a. true
b. false
c. it depends
d. always
17. The surge impedance of the underground cable is ______ than the
surge impedance of the overhead transmission line.
a. less
b. more
c. equal
d. no relation
19. Ferranti Effect states that under certain conditions the sending
end voltage is
a. less than receiving end voltage
b. greater than receiving end voltage
c. equal to receiving end voltage
d. abnormally high
20. If the receiving end voltage is assumed same as the sending end
voltage, and the impedance of the line is the resistance of the line.
What will be the maximum steady state power transmitted over the line?
a. Vr2/Z
b. Vs2
c. zero
d. very high
29. The bundle conductors are preferred for EHV transmission line
because
a. it is easy to fabricate thin conductors and combine them to make a
bundle
b. overall inductance of the line is reduced and corona loss and radio
influences are minimum
c. height of the tower is reduced and hence cheap transmission
d. fabrication of the bundle conductors is cheap
32. It is the Space between the magnetic field and electric field
a. flux
b. Power
c. Insulator
d. permittivity
33. Which of the following power system distribution gives the greater
reliability?
a. radial system of the distribution
b. ring system of the distribution
c. D.C. three wire system of the distribution
d. A.C. three phase four wire system
43. Fair weather corona loss may be computed using the empirical
formula given by Peterson. According to Peterson’s formula corona loss
is proportional to
a. f and V2
b. f2 and V
c. f and V
d. f only
46. The Self GMR considering the total effective outside radius method
is used to evaluate:
a. Inductance.
b. Capacitance
c. Inductance and Capacitance both.
d. None of these of the overhead transmission lines.
47. In EHV transmission lines, efficiency of transmission can be
increased by decreasing the corona loss. This is achieved by:
a. Increasing the distance between the line conductors.
b. Using bundled conductors.
c. Using thick conductors.
d. Using thin conductors.
51. Insulators used for transmission line at the dead-end tower are
a. suspension type
b. shackle type
c. strain type
d. pint type
52. Economic studies have shown that D.C. transmission is cheaper than
a. c transmission for lengths
a. a. below 300 km
b. beyond 600 km
c. beyond 1200 km
d. less than 100 mile
58. A conductor with 19 strands, each of same diameter and each having
an inductance of L Henries is used for a transmission line. The total
inductance of the conductor will be
a. L
b. L/361
c. 19L
d. L/19
74. If the voltage applied to the core and sheath of a cable is halved
, the reactive power generated by the cable will be
a. Halved
b. 1/4 th of the original value
c. doubled
d. The same
79. The size of conductor on modern EHV lines is obtained based on:
a. Voltage drop.
b. permeability density.
c. Corona.
d. Skin effect
85. A short length of cable between the dead end tower and the power
transformer:
a. Always reduces the steepness of the incident wave.
b. Reduces the steepness of the wave under certain conditions only.
c. It does not change the steepness.
d. Degrease the creepage distance
86. Corona loss is less when the shape of the conductor is:
a. Circular.
b. Flat.
c. Oval.
d. Independent of shape.
92. The chief advantage of using high tension alternating current for
power transmission over long distances is that.
a. Power is transmitted with a minimum of line losses.
b. Aluminum is available for that specific design
c. There will be no insulation
d. Counterpoise is no longer used
94. The most economical size of a feeder is that size for which the
annual cost of energy lost in the feeder equals the cost of interest
and depreciation on the capital cost of the conductor material.
a. Kirchoff’s Law
b. Faraday’s Law
c. Law on Economics
d. Kelvin’s Law
101. Which one of the following tests is preferred for checking the
parameters of transmission line switchgear insulation.
a. an AC high potential test
b. a DC high potential test
c. short circuit and open circuit test
d. a power factor test
111. These are some of the power plant circuit lay – out except:
a. double bus, single circuit breaker system
b. double bus, double switch system
c. double bus, double circuit breaker system
d. ring bus system