You are on page 1of 44

SDE030

SDE060
Directional control valves with direct acting solenoid
SDE030-SDE060
Features ____________________________________________________________________________________________________

Simple, compact and heavy duty designed sectional valve from 1 to 10 sections.
Different type of inlet covers.
Different types of spools.
Different options to be flanged on the ports side.
Available for parallel and series circuits.
Emergency handlever available.
On/off solenoid controls.

Additional information
This catalogue shows the product in the most standard configurations.
Please contact Sales Dpt. for more detailed information or special request.

WARNING!
All specifications of this catalogue refer to the standard product at this date.
Walvoil, oriented to a continuous improvement, reserves the right to
discontinue, modify or revise the specifications, without notice.

WALVOIL IS NOT RESPONSIBLE FOR ANY DAMAGE CAUSED BY AN


7th edition July 2014
INCORRECT USE OF THE PRODUCT.

2 D1WWEB02E
SDE030-SDE060
_________________________________________________________________________________________________________
Index

Contents
- Valve general information
Working conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Dimensional data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Hydraulic circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Complete sections ordering codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
- Inlet section
SDE030 inlet section parts odering codes . . . . . . . . . . . . . . . . . . . . . . . . . 10
SDE030 inlet section dimensions and circuit . . . . . . . . . . . . . . . . . . . . . . . . 11
SDE030 inlet section options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SDE060 inlet section parts ordering codes . . . . . . . . . . . . . . . . . . . . . . . . . 15
SDE060 inlet section dimensions and circuit . . . . . . . . . . . . . . . . . . . . . . . . 16
SDE060 inlet section options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
SDE030-SDE060 special inlet section: parts odering codes . . . . . . . . . . . . . 20
SDE030-SDE060 special inlet section: dimensions and circuit . . . . . . . . . . . 21
SDE030-SDE060 special inlet section: options . . . . . . . . . . . . . . . . . . . . . . 22
- Working section
Working section parts ordering codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Working section dimensions and circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Secondary port valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Spools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SDE030 spool control kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
SDE060 spool control kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
- Flangeable valve blocks
Antishock valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Check valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Solenoid operated check valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Counterbalance valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
- Outlet sections
Dimensional data and circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
- Accessories
Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Fixing brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
- Installation and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

D1WWEB02E 3
SDE030-SDE060 valve general informations

Working conditions _____________________________________________________________________________________

This catalogue shows technical specifications and diagrams measured with mineral oil of 46mm2/s - 46 cSt viscosity at 40°C -
104°F temperature.

SDE030 30 l/min 7.9 US gpm


Nominal flow rating
SDE060 60 l/min 15.8 US gpm
Operating pressure (max.) 315 bar 4600 psi
Back pressure (max.) outlet port T 210 bar 3050 psi
∆p = 100 bar - 1450 psi fluid and valve
Internal leakage (max.) A(B)⇒T 14 cm3/min 0,85 in3/min
at 40°C - 104°F
Fluid Mineral based oil

with NBR (BUNA-N) seals from -20°C to 80°C from -4°F to 176°F
Fluid temperature
with FPM (VITON) seals from -20°C to 100°C from -4°F to 212°F
operating range from 15 to 75 mm2/s from 15 to 75 cSt
Viscosity min. 12 mm s2
12 cSt
max. 400 mm2s 400 cSt
Max. contamination level -/19/16 - ISO 4406 NAS 1638 - class 10
Ambient temperature for working
from -20°C to 50°C from -4°F to 122°F
conditions
NOTE - For different conditions please contact Sales Dpt.

Standard threads ________________________________________________________________________________________

REFERENCE STANDARD
BSP UN-UNF

ISO 228/1 ISO 263


THREAD ACCORDING TO
BS 2779 ANSI B1.1 unified

ISO 1179 11926


CAVITY DIMENSION
SAE J11926
ACCORDING TO
DIN 3852-2 shape X or Y

PORTS THREADING SDE030 SDE060


BSP UN-UNF BSP UN-UNF

Inlet P and outlet T G 3/8 3/4-16 (SAE 8) G 1/2 3/4-16 (SAE 8)

G 3/8 9/16-18 (SAE 6)


Ports A and B G 3/8 9/16-18 (SAE 6)
G 1/2 * 3/4-16 (SAE 8) *
NOTE (*)- Optional thread

4 D1WWEB02E
valve general informations SDE030-SDE060
__________________________________________________________________________________________
Dimensional data

SDE030 directional valve


Dimensions are referred to directional valve with N1 type inlet section.

F 70
2.76
E 45
1.77

4.5
0.18
75.2
2.96

M8
A1 A2
28.5
1.12

220.5
31.5
2.76

3.54
1.24

8.68
70

34
23.5
0.93

B1 B2
0.049
1.25
0.18
4.5

10 23.5 37.5 46 38.5


0.39 0.93 1.48 1.81 1.52

type N inlet section type N1 inlet section (see drawing) type N2 inlet section
TYPE E F E F Weight E F
mm in mm in mm in mm in Kg lb mm in mm in
SDE030/1 80 3.15 110.5 4.35 103.5 4.07 134 5.28 4.58 10.10 128 5.04 158.6 6.24
SDE030/2 126 4.96 156.5 6.16 149.5 5.89 180 7.09 6.61 14.57 174 6.85 204.5 8.05
SDE030/3 172 6.77 202.5 7.97 195.5 7.70 226 8.90 8.64 19.05 220 8.66 250.5 9.86
SDE030/4 218 8.58 248.5 9.78 241.5 9.51 272 10.71 10.67 23.52 266 10.47 296.5 11.67
SDE030/5 264 10.39 294.5 11.59 287.5 11.32 318 12.52 12.70 28.00 312 12.28 342.5 13.48
SDE030/6 310 12.20 340.5 13.41 333.5 13.13 364 14.33 14.73 32.47 358 14.09 388.5 15.30
SDE030/7 356 14.02 386.5 15.22 379.5 14.94 410 16.14 16.76 36.95 404 15.91 434.5 17.11
SDE030/8 402 15.83 432.5 17.03 425.5 16.75 456 17.95 18.79 41.42 450 17.72 480.5 18.92
SDE030/9 448 17.64 478.5 18.84 471.5 18.56 502 19.76 20.82 45.90 496 19.53 526.5 20.73
SDE030/10 494 19.45 524.5 20.65 517.5 20.37 548 21.57 22.85 50.38 542 21.34 572.5 22.54

D1WWEB02E 5
SDE030-SDE060 valve general informations

Dimensional data ________________________________________________________________________________________

SDE060 directional valve


Dimensions are referred to directional valve with N1 type inlet section.

F 70
2.76
E 45
1.77

6.5
0.26
78.8
3.10

0.63
16

M8
A1 A2
T

228.2
8.98
1.42

3.54
31.5
2.76

1.24
P
36

34
70

B1 B2
0.049
1.25
0.039
1

10 27.5 40.5 46 38.5


0.39 1.08 1.59 1.81 1.52

type N inlet section type N1 inlet section (see drawing) type N2 inlet section
TYPE E F E F Weight E F
mm in mm in mm in mm in Kg lb mm in mm in
SDE060/1 84.5 3.33 115 4.53 106.5 4.19 137 5.12 5.08 11.20 137 5.12 167.5 6.59
SDE060/2 130.5 5.14 161 6.34 152.5 6.00 183 7.21 7.43 16.38 183 7.21 213.5 8.41
SDE060/3 176.5 6.95 207 8.15 198.5 7.82 229 9.02 9.78 21.56 229 9.02 259.5 10.22
SDE060/4 222.5 8.76 253 9.96 244.5 9.63 275 10.83 12.13 26.74 275 10.83 305.5 12.03
SDE060/5 268.5 10.57 299 11.77 290.5 11.44 321 12.64 14.48 31.92 321 12.64 351.5 13.84
SDE060/6 314.5 12.38 345 13.58 336.5 13.26 367 14.45 16.83 37.10 367 14.45 397.5 15.65
SDE060/7 360.5 14.19 391 15.39 382.5 15.06 413 16.26 19.18 42.28 413 16.26 443.5 17.46
SDE060/8 406.5 16.00 437 17.20 428.5 16.87 459 18.07 21.53 47.47 459 18.07 489.5 19.27
SDE060/9 452.5 17.81 483 19.02 474.5 18.68 505 19.88 23.88 52.65 505 19.88 535.5 21.08
SDE060/10 498.5 19.63 529 20.83 520.5 20.49 551 21.69 26.23 57.83 551 21.69 571.5 22.89

6 D1WWEB02E
valve general informations SDE030-SDE060
___________________________________________________________________________________________
Hydraulic circuit

Parallel circuit
Parallel circuit is composed using P or Q working section.
Outlet section can be with or without ports arrangement.

A B A B
M

Description example:
SDE060/2/AN1(TGW3-175)ELN/Q-18ES3/Q-18ES3/RF-12VDC

Series circuit: only for SDE060 valve


The series circuit is composed using alternately QS and Q working sections, both with 1S series spool.
The circuit starts always with QS working section.
Outlet section depends on total number of working section: if it is even, outlet section must be with P port open, if it is odd,
outlet section must be with T port open.

A B A B
M

T
T

Description example:
SDE060/2/AN1(TGW3-175)ELN/QS-1S8ES3SE/Q-1S8ES3SE/RP-12VDC

A B A B A B
M

P
T
T
Description example:
SDE060/3/AN1(TGW3-175)ELN/QS-1S8ES3SE/Q-1S8ES3SE/QS-1S8ES3SE/RT-12VDC

D1WWEB02E 7
SDE030-SDE060 valve general informations

Complete sections ordering codes __________________________________________________________________

SDE030/3/AN1(JNG3-120)ELN/P-18ESB3/P-18ESB3.PS3(DC3-100)/RF-......-12VDC
Nr. of working sections 1 2 2 4 3 5 6

6 3
2
8

SDE060/3/AN1(TGW3-120)ELN/P-18ES3/P-18ES3.BPEN3/RF-......-12VDC
Nr. of working sections 1 2 2 4 3 5 6

6
4

3
6 2
8

8 D1WWEB02E
valve general informations SDE030-SDE060
___________________________________________________________________
Complete sections ordering codes

1 Complete inlet section * 2 Complete working section * page 24


SDE030 inlet sections . . . . . . . . . . . . . . . . . . . . . . . . .page 10 TYPE CODE DESCRIPTION
Type: AN Code: 5FIA103306 SDE030 sections: sections are arranged for flangeable valve blocks
Description: Without valves, ports P and T open Q-18ES3B-WC Y63S303001C Parallel circuit, type 1 double acting
Type: ANP Code: 5FIA103302 spool
Description: As type AN, port P open and T plugged Q-28ES3B-WC Y63S303002C Parallel circuit, type 2 double acting
Type: ANT Code: 5FIA103302 spool
Description: As type AN, port P plugged and T open SDE060 sections: sections are arranged for flangeable valve blocks
Type: ANS Code: 5FIA103303 Q-18ES3-WC Y63S603001C Parallel circuit, type 1 double acting
Description: As type AN, ports P and T open spool
Type: AN1(JNG3-120)ELN-WC Code: Y61S303000 Q-28ES3-WC Y63S603002C Parallel circuit, type 2 double acting
Description: With pressure relief valve and solenoid operated spool
unloading valve, ports P and T open QS-1S8ES3SE-WC Y63S603003C Series circuit, type 1S double acting
Type: AN1P(JNG3-120)ELN-WC Code: Y61S303002 series spool
Description: As type AN1, port P open and T plugged Q-1S8ES3SE-WC Y63S603005C Parallel circuit, type 1S double
Type: AN2/PPXN1(JNG3-120)ELN-WC Code: Y61S303001 acting series spool: placed after
Description: With pressure relief valve, solenoid operated unloading QS series section only
valve and pressure compensated flow control valve, ports P and T
open 3 Complete outlet section* page 37
Type: AN2P/PPXN1(JNG3-120)ELN-WC Code: Y61S303005
Description: As type AN2, port P open and T plugged TYPE CODE DESCRIPTION
DE060 inlet sections . . . . . . . . . . . . . . . . . . . . . . . . . .page 15 RF 3FIA203000 Without ports (SDE030 and SDE060)
Type: AN Code: 5FIA103103 SDE030 sections
Description: Without valves, ports P and T open RS 619301200 With ports P and T plugged
Type: ANP Code: 5FIA103304 RP 619301100 With port P open and T plugged
Description: As type AN, port P open and T plugged RT 619301000 With port T open and P plugged
Type: ANT Code: 5FIA103304 SDE060 sections
Description: As type AN, port P plugged and T open RS 619303200 With ports P and T plugged
Type: ANS Code: 5FIA103305 RP 619303100 With port P open and T plugged
Description: As type AN, ports P and T open RT 619303000 With port T open and P plugged
Type: AN1(TGW3-175)ELN-WC Code: Y61S603000
Description: With pressure relief valve and solenoid operated 4 Complete flangeable valve block
unloading valve Antishock valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 32
Type: AN1P(TGW3-175)ELN-WC Code: Y61S603003 Check valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 33
Description: As type AN1, port P open and T plugged Solenoid operated check valves (without coils) . . . . .page 34
Type: AN2/PPXN1(TGW3-175)ELN-WC Code: Y61S603001 Single counterbalance valves . . . . . . . . . . . . . . . . . . .page 36
Description: With pressure relief valve, solenoid operated unloading Double counterbalance valves . . . . . . . . . . . . . . . . . . .page 36
valve and pressure compensated flow control valve, ports P and T
open
5 Valve threading
Type: AN2P/PPXN1(TGW3-175)ELN-WC Code: Y61S603006
Description: As type AN2, port P open and T plugged Specify threading always when it is different from BSP standard (see
SDE030-SDE060 special inlet sections . . . . . . . . . . . .page 20 page 4).
Type: AN6-EEXL1(VMP02TR-220)-SB10RC(C3)-WC
Code: Y61S303006 6 Coils page 38
Description: With pressure relief valve and flow control valve, for
Coils voltage specification; for list of available coils see pages of
Open Center circuit, compensator with 10 bar (145 psi) stand-by
related sections
Type: AN7-EEXN1(VMP02TR-200)-SB10RCV(C3)-WC
Code: Y61S303007
Description: As previous, for Open and Closed Center circuits, 7 Fixing bracket page 41
compensator with adjustable stand-by from 0 to 10 bar (0 to 145 psi) TYPE CODE DESCRIPTION
stand-by STAF 5STA148065 Brackets with fixing screws

8 Assembling kit
CODICE DESCRIZIONE CODICE DESCRIZIONE
5TIR108099 For 1 section valve 5TIR108329 For 6 sections valve
5TIR108144 For 2 sections valve 5TIR108375 For 7 sections valve
5TIR108191 For 3 sections valve 5TIR108420 For 8 sections valve
5TIR108236 For 4 sections valve 5TIR108466 For 9 sections valve
5TIR108282 For 5 sections valve 5TIR108512 For 10 sections valve

NOTE (*) – Codes are referred to BSP thread.

D1WWEB02E 9
SDE030-SDE060 inlet section

SDE030 inlet section parts ordering codes _______________________________________________________

Valve setting (bar)

SDE030 / AN - ...... SDE030 / AN1 (JNG3-120) ELN - WC - ......


1 5 1 2 3 Without 5
coil

1
1
2 6
3

Valve setting (bar)

SDE030 / AN2 / PPXN1 (JNG3-120) ELN - WC - ......


Without
1 4 2 3 coil
5

4
6
1

6
3
2

1 Inlet section body kit * page 11 3 Solenoid operated unloading valve page 13
TYPE CODE DESCRIPTION TYPE CODE DESCRIPTION
AN 5FIA103306 Without valves ELN 0EC08002031 Without emergency actuation
ANP 5FIA103302 As type AN, port P open and T plugged ELV 0EC08002034 With screw type emergency actuation
ANT 5FIA103302 As type AN, port P plugged and T open ELP 0EC08002033 With push-button emergency actuation
ANS 5FIA103303 As type AN, ports P and T plugged ELT 0EC08002035 With “twist & push” emergency actuation
AN1 5FIA103300 With pressure relief valve and unloading LT 3XTP3533700 Unloading valve blanking plug
valve arrangement, ports P and T open
AN2 5FIA103309 As AN2 with press. compensated flow control 4 Press. comp. flow control valve page 14
valve arrangement, ports P and T open
TYPE CODE DESCRIPTION
LT 3XTP3545700 Valve blanking plug
2 Main relief valve page 13 Manual operated
Valves standard setting is referred to 10 l/min (2.6 US gpm) flow, PPAL1 0PP10002000 Hand-wheel setting type
considering the valve mounted on inlet section. PPAV1 0PP10002005 Screw setting type
TYPE CODE DESCRIPTION Solenoid operated
(JNG2-63) 5KIT105512 Range 40-63 bar (580-900 psi) PPXN1 0PP10002031 Without emergency actuation
std setting 63 bar (900 psi) PPXV1 0PP10002033 With screw type emergency actuation
(JNG3-120) 5KIT105513 Range 50-200 bar (725-2900 psi) PPXL1 0PP10002035 With hand-wheel emergency actuation
std setting 120 bar (1750 psi)
(JNG4-220) 5KIT105514 Range 160-315 bar (2300-4600 psi) 5 Section threading
std setting 220 bar (3200 psi)
(JNH2-63) 5KIT105517 As type JNG2, set and locked Specify threading always when it is different from BSP standard (see
(JNH3-120) 5KIT105516 As type JNG3, set and locked page 4).
(JNH4-220) 5KIT105515 As type JNG4, set and locked
(JNZT2-63) 5KIT105562 As type JNG2, anti-tampering type 6 Optional coils page 38
(JNZT3-120) 5KIT105563 As type JNG3, anti-tampering type For list of available coils see pages of related sections.
(JNZT4-220) 5KIT105564 As type JNG4, anti-tampering type
SV XTAP623282 Relief valve blanking plug
NOTE (*) – Codes are referred to BSP thread.

10 D1WWEB02E
inlet section SDE030-SDE060
_____________________________________________________
SDE030 inlet section dimensions and circuit

AN inlet section

Configuration with ports P and T open

Hydraulic circuit
0.39

18 34
10

0.71 1.34 AN config. ANP config. ANT config. ANS config.


Ports P and T Port P open Port P plugged Ports P and T
open and T plugged and T open plugged

M8 - deep 10
M8 - deep 0.39 n.2 holes M M M M

M
2.76
70

36.5
1.44

P P P P
70
2.76 T T T
T
T
28.5
1.12

1.30
33

14 41
14.25
0.56

0.55 1.61

AN1 inlet section

Hydraulic circuit
Configuration with ports P and T open
AN configuration
M8 - deep 10 Ports P and T open
0.39

18 34
10

M8 - deep 0.39 n.2 holes


0.71 1.34 M
0.91
23

P
1
2
2.76
70

M T
48.5
1.91
38.5
1.52

19.5
0.77

70 66.5 AN1P configuration


2.76 2.62 Port P open and T plugged
182.5
7.19 M

P
P
T
2.05
52

36.5
1.44

33.5
1.32
14.5

14.5
0.57

0.57

28.5 28
1.12 1.10

Legenda T
1: Pressure relief valve
2: Solenoid operated unloading valve

D1WWEB02E 11
SDE030-SDE060 inlet section

SDE030 inlet section dimensions and circuit ____________________________________________________

AN2 inlet section

Configuration with ports P and T open


18 34

0.39
10
0.71 1.34
M8 - deep 10
n.2 holes
M8 - deep 0.39

1
Legenda
1: Pressure relief valve
3 2
2: Solenoid operated unloading valve
3: Pressure compensated flow control valve

M
3.23
82

2.72

2.52
61.5
69

2.42
64
21.5
0.85

56
2.20
70 66.5
2.76 2.62
232.5
9.15

T
P
76.5
3.01

3.19
81
1.77
1.77

45
45

28.5
1.12
20.5
0.81

16 40.5
0.63 1.59

Hydraulic circuit

AN2 configuration AN2P configuration


Ports P and T open Port P open and T plugged

M M

P P

T T

12 D1WWEB02E
inlet section SDE030-SDE060
__________________________________________________________________________
SDE030 inlet section options

Pressure relief valve


Setting types Setting range: type JNG2
0 1 2 3 4 5 6 7 (US gpm)
JG 400
X Legenda (bar)
(psi)
Y JG: screw setting type
5000
300
X = allen wrench 4 4000

Pressure
Y = wrench 13 - 24 Nm (17.7 lbft)
45,5 JH: valve set and locked 200 3000
1.79 (cap code 3COP117260) 2000
JH JZT: with anti-tampering cap 100 max. setting
(cap code 4COP120420) 1000
min. setting
0 0
0 5 10 15 20 25 30
59,5
Flow (l/min)
2.34

JZT

Setting range: type JNG3 Setting range: type JNG4


0 1 2 3 4 5 6 7 (US gpm) 0 1 2 3 4 5 6 7 (US gpm)
59 400 400
2.32 (psi) (psi)
(bar) (bar)
5000 5000
max. setting
300 300
4000 std. setting 4000
Pressure

Pressure
max. setting
200 3000 200 3000
min. setting
std. setting 2000 2000
100 100
1000 1000
min. setting
0 0 0 0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow (l/min) Flow (l/min)

Solenoid operated unloading valve

For AN1-AN2 inlet sections


Manual emergency actuation types

Pressure drop diagram


0 1.5 3 4.5 6 7.5 (US gpm)
ELN 2 10
(psi)
(bar)
8 120
1
Pressure

66,5 6 90
2.62
4 60

ELP ELV ELT


2 30

0 0
88 88 91
0 5 10 15 20 25 30
3.46 3.46 3.58
Flow (l/min)
2 2 2

1 1 1

Legenda Features
ELN: without amergency actuation Max. flow . . . . . . . . . . . . . . . . : 40 l/min (10.6 US gpm)
ELP: push-button type emergency actuation Max. pressure . . . . . . . . . . . . . : 380 bar (5500 psi)
ELV: screw type emergency actuation Internal leakage . . . . . . . . . . . : 0.25 cm3/min @ 210 bar
ELT: “push&twist” type emergency actuation (0.015 in3/min @ 3050 psi)
For coil features and options see coil BER at page 39

D1WWEB02E 13
SDE030-SDE060 inlet section

SDE030 inlet section options _________________________________________________________________________

Pressure compensated flow control valve

For AN2 inlet section


Manual operated Solenoid operated
Flow regulation diagram

40
(l/min) 10
(US gpm)
PPAV1 30 8

2 3 X 2 3 PPXN1
Y 6

Flow
20
4
1 1
41,5 10
2
1.63 96
3.78
PPAL1 X 0 0
2 3 Y 0 20 40 60 80 100 (%)
2 3 PPXV1 Valve operation
(A@12VDC)
1 0 0.25 0.50 0.75 1.00 1.25
1
45 110 0.63
1.77 4.33 0 0.10 0.20 0.30 0.40 0.50 0.60 (A@12VDC)
Coil current
2 3 PPXL1

1
Flow vs. Pressure diagram
143,5 0 800 1600 2400 3200 4000 (psi)
5.65 40
Legenda (l/min) on P2 line 10
PPAV1: screw setting type on P3 line (US gpm)
X, Y = wrench 10 - 6,6 Nm (4.9 lbft) 30 8

PPAL1: hand-wheel setting type


Flow

6
PPXN1: without emergency actuation 20
PPXV1: screw type emergency actuation 4
X = allen wrench 4 10
Y = wrench 8 - 15 Nm (11 lbft) 2
PPXL1: hand-wheel emergency actuation
0 0
0 50 100 150 200 250 300 (bar)
Pressure
Features
Max. inlet flow . . . . . . . . . . . .:
50 l/min (13.2 US gpm)
Max. regulated flow . . . . . . . . .:
30 l/min (7.9 US gpm)
Inlet flow (PPX types) . . . . . .
regulated flow +5% .:
Max. pressure . . . . . . . .350 bar (5100 psi) - PPA types
. . . . .:
315 bar (4600 psi) - PPX types
Internal leakage (PPX types) . .: 150 cm3/min @ 210 bar
(9.1 in3/min @ 3050 psi)
For coil features and options see coil BQP19 at page 39

14 D1WWEB02E
inlet section SDE030-SDE060
________________________________________________________
SDE060 inlet section parts ordering codes

Valve setting (bar)

SDE060 / AN - ...... SDE060 / AN1 (TGW3-175) ELN - WC - ......


1 5 1 2 3 Without 5
coil

1
3 6
2

Valve setting (bar)

SDE060 / AN2 / PPXN1 (TGW3-175) ELN - WC - ......


1 4 2 3 Without 5
coil

4
6
1

6
3
2

1 Inlet section body kit * page 16 3 Solenoid operated unloading valve page 18
TYPE CODE DESCRIPTION TYPE CODE DESCRIPTION
AN 5FIA103103 Without valves, ports P and T open ELN 0EC10002012 Without emergency override
ANP 5FIA103304 As type AN, port P open and T plugged ELV 0EC10002015 With screw type emergency override
ANT 5FIA103304 As type AN, port P plugged and T open ELP 0EC10002014 With push-button emergency override
ANS 5FIA103305 As type AN, ports P and T plugged ELT 0EC10002016 With “twist & push” emergency override
AN1 5FIA103307 With pressure relief valve and LT 3XTP3544200 Unloading valve blanking plug
unloading valve arrangement
AN2 5FIA103310 As previous with pressure compensated 4 Press. comp. flow control valve page 19
flow control valve arrangement
TYPE CODE DESCRIPTION
LT 3XTP3558200 Flow control valve blanking plug
2 Main relief valve page 18 Manual operated
Valves standard setting is referred to 5 l/min (1.3 US gpm) flow. PPAL1 0PP12002000 Hand-wheel setting type
TYPE CODE DESCRIPTION PPAV1 0PP12002004 Screw setting type
(TGW2-80) 0MC10002023 Range 10-120 bar (145-1750 psi) Solenoid operated
std setting 80 bar (1160 psi) PPXN1 0PP12002037 Without emergency actuation
(TGW3-175) 0MC10002024 Range 40-200 bar (580-2900 psi) PPXV1 0PP12002039 With screw type emergency actuation
std setting 175 bar (2550 psi) PPXL1 0PP12002041 With hand-wheel emergency actuation
(TGW4-250) 0MC10002025 Range 200-350 bar (2900-5100 psi)
std setting 250 bar (3600 psi) 5 Section threading
SV XTAP526360 Relief valve blanking plug
Specify threading always when it is different from BSP standard (see
page 4).

6 Optional coils page 38


NOTE (*) – Codes are referred to UN-UNF thread. For list of available coils see pages of related sections.

D1WWEB02E 15
SDE030-SDE060 inlet section

SDE060 inlet section dimensions and circuit ____________________________________________________

AN inlet section

Configuration with ports P and T open

23 34
Hydraulic circuit
0.39
10

0.91 1.34
AN config. ANP config. ANT config. ANS config.
Ports P and T Port P open Port P plugged Ports P and T
open and T plugged and T open plugged

M8 - deep 10
n.2 holes
M8 - deep 0.39
M M M M

M
2.76
70

36.5
1.44

80 P P P P
3.15
T T T
T P
T
1.30

37.5
33

1.48

16.5 46
16.5
0.65

0.65 1.81

AN1 inlet section

Hydraulic circuit
Configuration with ports P and T open
AN1 configuration
18.5 34 M8 - deep 10
0.39

Ports P and T open


10

n.2 holes
0.73 1.34 M8 - deep 0.39
M
25.5
1.00

P
1
2
2.76
70

T
M
42.5
1.67
1.54
39

0.55
14

70 66.4
AN1P configuration
2.76 2.61 Port P open and T plugged
180.3
M
7.10

P P
2.17
55

39.5

37.5
1.56

1.48
16,5

T
0.65

0.63
16

16.5 37
0.65 1.46
T
Legenda
1: Pressure relief valve
2: Solenoid operated unloading valve

16 D1WWEB02E
inlet section SDE030-SDE060
_____________________________________________________
SDE060 inlet section dimensions and circuit

AN2 inlet section

Configuration with ports P and T open


32 34

0.39
10
1.26 1.34
1

2 Legenda
M8 - deep 10
M8 - deep 0.39 1: Pressure relief valve
n.2 holes 2: Solenoid operated unloading valve
3: Pressure compensated flow control valve
3

M
3.15
80

61.5
2.42

61.5
2.42
0.91
23

73.5
2.89
90 66.4
3.54 2.61
253.3
9.97

T
85.5
3.37

3.54
90
50.5
1.99

1.97
50

P
1.22
31
0.63
16

16.5 57.5
0.65 2.26

Hydraulic circuit

AN2 configuration AN2P configuration


Ports P and T open Port P open and T plugged

M M

P P

T T

D1WWEB02E 17
SDE030-SDE060 inlet section

SDE060 inlet section options _________________________________________________________________________

Main relief valve

Tipo di regolazione
Setting range: type TGW2 Setting range: type TGW3
TGW 0 3 6 9 12 15 (US gpm) 0 3 6 9 12 15 (US gpm)
X Y 400 400
(psi) (psi)
(bar) (bar)
5000 5000
300 300
4000 4000
Pressure

Pressure
43 max. setting
1.69 200 3000 200 3000
max. setting std. setting
2000 2000
TZW 100 std. setting 100
1000 1000
min. setting min. setting
0 0 0 0
0 10 20 30 40 50 60(l/min) 0 10 20 30 40 50 60(l/min)
51 Flow Flow
2.01

Legenda Setting range: type TGW4


TGW: screw setting type
0 3 6 9 12 15 (US gpm)
X = allen wrench 5 400 (psi)
Y = wrench 19 - 20 Nm (14.8 lbft) (bar)
max. setting 5000
TZW: with anti-tampering cap
300 std. setting
(cap code 4COP126300, nr. 2 pcs) 4000
Pressure
min. setting
200 3000

2000
100
1000

0 0
0 10 20 30 40 50 60(l/min)
Flow

Unloading valve

For AN1-AN2 inlet sections


Manual emergency actuation types
Pressure drop diagram
0 3 6 9 12 15 (US gpm)
20
ELN 2 (psi)
(bar)
16 240
1
Pressure

12 180
66.5
2.62
8 120

4 60
ELP ELV ELT
0 0
0 10 20 30 40 50 60 (l/min)
Flow
89.5 89.5 92
3.52 3.52 3.62
2 2 2

1 1 1

Legenda Features
ELN: without amergency actuation Max. flow . . . . . . . . . . . . . . . . : 40 l/min (10.6 US gpm)
ELP: push-button type emergency actuation Max. pressure . . . . . . . . . . . . . : 380 bar (5500 psi)
ELV: screw type emergency actuation Internal leakage . . . . . . . . . . . : 0.25 cm3/min @ 210 bar
ELT: “push&twist” type emergency actuation (0.015 in3/min @ 3050 psi)
For coil features and options see coil BER at page 39

18 D1WWEB02E
working section SDE030-SDE060
__________________________________________________________________________
SDE060 inlet section options

Pressure compensated flow control valve

For AN2 inlet section


Manual operated Solenoid operated Flow regulation diagram

60
(l/min) 15
(US gpm)
PPAV1 45 12

Portata
2 3
Y 2 3 PPXN1 9
30
6
1 1 15
46 3
1.81 97
0 0
PPAL1 X
3.82
0 20 40 60 80 100 (%)
2 3
2 3 Y PPXV1 Valve operation
(A@12VDC)
0 0.25 0.50 0.75 1.00 1.25
1
1 0.63
45 111 0 0.10 0.20 0.30 0.40 0.50 0.60 (A@12VDC)
1.77 4.37
Coil current
2 3 PPXL

Flow vs. Pressure diagram


1
144,5 0 800 1600 2400 3200 4000 (psi)
5.69 60
(l/min) 15
Legenda (US gpm)
PPAV1: screw setting type 45 12
X, Y = wrench 10 - 6.6 Nm (4.9 lbft)
PPAL1: hand-wheel setting type
Flow

9
30
PPXN1: without emergency actuation
6
PPXV1: screw type emergency actuation
15
X = allen wrench 4 on P2 line 3
Y = wrench 8 - 15 Nm (11 lbft) on P3 line
PPXL1: hand-wheel emergency actuation 0 0
0 50 100 150 200 250 300 (bar)
Pressure
Features
Max. inlet flow . . . . . . . . . . . . : 90 l/min (23.8 US gpm)
Max. regulated flow . . . . . . . . . : 50 l/min (13.2 US gpm) - PPA types
60 l/min (16 US gpm) - PPX types
Inlet flow (PPX types) . . . . . . .: regulated flow +15%
Max. pressure . . . . . . . . . . . . . : 350 bar (5100 psi) - PPA types
315 bar (4600 psi) - PPX types
Internal leakage (PPX types) . .: 250 cm3/min a 210 bar
(15.3 in3/min @ 3050 psi)
For coil features and options see coil BQP19 at page 39.

D1WWEB02E 19
SDE030-SDE060 inlet section

SDE030-SDE060 special inlet section parts ordering codes _________________________________

Valve setting (bar)

SDE030 / AN6 / EEXN1 (VMP02TS-200) SB10RC(C3) - WC - ......


Without
1 3 2 4 coil
5

6
3
2

1 Inlet section body kit * page 21 4 Compensator kit page 23


TYPE CODE DESCRIPTION TYPE CODE DESCRIPTION
AN6 5FIA103316 For Open Center, relief valve and flow control SB10RCV(C3) 5KT6200227 With 10 bar (145 psi) stand-by, hand-
valves arrangement, compensator, LS port wheel actuation for Open Center to
plugged Closed Center switching
AN7 5FIA103317 As type AN6, for Closed Center, LS port open SB10RC(C3) 5KT6200222 With 10 bar (145 psi) stand-by,
for Open Center circuit
2 Main relief valve page 22 CL X451810000 Compensator blanking plug, for
Closed Center circuit
Valves standard setting is referred to 1 l/min (0.26 US gpm) flow and
it’s referred for valve mounted on inlet scetion.
TYPE CODE DESCRIPTION
5 Section threading
(VMP02TV-50) 1100000100 Range 5-80 bar (73-1160 psi) Specify threading always when it is different from BSP standard (see
std setting 50 bar (725 psi) page 4).
(VMP02TS-150) 1100000101 Range 50-220 bar (725-3200 psi)
std setting 150 bar (2200 psi) 6 Optional coils page 38
(VMP02TR-250) 1100000102 Range 180-350 bar (2600-5100 psi)
std setting 250 bar (3600 psi) For list of available coils see pages of related sections.

3 Solenoid operated unloading valve page 22


TYPE CODE DESCRIPTION
EEXN1 0EE10002009 Solenoid operation, without emergency
actuation
EEXL1 0EE10002008 Solenoid operation, hand-wheel
emergency actuation NOTE (*) – Codes are referred to BSP thread.

20 D1WWEB02E
inlet section SDE030-SDE060
_______________________________
SDE030-SDE060 special inlet section dimensions and circuit

AN6-AN7 inlet section

AN6 configuration: for Open center circuit


70
2.76
18 34
0.71 1.34

Legenda

0.39
1: Pressure relief valve

10

2.72
69
2: Pressure flow control valve
3: Compensator
M8 - deep 10
n.2 holes
M8 - deep 0.39
Ports thread
3 P, T: G 3/8
LS, M: G 1/4

T 1
122.2
4.81

3.74
95
2
P
2.40

2.28
61

58

LS

1.38
35
0.91

0.91

0.91
M
23

23

23
33.5 17.5 20.5 20
1.32 0.69 0.81 0.79
166.5
6.56
48.5 21.5 4.5
1.91 0.85 0.18
33.5
1.32

0.94
24
16.5
0.65

0.18
4.5

Hydraulic circuit

AN6 configuration AN7 configuration


for Open Center circuit for Closed Center circuit

M M

P P

LS LS

T T

D1WWEB02E 21
SDE030-SDE060 inlet section

SDE030-SDE060 special inlet section options ___________________________________________________

Main relef valve

36
Setting range: type VMP02TV
1.42
0 3 6 9 12 15 (US gpm)
400 (psi)
Y (bar)
5000
300
4000

Pressure
X
200 3000

2000
max. setting
100
1000
std. setting min. setting
X = wrench 10 0 0
Y = wrench 10 - 6.6 Nm (4.9 lbft) 0 10 20 30 40 50 60
Flow (l/min)

Setting range: type VMP02TS Setting range: type VMP02TR


0 3 6 9 12 15 (US gpm) 0 3 6 9 12 15 (US gpm)
400 (psi) 400
(bar) max. setting (psi)
(bar)
5000 5000
300 300
4000 std. setting 4000
Pressure

Pressure
max. setting
min. setting
200 3000
200 3000

std. setting 2000 2000


100 100
min. setting 1000 1000

0 0 0 0
0 10 20 30 40 50 60 0 10 20 30 40 50 60
Flow (l/min) Flow (l/min)

Flow control valve


Curves are measured using the standard compensator mounted on section, with 10 bar (145 psi) stand-by.

Flow regulation diagram Flow vs. Pressure diagram


0 500 1000 1500 2000 2500 (psi)
50 40
(l/min) 12
(l/min)
10
(US gpm) (US gpm)
40
EEXN1 10 30 8

30 8
Flow

Flow

6
6 20
20
4
4
10
92 10 2
2
3.62
2
0 0 0 0
0 20 40 60 80 100 (%) 0 40 80 120 160 200 (bar)
Valve operation Pressure
1
0 0.25 0.50 0.75 1.00 1.25 (A@12VDC)
EEXL1
0.63
0 0.10 0.20 0.30 0.40 0.50 0.60 (A@12VDC)
Coil current
121.5
4.78
2

Features
1 Max. flow . . . . . . . . . . . . . . . . : 40 l/min (10.6 US gpm)
Max. pressure . . . . . . . . . . . . . : 300 bar (5500 psi)
Legenda Internal leakages . . . . . . . . . .: 0.25 cm3/min @ 210 bar
EEXN1: without emergency actuation (0.015 in3/min @ 3050 psi)
EEXL1: hand-wheel emergency actuation For coil features and options see coil BQP19 at page 39.

22 D1WWEB02E
inlet section SDE030-SDE060
____________________________________________________
SDE030-SDE060 special inlet section options

Compensator kit

SB10RCV(C3)

Legenda
SB10RC(C3) CL

3.27
83
SB10RC(C3): compensator with 10 bar (145 psi) stand-by, for Open
Center circuit
27.2
1.07

CL: compensator blanking plug, for Closed Center circuit


19.5
0.77

SB10RCV(C3): compensator with 10 bar (145 psi) stand-by, hand-


wheel actuation for Open Center to Closed Center circuit switching
c.c. c.a.

D1WWEB02E 23
SDE030-SDE060 working section

SDE030-SDE060 working section parts ordering codes ______________________________________

Valve setting (bar)

SDE030 / P - 1 8ES3B . P3(100) - WC - ......


1 2 3 4 Without 5
coil

3
6

1
3
2 3

Valve setting (bar)

SDE060 / P - 1 8ES3 . P3(100) - WC - ......


1 2 3 4 Without 5
coil

3
6

1
3
2 3

24 D1WWEB02E
working section SDE030-SDE060
______________________________________
SDE030-SDE060 working section parts ordering codes

1 Working section body kit * page 26 3 Control kit


TYPE CODE DESCRIPTION TYPE CODE DESCRIPTION
Sections with standard threads: G3/8 For SDE030 working section . . . . . . . . . . . . . . . . . . . .page 30
Q 5EL1033000 Parallel type, with arrangement for 8ES1B 5CAN08E114C ON/OFF solenoid control on port A
upper flangeable valve block 8ES2B 5CAN08E114C ON/OFF solenoid control on port B
QS 5EL2033000 As type Q, for series circuit: need spool 8ES3B 5CAN08E115C ON/OFF solenoid control on both ports
type 1S. Only for SDE060 valve 8ES3CBLHC 5CAN08E215C ON/OFF solenoid control on both ports
Q(8) 5EL1033500 As type Q, for regenerative circuit on with emergency lever operation
port A: need spool type 8 For SDE060 working section . . . . . . . . . . . . . . . . . . . .page 31
P 5EL1033010 As type Q, with arrangement for 8ES1 5CAN08E110C ON/OFF solenoid control on port A
secondary relief valve 8ES2 5CAN08E110C ON/OFF solenoid control on port B
Sections with increased threads: G1/2 8ES3 5CAN08E111C ON/OFF solenoid control on both ports
QNF-BSP12 5EL1034010 Parallel type, without arrangement for 8ES3LHC 5CAN08E211C ON/OFF solenoid control on both ports
upper flangeable valve block with emergency lever operation
QSNF-BSP12 5EL1034011 As type Q, for series circuit: need spool 8ES3SE 5CAN08E116C ON/OFF solenoid control on both ports:
type 1S. Only for SDE060 valve dedicated for spool type 1S
QNF(8)-BSP12 5EL1034500 As type Q, for regenerative circuit on
port A: needs spool type 8 4 Secondary port valves page 27
PNF-BSP12 5EL1034000 As type Q, with arrangement for
secondary port valves Relief valves: standard setting is referred to 10 l/min (2.6 US gpm)
flow.
TYPE CODE DESCRIPTION
2 Spool page 28 P(G3-100) 5KIT060000 From 50 to 200 bar (725 to 2900 psi),
TYPE CODE DESCRIPTION standard setting 100 bar (1450 psi)
For ON/OFF solenoid control P(G4-200) 5KIT060001 From 200 to 315 bar (2900 to 4600 psi),
1 3CU9010100 Double acting, A and B closed in neutral standard setting 200 bar (2900 psi)
position P3T 5KIT060100 A and B ports valve blanking plugs
2 3CU9025100 Double acting, A and B connected to
tank in neutral position 5 Section threading
2H 3CU9025225 Double acting, A and B partially
connected to tank in neutral position Specify threading always when it is different from BSP standard (see
1S 3CU9010101 Double acting, for series circuit: needs page 4).
control type 8ES3SE
8 3CU9080100 Double acting, for regenerative circuit: 6 Optional coils page 38
needs section type Q8 For list of available coils see pages of related sections
For ON/OFF solenoid control with manual lever operation
1LH 3CU9010200 As type 1
2LH 3CU9020200 As type 2
2HLH 3CU9020210 As type 2H
8LH 3CU9080110 As type 8

NOTE (*) – Codes are referred to BSP thread.

D1WWEB02E 25
SDE030-SDE060 working section

SDE030-SDE060 working section dimensions and circuit ___________________________________

Working section type Q

Type Q: parallel circuit Type Q8: regenerative circuit


(with spool type 1) (need spool type 8)
A B A B

62.5
2.46
27.5
1.08
Valve fixing plan
68.2

0.30
7.5
2.69

Standard port thread: G3/8


with arrangement for valve blocks
6.1 56
0.24 2.20

A B
1.34

1.81
34

46
0.91
23

Type QS: series circuit


18.4 31.5
(need spool type 1S)
0.24
6

0.72 1.24
A B

Increased port thread: G1/2


without arrangement for valve blocks (NF type)

A B
1.81
46
0.91
23

17.6 33
0.69 1.30

Flow trough pressure drop Flow trough pressure drop


(parallel and regenerative circuits) (QS series section with 1S spool)
0 3 6 9 12 15 (US gpm) 0 3 6 9 12 15 (US gpm)
1.5 20
(psi)
(bar) 20 (bar)
(psi) 240
1.2 16
15
Pressure
Pressure

0.9 12 180

10
0.6 8 120

5 4
0.3 60

0 0 0 0
0 10 20 30 40 50 60(l/min) 0 10 20 30 40 50 60(l/min)
Flow Flow

26 D1WWEB02E
working section SDE030-SDE060
____________________________________
SDE030-SDE060 working section dimensions and circuit

Working section type P


With arrangement for secondary port valves.
Type P section is available also with increased port threads (G1/2): see type Q section for dimensional data.
0.67

Type P: parallel circuit


17

(with spool type 1)

1.81
A B

46
0.91
23
24,5 19
14.5
0.57

0.96 0.75

62.5
2.46
27.5
1.08

Valve fixing plan


0.30
7.5

68.2
2.69

__________________________________________________________________________________
Secondary port valves

Relief valves

Type G Setting range: type G3


Screw adjustment
0 0.3 0.6 0.9 1.2 1.5 (US gpm)
400 (psi)
(bar)
5000
300
4000
Pressure

max. setting
200 3000

2000
26.5
1.04

100
1000
min. setting
0 0
0 1 2 3 4 5 6 (l/min)
Flow
Type H
Valve set and locked
Setting range: type G4
0 0.3 0.6 0.9 1.2 1.5 (US gpm)
400 (psi)
(bar)
5000
max. setting
300
4000
Pressure

200 3000

min. setting 2000


100
1000

0 0
0 1 2 3 4 5 6 (l/min)
Flow

D1WWEB02E 27
SDE030-SDE060 working section

Spools _______________________________________________________________________________________________________

Type 1

P⇒port - port⇒T pressure drops


1 0 2 (curves are matched)
A B 0 3 6 9 12 15 (US gpm)
20
(psi)
(bar)
16 240

Pressure
12 180
P T
8 120

Spool stroke
position 1: + 3 mm (+ 0.12 in) 4 60

position 2: - 3 mm (- 0.12 in)


0 0
0 10 20 30 40 50 60(l/min)
Flow

Type 2

P⇒port - port⇒T pressure drops


1 0 2 (curves are matched)
A B 0 3 6 9 12 15 (US gpm)
20
(psi)
(bar)
16 240
Pressure

12 180
P T
8 120
Spool stroke
position 1: + 3 mm (+ 0.12 in) 4 60

position 2: - 3 mm (- 0.12 in)


0 0
0 10 20 30 40 50 60(l/min)
Flow

Type 2H

P⇒port - port⇒T pressure drops


1 0 2 (curves are matched)
A B 0 3 6 9 12 15 (US gpm)
20
(psi)
(bar)
16 240
Pressure

12 180
P T
8 120
Spool stroke
position 1: + 3 mm (+ 0.12 in) 4 60

position 2: - 3 mm (- 0.12 in)


0 0
0 10 20 30 40 50 60(l/min)
Flow

28 D1WWEB02E
working section SDE030-SDE060
________________________________________________________________________________________________________
Spools

Type 1S

P⇒port - port⇒T pressure drops


1 0 2 (curves are matched)
A B 0 3 6 9 12 15 (US gpm)
40
(psi)
(bar)
480
30

Pressure
360
P T 20
240
Spool stroke 10
position 1: + 3 mm (+ 0.12 in) 120

position 2: - 3 mm (- 0.12 in)


0 0
0 10 20 30 40 50 60(l/min)
Flow

Type 8
Spool suitable for 30 l/min (8 US gpm) max. flow

1 0 2 P⇒port - port⇒T pressure drops


A B 0 1.5 3 4.5 6 7.5 (US gpm)
10
(psi)
(bar)
8 120
Pressure

6 90
P T P ⇒ A1
4 60
B1 ⇒ T
Spool stroke
position 1: + 3 mm (+ 0.12 in) 2 30
position 2: - 3 mm (- 0.12 in)
0 0
0 5 10 15 20 25 30 (l/min)
Flow

D1WWEB02E 29
SDE030-SDE060 working section

SDE030 spool control kit ______________________________________________________________________________

Types 8ES3B - 8ES1B - 8ES2B


When the section is configurated with flangeable valve block, the coils on control must be rotated 180°

8ES3B: double acting control kit 8ES1B: single acting on A control kit

76 6.4
76 76
2.99 0.25
2.99 2.99
220.2 150.6
8.67 5.93

Operating condition 8ES2B: single acting on B control kit


(stroke 3 mm - 0.12 in)
(bar) 0 1.5 3 4.5 6 7.5 (US gpm)
420 6000
(psi)
360 5000
300
4000
Pressure

240
3000
180
2000
120

60 1000 6,4 76
0.25 2.99
0 0 150.6
0 5 10 15 20 25 30 (l/min) 5.93
Flow

Type 8ES3CBLHC
The control is not suitable for series circuit.
When the section is configurated with flangeable valve block, the control (whit coil) must be rotated 180°.
IMPORTANT: lever to be used only for emergency operation, not for continuative use.
18°
54’
2 18
°5
2 4’
10°12’
1
60

10
°

°1
4.69
119

2 ’

1: idle stroke angles


2: total operation angles

34.5
1.36
76 142.2
2.99 5.60
286.4
11.28
14.5
0.57

Control features
Max. back pressure on T . : 50 bar (725 psi)

30 D1WWEB02E
working section SDE030-SDE060
_______________________________________________________________________________
SDE060 spool control kit

Types 8ES3 - 8ES1 - 8ES2 - 8ES3SE


Note: when the section is configurated with flangeable valve block, the coils on control must be rotated 180°.

8ES3 - 8ES3SE: double acting control kit 8ES1: single acting on A control kit

80 80 80 7.9
3.15 3.15 3.15 0.31
228.2 156.1
8.98 6.15

Operating condition 8ES2: single acting on B control kit


(stroke 3 mm - 0.12 in)
(bar) 0 3 6 9 12 15 (US gpm)
420 6000
(psi)
360 5000
300
4000
Pressure

240
3000
180
2000 SDE060 with 8ES3 control kit;
120
parallel circuit
1000
60 SDE060 with 8ES3SE control kit; 7.9 80
series circuit 0.31 3.15
0 0
156.1
0 10 20 30 40 50 60 (l/min) 6.15
Flow

Type 8ES3LHC
The control is not suitable for series circuit.
When the section is configurated with flangeable valve block, the control (whit coil) must be rotated 180°.
IMPORTANT: lever to be used only for emergency operation, not for continuative use.
18°
54’
2 18
°5
2 4’
10°12’
1
60

10
°

°1
4.69
119

2 ’

1: idle stroke angles


2: total operation angles

34.5
1.36
80 146.1
3.15 5.75
294.3
11.59
14.5
0.57

Control features
Max. back pressure on T . : 50 bar (725 psi)

D1WWEB02E 31
SDE030-SDE060 flangeable valve blocks

Antishock valves _________________________________________________________________________________________

Dimensional data and circuit


On/off solenoid control 8ES (with or without lever operation) must be rotated 180°.

PS3 type: valves on both ports PS1 or PS2 types: valve on single port
(PS1 type is drawn: PS2 type has the valve mounted on the
opposite side and the same dimensions)

PS1 type

15.5
0.61
2.68
68

A B

43.5
1.71
36.5
1.44
15.5
0.61

A B

70 57.5 68
2.76 2.26 2.68
185 125.5
7.28 4.94
PS2 type
A B A B
A B
1.77

43.5
1.71
45

22.5
0.89

22.5
0.89
19.5 31 19.5 29
0.77 1.22 0.77 1.14
NOTE: for valve block assembly
direction refer to ports name

Ordering codes Antishock valve pressure drops


P⇒port - port⇒T
TYPE CODE DESCRIPTION (curves are matched)
Complete antishock valves
0 3 6 9 12 15 (US gpm)
PS1(DC3-160) 619001000 On ports A 10
PS2(DC3-160) 619001000 On port B (bar)
PS3(DC3) 619001100 On ports A and B 8 120

Part #1: Valve kit


Pressure

6 90
Valves standard setting is referred to 5 l/min (1.3 US gpm) flow,
considering the valve mounted on block.
4 60
(DC2-60) 1100520460 Range 20-80 bar (290-1150 psi)
std setting 60 bar (870 psi) 2 30
(DC3-160) 1100520408 Range 50-220 bar (725-3200 psi)
std setting 160 bar (2300 psi) 0 0
(DC4-280) 1100520414 Range 180-350 bar (2600-5100 psi) 0 10 20 30 40 50 60(l/min)
std setting 280 bar (4050 psi) Flow
PST XTAP623282 Valve blanking plug
Part #2: Block body kit
PS1-PS2 5COR245682 For single valve on port A or B
PS3 5COR245680 For valves on port A and B
Setting range
0 3 6 9 12 15 (US gpm)
400 (psi)
(bar)
5000
300
4000
2
Pressure

Control description
8ES3CBLHC180 200 3000

2000
100
1000
1
0 0
0 10 20 30 40 50 60 (l/min)
Flow

Valve type DC2


Valve type DC3
Control description
Valve type DC4
8ES3B180

32 D1WWEB02E
flangeable valve blocks SDE030-SDE060
_______________________________________________________________________________________________
Check valves

Dimensional data and circuit


On/off solenoid control 8ES (with or without lever operation) must be rotated 180°.

0.63
16
43.5
1.71

BP3 type BP1 type BP2 type

A B A B A B
14.5 94
0.57 3.70
123
4.84

A B
1.77
45

22.5
0.89

16 62
0.63 2.44

Ordering codes Check valve pressure drop


0 3 6 9 12 15 (US gpm)
TYPE CODE DESCRIPTION 40
Complete valve block (bar)
(psi)

BP1 619002000 Valve on port A 480


30
BP2 619002000 Valve on port B
P ⇒ port
Pressure

360
BP3 619002100 Valves on ports A and B
Part #1: Valve kit 20
port ⇒ T 240
BP 1300020402 Check valve
TBP XTAP627260 Valve blanking plug 10
120
Part #2: Body kit and piston
5COR245892 Block body kit 0 0
3PIS214480 Piston 0 10 20 30 40 50 60(l/min)
Flow
1

Control description
8ES3B180

Control description
8ES3CBLHC180

D1WWEB02E 33
SDE030-SDE060 flangeable valve blocks

Solenoid operated check valves _____________________________________________________________________

Dimensional data and circuit


On/off solenoid control 8ES (with or without lever operation) must be rotated 180°.

Type BPE(NC): normally closed circuit

BPEN3(NC) type

A B

43.5
1.71
95 62.8
0.63
16

3.74 2.47
220.6
8.69
BPEN

A B
1.77
45

22.5
0.89

BPEN1(NC) type BPEN2(NC) type


14 67 2 A B A B
0.55 2.64

1
BPEV BPEP BPEG

77.3 90.8 83.6


3.04 3.57 3.29
2 2 2

1 1 1

Type BPE(NA): normally open circuit

BPEN3(NA) type

A B
43.5
1.71

95 66.5
0.63
16

3.74 2.62
228
8.98
BPEN

A B
1.77
45

22.5
0.89

BPEN3(NA) type BPEN3(NA) type


14 67 2
A B A B
0.55 2.64

1
BPEV BPEP BPEG

88 88 91
3.46 3.46 3.58
2 2 2

1 1 1

34 D1WWEB02E
flangeable valve blocks SDE030-SDE060
_____________________________________________________________________
Solenoid operated check valves

Dimensional data and circuit

NA check valve pressure drop Ordering codes


P⇒port - port⇒T (curves are matched)
TYPE CODE DESCRIPTION
0 3 6 9 12 15 (US gpm)
40 Complete valve block, without coil
(psi)
(bar) BPEN1(NC)-WC Y64S363001 On ports A, NC circuit, without
480 manual emergency
30
BPEN2(NC)-WC Y64S363001 As previous, on port B
Pressure

360
BPEN3(NC)-WC Y64S363000 As previous, on ports A and B
20
Part #1: Valve kit
240
TBPE 3XTAP822150 Valve blanking plug
10
120
Normally closed circuit
BPEN(NC) 0EC08002032 Without manual emergency
0 0 BPEV(NC) 0EC08002037 With screw type emergency
0 10 20 30 40 50 60(l/min) BPEP(NC) 0EC08002036 With pull-button emergency
Flow BPET(NC) 0EC08002038 With “pull & twist” emergency
Normally open circuit
BPEN(NA) 0EC08002031 Without manual emergency
BPEV(NA) 0EC08002034 With screw type emergency
BPEP(NA) 0EC08002033 With push-button emergency
BPET(NA) 0EC08002035 With “push & twist” emergency
Part #2: Block body kit
BPE3 5COR245950 Block body kit
Part #3: Coil
Valves needs type BER coil, see page 38.

Control description
8ES3B180
Control description
8ES3CBLHC180

D1WWEB02E 35
SDE030-SDE060 flangeable valve blocks

Counterbalance valves _________________________________________________________________________________

Dimensional data and circuit


On/off solenoid control 8ES (with or without lever operation) must be rotated 180°.

Double acting valve Single acting valve

48.5
1.91

48.5
1.91
26.5
1.04

26.5
1.04
150 47 47 108
5.91 1.85 1.85 4.25
244 155
9.61 6.10

OVN OVN
A B A B
1.77

1.77
45

45
22.5

22.5
0.89

0.89
51 48 51 39
2.01 1.89 2.01 1.54

OVR OVR OVV

51.4 51.4 50
2.02 2.02 1.97

OVN301 type OVR301 type OVR101 type OVR101 type OVV101 type

A B A B A B A B A B

Ordering codes OVN201 type OVR201 type OVV201 type

TYPE CODE DESCRIPTION A B A B A B


Single counterbalance valves
OVN101 1515322100 On port A, load sensitive, pilot ratio = 4
OVN201 1515322100 As previous, on ports B
OVR101 1515422100 On port A, relief compens., pilot ratio = 4
OVR201 1515422100 As previous, on ports B
OVV101 1515522100 On port A, vented type, pilot ratio = 4
OVV201 1515522100 As previous, on port B
Double counterbalance valves
OVN301 1555222100 Load sensitive, pilot ratio = 4
OVR301 1555322100 Relief compensated, pilot ratio = 4
Counterbalance valves pressure drop
0 3 6 9 12 15 (US gpm)
40
(psi)
(bar)
960
30
Pressure

720
port ⇒ T
20
480
P ⇒ port

10
240
Control description Control description
8ES3B180 8ES3CBLHC180
0 0
0 10 20 30 40 50 60 (l/min)
Flow

36 D1WWEB02E
outlet section SDE030-SDE060
_____________________________________________________________________
SDE030-SDE060 outlet sections

Dimensional data and circuit

RF type: without ports RS - RP - RT types: with ports

for SDE030 for SDE060

0.22

0.22
5.5

5.5
18 34 18 34 18 34
0.39
10

0.71 1.34 0.71 1.34 0.71 1.34


25.5

25.5

25.5
1.00

1.00

1.00
0.39

0.39
10

10
M8 - deep 10 M8 - deep 10 M8 - deep 10
M8 - deep 0.39 M8 - deep 0.39 M8 - deep 0.39

P
P
2.76

2.76

2.76
T
70

27.5
70

70
0.67 1.08
1.02
26

17
70 70 35 18
0.55
14

2.76 2.76 1.38 0.71


70
2.76

Hydraulic circuit Hydraulic circuit


RS: P and T plugged RP: P open, T plugged RT: T open, P plugged

P P P
T T T

D1WWEB02E 37
SDE030-SDE060 accessories

Coils and connectors ___________________________________________________________________________________

Connectors
Application on Coil type Voltage Flying leads
Packard Packard
ISO4400 Deutsch DT AMP JPT (without
Weatherpack Metri-pack
connector)
10VDC 4SLE001000 - - - - -
4SLE001201(5)
4SLE001209(3-5)
4SLE001200 4SLE001203(5) 4SLE001210 4SLE001214
12VDC 4SLE001202(6) 4SLE001207
4SLE001217(3) 4SLE001211(3-5) (2) (2)

Solenoid 4SLE001216(3-6)
operated 4SLE001206(2)
unloading valve 4SLE002400 4SLE002401(5)
BER 24 VDC 4SLE002408(3) 4SLE0024007(3-5) 4SLE002403(5) - - 4SLE002404
Solenoid 4SLE302400(1) 4SLE002402(6)
operated check 4SLE004800
valve 48 VDC - - - - -
4SLE304800(1)
4SLE011000
110VDC - - - - -
4SLE311000(1)
4SLE022000
220VDC - - - - -
4SLE322000(1)
Pressure 12VDC 4SL5000126 4SL5000125(6) 4SL5000129(5) - - -
compensated
BQP19
flow control
valve 24VDC 4SL5000245 4SL5000244(6) 4SL5000248(5) - - -

10,5VDC 4SOL412011-C - - - - -
D12C 4SOL412013-C(6) 4SOL412014-C
12VDC 4SOL412012-C - - 4SOL412019-C
4SOL412112-C(2) (5)

(SDE030)
4SOL412026-C
24VDC 4SOL412024-C 4SOL412025-C(6) (5) - - -
Controls 4SOL515014-C 4SOL515019-C
12VDC 4SOL515012-C - - -
(3-6)
4SOL515020-C(3)
D15C 4SOL515016A-C
14VDC - - - - -
(SDE060) (5)

4SOL515025-C
24VDC 4SOL515024-C (3-6) - - - -

Notes: ( ) supply with AC and use only with rectifier connector - ( ) with flying leads - ( ) with bidirectional diode - ( ) with unidirectional diode
1 2 3 5

(5) integrated perpendicular type - (6) integrated parallel type

38 D1WWEB02E
accessories SDE030-SDE060
____________________________________________________________________________________
Coils and connectors

BER type

ISO4400 connector DEUTSCH DT04 connector Features


(perpendicular type) Nominal voltage tolerance : ±10%
Power rating . . . . . . . . . . : 19.2 W @ 10/12/24/48/
110/220 VDC
: 19 W @ 24/110/220 RAC

2.68
59.5
2.34

: 19.2 W @ 48 RAC
68

47.5
1.87
47.5
1.87

Max. operating current . . : 1.9 A @ 10 VDC


23.5

23.5
0.93

0.93
: 1.61 A @ 12 VDC
: 0.80 A @ 24 VDC
38.5 36 38.5 36
1.52 1.42 1.52 1.42 : 0.40 A @ 48 VDC
: 0.17 A @ 110 VDC
: 0.09 A @ 220 VDC
DEUTSCH DT04 connector AMP JPT connector : 0.89 A @ 24 RAC
(parallel type) : 0.45 A @ 48 RAC
: 0.19 A @ 110 RAC
: 0.09 A @ 220 RAC
Coil insulance . . . . . . . . .: Class H (180°C - 356°F)
68.3
2.69

60.5
2.38

Weather protection . . . . .: IP65 - ISO4400


47.5

47.5
1.87

1.87

23.5 : IP69K - Deutsch DT


23.5

0.93
0.93

: IP65 - AMP JPT


: IP67 - Weatherpack
38.5 36 38.5 36
1.52 1.42 : IP67 - Metri-pack
1.52 1.42
Insertion . . . . . . . . . . . . : 100%

Flying leads with Flying leads with PACKARD Flying leads with PACKARD
Flying leads DEUTSCH DT04 connector WEATHER-PACK connector METRI-PACK connector
200 150 150
7.87 5.91 5.91
11.81
300
47.5
1.87

23.5
0.93

38.5 36
1.52 1.42

BQP19 type
DEUTSCH DT04 connector Features
ISO4400 connector
Nominal voltage tolerance : ±10%
Power rating . . . . . . . . . . : 15 W @ 12 VDC
: 15 W @ 24 VDC
Max. operating current . . : 1.25 A @ 12 VDC
75.2
2.96
66.5
2.62

: 0.63 A @ 24VDC
53.8
2.13
2.09
53

Coil insulance . . . . . . . . . : Class H


22.5

22.5
0.89

0.89

(180°C - 356°F)
Weather protection . . . . . : IP65 - ISO4400
55 45 55 45 : IP69K - Deutsch DT
2.17 1.77 2.17 1.77 : IP65 - AMP JPT
Insertion . . . . . . . . . . . . : 100%
AMP JPT connector
68.2
2.69

55.3
2.18

22.5
0.89

55 45
2.17 1.77

D1WWEB02E 39
SDE030-SDE060 accessories

Coils and connectors ___________________________________________________________________________________

D12C type

DEUTSCH DT04 connector


ISO4400 connector Features
Nominal voltage tolerance : ±10%
Power rating . . . . . . . . . . : 36 W @
. . . . . . . . . . . . . . . . . . .: 10.5/12/24 VDC

2.99
76
2.48

Max. operating current . . : 3.43 A @ 10.5 VDC


63

2.01

2.01
51

51
: 3 A @ 12 VDC

22.5
0.89
22.5
0.89

: 1.5 A @ 24VDC
Coil insulance . . . . . . . . . : Class H (180°C - 356°F)
50 35 50 35 Weather protection . . . . . : IP65 - ISO4400
1.97 1.38 1.97 1.38 : IP69K - Deutsch DT
: IP65 - AMP JPT
Flying leads with
Insertion . . . . . . . . . . . . : 100%
DEUTSCH DT04 connector
Flying leads
340
13.39
AMP JPT connector
12.20
310

2.68
68
2.01

2.01
51

51

22.5
22.5

0.89
0.89

50 35 50 35
1.97 1.38 1.97 1.38

D15C type

ISO4400 connector DEUTSCH DT04 connector Features


Nominal voltage tolerance : ±10%
Power rating . . . . . . . . . . : 38 W @
12/14/24/ VDC
66.5
2.62
65.5
2.58

Max. operating current . . : 3.16 A @ 12 VDC


52.5
2.07

: 2.75 A @ 14VDC
22.5

22.5
0.89

0.89

: 1.58 A @ 24VDC
Coil insulance . . . . . . . . . : Class H
54.2 Ø45 54.2 Ø45 (180°C - 356°F)
2.13 Ø1.77 2.13 Ø1.77 Weather protection . . . . . : IP65 - ISO4400
: IP69K - Deutsch DT
Flying leads : IP65 - AMP JPT
Insertion . . . . . . . . . . . . : 100%
300
11.81
AMP JPT connector
66.5
2.62
53.5
2.11

22.5

22.5
0.89

0.89

54.2 Ø45 54.2 Ø45


2.13 Ø1.77 2.13 Ø1.77

40 D1WWEB02E
accessories SDE030-SDE060
____________________________________________________________________________________________
Fixing brackets
Dimension (*) are referred to directional valve with N1 type inlet section.

SDE030 valve SDE060 valve


3.90 *
99 *

1.41
29
0.098
2.5
9
0.37
9.5

0.35
0.24
6

2.56
1.34

65
34

21.5
0.85
F
8 G
0.32 F
H

N type inlet section N1 type inlet section N2 type inlet section N6-N7 type inlet section
TYPE G H G H G H G H
mm in mm in mm in mm in mm in mm in mm in mm in
SDE030/1 143 5.63 159 6.26 166.5 6.56 182.5 7.19 191 7.52 207 8.15 183.5 7.22 199.5 7.85
SDE030/2 189 7.44 205 8.07 212.5 8.37 228.5 9.00 237 9.33 253 9.96 229.5 9.04 245.5 9.66
SDE030/3 235 9.25 251 9.88 258.5 10.18 274.5 10.81 283 11.14 299 11.77 275.5 10.85 291.5 11.48
SDE030/4 281 11.06 297 11.69 304.5 11.99 320.5 12.62 329 12.95 345 13.58 321.5 12.66 337.5 13.29
SDE030/5 327 12.87 343 13.50 350.5 13.80 366.5 14.43 375 14.76 391 15.39 367.5 14.47 383.5 15.10
SDE030/6 373 14.69 389 15.31 396.5 15.61 412.5 16.24 421 16.57 437 17.20 413.5 16.28 429.5 16.91
SDE030/7 419 16.50 435 17.13 442.5 17.42 458.5 18.05 467 18.39 483 19.02 459.5 18.09 475.5 18.72
SDE030/8 465 18.31 481 18.94 488.5 19.23 504.5 19.86 513 20.20 529 20.83 505.5 19.90 521.5 20.53
SDE030/9 511 20.12 527 20.75 534.5 21.04 550.5 21.67 559 22.01 575 22.64 551.5 21.71 567.5 22.34
SDE030/10 557 21.93 573 22.56 580.5 22.85 596.5 23.48 605 23.82 621 24.45 597.5 23.52 613.5 24.15
SDE060/1 147.5 5.81 163.5 6.44 169.5 6.67 185.5 7.30 200 7.87 216 8.50 183.5 7.22 199.5 7.85
SDE060/2 193.5 7.62 209.5 8.25 215.5 8.48 231.5 9.11 246 9.69 262 10.31 229.5 9.04 245.5 9.66
SDE060/3 239.5 9.43 255.5 10.06 261.5 10.29 277.5 10.93 292 11.50 308 12.13 275.5 10.85 291.5 11.48
SDE060/4 285.5 11.24 301.5 11.87 307.5 12.11 323.5 12.74 338 13.31 354 13.94 321.5 12.66 337.5 13.29
SDE060/5 331.5 13.05 347.5 13.68 353.5 13.92 369.5 14.55 384 15.12 400 15.75 367.5 14.47 383.5 15.10
SDE060/6 377.5 14.86 393.5 15.49 399.5 15.73 415.5 16.36 430 16.93 446 17.56 413.5 16.28 429.5 16.91
SDE060/7 423.5 16.67 442.5 17.42 445.5 17.54 461.5 18.17 476 18.74 492 19.37 459.5 18.09 475.5 18.72
SDE060/8 469.5 18.48 485.5 19.11 491.5 19.35 507.5 19.98 522 20.55 538 21.18 505.5 19.90 521.5 20.53
SDE060/9 515.5 20.30 531.5 20.93 537.5 21.16 553.5 21.79 568 22.36 584 22.99 551.5 21.71 567.5 22.34
SDE060/10 561.5 22.11 577.5 22.74 583.5 22.97 599.5 23.60 614 24.17 630 24.80 597.5 23.52 613.5 24.15

D1WWEB02E 41
SDE030-SDE060 installation and maintenance

Installation and maintenance ________________________________________________________________________

The SDE030-SDE060 valves are assembled and tested as per the technical specification of this catalogue.
Before the final installation on your equipment, follow the below re commendations:
- the valves can be assembled in any position; in order to prevent body deformation and spool sticking mount the products
on a flat surface;
- In order to prevent the possibility of water entering the spool control kit, do not use high pressure wash down directly on the
valve;
- Prior to painting, ensure plastic port plugs are tightly in place.

A3
A2 B3
A1 B2
B1

P
T

Fittings tightening torque Nm (lbft)


SDE030 SDE060
THREAD TYPE
P and T ports A and B ports P and T ports A and B ports
BSP G 3/8 G 3/8 G 1/2 G 3/8 • G 1/2*
With O-Ring seal 35 (25.8) 35 (25.8) 50 (36.9) 35 (25.8) • 50 (36.9)*
With copper washer 40 (29.5) 40 (29.5) 60 (44.3) 40 (29.5) • 60 (44.3)*
With steel and rubber washer 30 (22.1) 30 (22.1) 60 (44.3) 30 (22.1) • 60 (44.3)*
9/16-18 (SAE 6)
UN-UNF 3/4-16 (SAE 8) 9/16-18 (SAE 6) 3/4-16 (SAE 8)
3/4-16 (SAE 8)**
With O-Ring seal 35 (25.8) 30 (22.1) 35 (25.8) 30 (22.1) • 35 (25.8)**

NOTE – These torque are recommended. Assembly tightening torque depends on many factors, including lubrication, coating
and surface finish. The manufacturer shall be consulted.

Malfunction Cause Remedy


Control spool seal due to mechanical
External leakage from electric control Locate the leakage and replace the seal.
actuation.
Excessive internal leakage on A and B Increase clearance between spools and Replace the directional control valve and
ports. body due to high wear. check the oil contamination level.
Remove and clean or replace the main
Main pressure relief valve blocked open.
relief valve.
Inability to build pressure on A and B Remove and clean or replace the port
Port relief valve open.
relief valve.
Low pump pressure and flow. Check the pump and the circuit.

42 D1WWEB02E
SDE030-SDE060

D1WWEB02E 43
7th edition July 2014 WWW.WALVOIL.COM

D1WWEB02E

You might also like