100 9
250
14 50
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
13 12 11 10 MR-JSW-KLM
230
38
400 1000
E E
1000
1000
19
FLIGHT-03 FLIGHT-02 FLIGHT-01 DETAIL & SPEC.
1475 600 1075
GROUND FLOOR PLAN
03 CLIENT: JSW Steel Coated Products LTD.
19
1: 50
1050
19
SEC
19
STAIRCASE WILL BE 100 MM @ TOC )
MUMBAI-DELHI-CHENNAI-KOLKATA-BENGALURU-HYDERABAD-PUNE-KOCHI
LANDSCAPED
GREEN AREA PURPOSE OF RELEASE
38MMØ MS HANDRAIL 38MMØ MS HANDRAIL
50 KOTA STONE AS PER DETAILS & SPEC. AS PER DETAIL AND
SCHEMATIC DESIGN
8
12MM THICK INTERNAL PLASTER AS
Ø3
PER SPEC. SPEC. 75
200
4 38MMØ MS HANDRAIL 19MMØ MS HANDRAIL
50
20
TOC+106.85M
BRACKET
200
25 25 4X4MM GROOVE POP FINISH 38MMØ X 1.5MM THK
STAGE: SD
100
GD3
GD3
GD3
200
Ø19 19MMØ MS HANDRAIL
4
6
50
DIRECTION:
4
200
35 6 RAIL BRACKET
GD3 FFL+102.45M
FFL+102.43M
GD3
TOC+102.35M
12MMØ MS HANDRAIL 50 Revision:
12MM THK PLASTER AS PER DETAILS
GD3
GD3 GD3 GD3 GD3
1050
200
GD2
N
GD3
A-4001 R0
GD3 50MMX50MM MS 50X50MM MS BALUSTER
1050
200
GD3 GD3
TRAINING ROOM
20MM THICK POLISHED BALUSTER 75MMØ X8MM THK MS BASE
50
GD3
GD4
GD3
200
PLATE WITH M8X100 CSK
1050
TERRACE
NOSING 12MM PROJECTED
APPROVED SAMPLE AND
150
200
GD3
50X50MM MS BALUSTER
PL-3 D1
GD2
PL-3
231
29 20 10 1
29 20 10 1
FLIGHT-03 FLIGHT-02 FLIGHT-01
231
01-Jan-23 28-JUL-23 19-Jul-23
FFL+102.45M FFL+106.95M
SD1
D2 SD1 TOC+106.85M
BASE PLATE WITH BOLT ENDS CUT TO
FS
D2
EX
FS EX 10MM THICK PLATE REFER
IT HARDWARE
SD1
SD1 FLUSH WITH PLASTER LINE KOTA STONE AS PER DETAILS & SPEC. FFL
WELDED Project Code: MR-JSW-KLM
ROOM
HVAC
DETAIL- 01
TOILET (M)
W2 D2 PANTRY
HVAC
D4
W2
D4
TOILET (M)
D2 PANTRY
TOC
TO BALUSTER
BATTERY RACK
SD1
UPS
200
ROOM TOILET (H) D3
SD1 PL-2
D1
LV
SD1
EL
SD1
KEY PLAN-02 W2 PL-1
15MMX140MM
D4 D1
13 PAX TOILET (F) D2 LIFT
19
D4
13 PAX
NTS W1
15
STORAGE BAY
GALVALUME 2
RAMP
DOOR CLOSER WITH G-N DOOR CLOSER WITH G-N DOOR CLOSER WITH G-N
V
Paint Storage
EN 2-5 B/G, FINISH SILVER EN 2-5 B/G, FINISH SILVER EN 2-5 B/G, FINISH SILVER
SOAK PIT
utility zone
KEY PLAN
0.0
NTS
1500
1500
1500
SCHEDULE OF DOOR OPENINGS (FROM FFL)
TYPE OPENING SIZE SILL HT. LINTEL HT. DESCRIPTION
GD1 GD1 2000 X 3000 -- 3000 AUTOMATIC GLASS SLIDING DOOR
3000
3000
3000
--
3000
3000
3000
3000
GD2 1200 X 3000 3000 SINGLE SHUTTER GLASS DOOR
300
300
300
DOOR HANDLE AS PER DOOR HANDLE AS PER DOOR HANDLE AS PER 900 X 3000
GD4 -- 3000 SINGLE SHUTTER GLASS DOOR
MANUFACTURERS SPEC. MANUFACTURERS SPEC. MANUFACTURERS SPEC.
1200
DOOR SHUTTER AS PER SD1 600 X 1500 900 2400 SINGLE SHUTTER FIRE RATED METAL DOOR
1200
1200
DOOR SHUTTER AS PER DOOR SHUTTER AS PER
MANUFACTURERS SPEC. MANUFACTURERS SPEC. MANUFACTURERS SPEC.
SLIDING DOOR AS
INSIDE AS PER MANUFACTURER SPECS. DOOR HINGE AS PER DOOR HINGE AS PER DOOR HINGE AS PER
MANUFACTURERS SPEC. MANUFACTURERS SPEC. MANUFACTURERS SPEC.
PLAN - GD2
SCALE: 1:20
PLAN - GD3
SCALE: 1:20
PLAN - GD3
SCALE: 1:20
01 01 01
REVISIONS
DOOR CLOSER WITH G-N 310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
300
EN 2-5 B/G, FINISH SILVER Off DUKES FACTORY ROAD, CHEMBUR, MUMBAI - 71
Tel.:- 2520 7678 E-mail :- amsconsultants@gmail.com
FACADE CONSULTANTS:
SYNERGY FACADE CONSULTANTS
RCC LINTEL RCC LINTEL 600
RCC LINTEL
EQ
EQ
RCC LINTEL
5 KNUCKLE, 2 BALL BEARING 5 KNUCKLE, 2 BALL BEARING 5 KNUCKLE, 2 BALL BEARING
900 750
5 KNUCKLE, 2 BALL BEARING BUTT HINGES BB3090F WITH BUTT HINGES BB3090F WITH BUTT HINGES BB3090F WITH STRUCTURAL CONSULTANTS:
METAL SCREWS SIZE 4"x3"x3MM 5 KNUCKLE, 2 BALL BEARING
BUTT HINGES BB3090F WITH
EQ 200 EQ BUTT HINGES BB3090F WITH
METAL SCREWS SIZE 4"x3"x3MM METAL SCREWS SIZE 4"x3"x3MM
MR. GIRISH WADHWA
200
200
METAL SCREWS SIZE 4"x3"x3MM GRADE SS 304- FINISH SSS GRADE SS 304- FINISH SSS GRADE SS 304- FINISH SSS
METAL SCREWS SIZE 4"x3"x3MM
GRADE SS 304- FINISH SSS CONSULTING STRUCTURAL ENGINEERS,
GRADE SS 304- FINISH SSS EQ 200 EQ
VISION PANEL OF 6MM THICK VISION PANEL OF 6MM THICK 2nd Floor, Krushnakunj,3838-403, Opp Jain Derasar, RSC-26-27,Gorai 2, Borivali
EQ
GLASS SIZE 200x300MM IN GLASS SIZE 200x300MM IN West, Mumbai 400092, Ph: =91 9821216010, Email: gIrish@gtwcse.in
EQ
1500
1500
EQ 200 EQ
600
600
EQ
EQ
( CLEAR DAY LIGHT 160x260MM) ( CLEAR DAY LIGHT 160x260MM)
VISION PANEL OF 6MM THICK
GLASS SIZE 200x300MM IN
GLASS SIZE 200x300MM IN
MEP CONSULTANTS:
Radiant Consulting Engineers
2 HOUR FIRE RATED DOOR
3000
3000
3000
300
2400
2400
EQ
EQ
EQ
DOOR SHUTTER AS PER MANUFACTURERS SPECS. Office No 210/Wing A1, Rupa Solitaire, Mahape,Sector-1 Millennium Business Park,
2100
2100
2100
2100
MANUFACTURERS SPECS.
LOCK & DOOR HANDLE LOCK & DOOR HANDLE DOOR FRAME AS PER Koparkhairane, Navi Mumbai, Maharashtra-400701, TEL NO:022-27782040
EXTERNAL TRIM WITH DESIGN LEVER AS PER SPECS. AS PER SPECS. MANUFACTURERS SPECS.
HANDLE WITH EURO PROFILE CYLINDER PROJECT:
RCC SILL
SILVER FINISH HALF CYLINDER ,40MM HONEY COMB HONEY COMB HONEY COMB
FOR PANIC EXIT DEVICE
1500
1350
1350
DOOR SHUTTER AS PER
1200
1200
1200
1200
1200
1200
1200
EQ
EQ
EQ
MANUFACTURERS SPEC. MANUFACTURERS SPECS.
900
900
1000
200
300
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
CP 648E 1-3/4 WRAP 7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
LAYERS WILL VARY 8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
PIPE ON DIAMETER
15
STORAGE BAY
(HDPE)
MIN 4" MINERAL WOOL (4 CONCRETE FLOOR THICKNESS WILL INCREASE FOR PIPE INSULATION
V
Paint Storage
16 PVC/PPR PIPES PASSING THROUGH SLAB 17 METAL PIPES PASSING THROUGH 18 HDPE PIPES PASSING THROUGH 19 METAL CONDUIT PASSING THROUGH SLAB 20 TYPICAL DETAILS FOR INSULATED PIPES 21 FIXING DETAILS OF DRAIN PIPES
Scale: N.T.S Scale: N.T.S
- Scale: N.T.S - PASSING THROUGH WALLS Scale: N.T.S - PASSING THROUGH WALLS Scale: N.T.S - Scale: N.T.S - PASSING THROUGH SLAB - FOR BATHTUB & WASH BASIN
KEY PLAN
0.0
NTS
SLAB
SLEEVE SEALANT INTUMESCENT FIRESTOP
PIPE 16 mm THICK INTUMESCENT SEALANT
(COPPER,GI,MS) SEALANT
UPTO 3" PIPE R.C.C. RETAINING WALL / PCC
FLEXIBLE ELASTOMERIC RUBBER
(PVC/PPR)
INSULATION
200MM THICK WALL
SLAB
FGL FINISHED GROUND LEVEL
12 TYPICAL DETAILS FOR PVC/PPR PIPES 13 TYPICAL DETAILS FOR METAL PIPES 14 TYPICAL DETAILS FOR GLASS/INSULATED PIPES 15 AB/PVC INSULATED PIPES
Scale: N.T.S Scale: N.T.S Scale: N.T.S
- PASSING THROUGH WALLS - PASSING THROUGH WALLS - PASSING THROUGH WALLS - PASSING THROUGH WALLS Scale: N.T.S FL FINISHED LEVEL
VP VISION PANEL
SP SPANDREL PANEL
G.I. DUCT
FLOOR DRAIN COVER LIGHT FILLING CONCRETE MIN 1/4" DEPTH
FS-ONE MAX TEMP. PVC SLEEVE /WOODEN CEMENT MORTAR GROUTING OP OPEN-ABLE PANEL
FFL BOX (TO BE REMOVED AFTER MIN. 1/4" DEPTH SLAB SLAB
30MM FINISH
WATER PROOFING CASTING)
100
REVISIONS
ROCK WOOL INSULATION ROCK WOOL INSULATION ROCK WOOL INSULATION ROCK WOOL INSULATION
3 mm THICK NON EXPANDABLE FIRE 3 mm THICK NON EXPANDABLE FIRE 3 mm THICK NON EXPANDABLE FIRE SEALANT 3 mm THICK NON EXPANDABLE FIRE
SEALANT SEALANT SEALANT
MUMTY +114.35M
G.I. SLEEVE G.I. SLEEVE G.I. SLEEVE
WALL
WALL
WALL
16 mm THICK INTUMESCENT 16 mm THICK INTUMESCENT 16 mm THICK INTUMESCENT SEALANT 16 mm THICK INTUMESCENT SEALANT
SEALANT SEALANT
FLEXIBLE ELASTOMERIC RUBBER FLEXIBLE ELASTOMERIC RUBBER FLEXIBLE ELASTOMERIC RUBBER INSULATION FLEXIBLE ELASTOMERIC RUBBER 310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
FACADE CONSULTANTS:
EXTERNAL GRADE PLASTER WITH SYNERGY FACADE CONSULTANTS
WATERPROOFING COMPOUND, LAID
WALL WALL G.I. DUCT WALL WALL CHW PIPE TO SLOPE INSIDE
WALL
WALL
MEP CONSULTANTS:
Radiant Consulting Engineers
RCC COVER SLAB AND BEAM
AS PER STRUCTURAL DRAWING
TERRACE PARAPET
04 TYPICAL DETAILS FOR DUCT PASSING THROUGH THE WALL 05 TYPICAL DETAILS FOR PIPE PASSING THROUGH THE WALL T.O.C = +112.75 M
- Scale: N.T.S - Scale: N.T.S
01 TYPICAL DETAILS FOR CABLE TRAY/TRUNKING 02 TYPICAL DETAILS FOR MULTIPLE PIPES PASSING THROUGH SLAB 03 DETAILS FOR DUCTS PASSING THROUGH SLAB Project Code: MR-JSW-KLM
- Scale: 1:25
OP OPENABLE GLAZING PANEL - PASSING THROUGH THE WALL /SLAB Scale: N.T.S - Scale: N.T.S Bldng/Block: ADMIN. BUILDING
Floor: GROUND, FIRST,TERRACE FLOOR
LV1 ALUMINIUM FINS WITH WOOD TEXTURE Drawing
title:
DETAILS
F:\Corp Arch\MR-JSW-KLM\11. SCHEMATIC DESIGN\1.
LV2
File path: DRAWINGS\DETAILS\MR-JSW-KLM - MISC DETAILS - 20230607.dwg
PRECAST RCC FINS WITH BIRD MESH
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.
NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
2. ALL LEVELS INDICATED ARE IN METERS UNLESS OR OTHERWISE SPECIFIED.
3. DIMENSIONS / LEVELS INDICATED ARE STRUCTURAL UNLESS OTHERWISE SPECIFIED.
4. THIS DRAWING, UNLESS OTHERWISE MENTIONED, TO BE PLOTTED TO MENTIONED PAPER SIZE.
5. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. DO NOT SCALE THE DRAWING.
6. DIMENSIONS / LEVELS SHOWN TO BE VERIFIED AT SITE BEFORE COMMENCEMENT OF
WORK, ANY DISCREPANCIES IF NOTED BE BROUGHT TO THE NOTICE OF ARCHITECT
PRIOR TO THE COMMENCEMENT OF WORK.
7. RELEVANT SERVICES DRAWINGS ARE TO BE READ SIMULTANEOUSLY AND PROVISION OF
CUTOUTS / SLEEVES TO BE PROVIDED AS REQUIRED.
8. ALL MATERIALS / FINISHES TO BE AS SPECIFIED AND APPROVED BY THE CONSULTANTS.
15
STORAGE BAY
AND SPECIFICATION AND SPECIFICATION
REFER
JD M10x30 JD M10x30
REFER
86
FLOOR FINISH LAID TO SLOPE ON CEMENT
APPROVED FLOOR FINISH LAID TO SLOPE
DETAIL- 08 DETAIL- 09 SCREED AS PER SPECIFICATIONS RAMP
Paint Storage
JD M10x30 JD M10x30 50MM THK CONCRETE SCREED WITH ROAD 15M WIDE
INTEGRAL WATERPROOFING COMPOUND
RCC SLAB PROJECTION AS PER AS PER STRUCTURAL
RCC SLAB PROJECTION AS PER STRUCTURAL DRAWING DRAWINGEXPOSED CONCRETE FINISH AS PER SPECIFICATION APPROVED FINISH LAID TO SLOPE RAIN WATER DOWNTAKE PIPE LINES AND
RCC SLAB AND PLINTH BEAM AS PER EXPOSED CONCRETE FINISH AS PER SPECIFICATION AS PER SPECIFICATION FIXING DETAILS AS PER SHOP DRAWING
STRUCTURAL DRAWING KEY PLAN
DRIP MOULD RCC BEAM WITH SLEEVE FOR RAINWATER 0.0
DRIP MOULD
PIPE AS PER STRUCTURAL DRAWING NTS
WATERPROOFING AS PER SPECIFICATION SPANDREL GLASS GLAZING PANEL
AS PER FACADE SPECIFICATION
RCC PROJECTION AS PER STRUCTURAL DRAWING MASONRY BLOCKWORK
EXPOSED CONCRETE FINISH AS PER SPECIFICATION
GLAZING ASSEMBLY AS PER FACADE ENTRANCE CANOPY SLAB AS PER STRUCTURAL DRAWING
SPECIFICATION EXPOSED CONCRETE FINISH AS PER SPECIFICATION CLEAR GLASS GLAZING PANEL AS
PER FACADE SPECIFICATION
DETAIL - 01 - PLINTH PROTECTION DETAIL - 02 - FIRST FLOOR OVERHANG DETAIL - 03 - ABOVE ENTRANCE DOOR DETAIL - 04 - TERRACE LEVEL OVERHANG DETAIL - 05 - RAINWATER DOWNTAKE LEGENDS
02 03 04 05 06
1:20 1:20 1:20 1:20 1:20 R.C.C. COLUMN & SLAB
COLUMN STOPPING
LEVEL DEFERENCE
FL FINISHED LEVEL
VP VISION PANEL
300
125
TERRACE PARAPET +112.75M DRIP MOULD IN PLASTER
1500
50
R1
1500
JD M10x30
10
JD M10x30
86
TO SLOPE OF 1:100 AS PER SPECIFICATIONS
140
200
METAL PLATE WITH FINISH MATCHING ELASTROMERIC SYNTHETIC MEMBRANE
TO GLAZING MULLIONS R0 31-05-2023 SS BS FIRST ISSUE
WATERPROOFING AS PER SPECIFICATION
600
REV. DRAWN CHECKED DESCRIPTION OF
DATE
50
NO. BY BY THE REVISIONS
300
50MM THK CONCRETE SCREED WITH
GLAZING ASSEMBLY AS PER FACADE INTEGRAL WATERPROOFING COMPOUND
REVISIONS
SPECIFICATION
DETAIL -05 : AEROFIN FIXING DETAIL - TOP PLAN: FACADE PROJECTION CORNER DETAIL TERRACE FLOORING TERMINATION DETAIL
09 11 13
1:5 1:20 1:5
100
DRIP MOULD IN PLASTER LANDSCAPE CONSULTANTS: AMS CONSULTANTS
100
GLAZING ASSEMBLY AS PER FACADE SPECIFICATION 310, ANURAG BUSINESS CENTRE, NEAR AMAR THEATRE
Off DUKES FACTORY ROAD, CHEMBUR, MUMBAI - 71
Tel.:- 2520 7678 E-mail :- amsconsultants@gmail.com
450
450
PLINTH BEAM AS PER
JD M10x30
FIRST FFL = +106.95M JD M10x30
STRUCTURAL DRAWING
T.O.C = +106.85M
STRUCTURAL CONSULTANTS:
300 300
MR. GIRISH WADHWA
CONSULTING STRUCTURAL ENGINEERS,
2nd Floor, Krushnakunj,3838-403, Opp Jain Derasar, RSC-26-27,Gorai 2, Borivali
150
LV TRENCH West, Mumbai 400092, Ph: =91 9821216010, Email: gIrish@gtwcse.in
THIS DRAWING IS THE SOLE PROPERTY OF EDIFICE CONSULTANTS PVT. LTD. IT'S USE FOR ANY
PURPOSE OTHER THAN THAT MENTIONED IS TO BE DONE ONLY AFTER PRIOR APPROVAL.