You are on page 1of 4

60Hz Air Conditioner

Product Catalogue

Note:
All the data in this catalogue maybe changed without notice for further improvement on quality and performance.
14 SEER

48K Btu/h

24/30/36K Btu/h

18K Btu/h
12K Btu/h

High Efficiency Fixed Compressor


Well known brand fixed compressor with reliable quality.

12K Unit Rotary Compressor

24~36K Unit Rotary Compressor

48K Unit Scroll Compressor

High Efficiency Motor


AC/DC motors are adopted, which is single speed. 12K-30K outdoor units adopt AC motor,
and 36K-48K outdoor units adpot DC motor.

High efficiency fan motor is from well-known brand.

R410A 14SEER SERIES Low noise and high efficiency because of high-density wire winding engineering.

Brushless with built-in sensor.

CONDENSING UNIT
Fan motor
14 SEER 14 SEER

Environment Friendly 24V Communication Connection

24V low voltage communication connection is much safer than others and it is
easier to connect to other brand indoor units.
Refrigerant R410A(HFC),low carbon footprint, no harm to Ozone.

R410A(HFC),low carbon footprint, no harm to Ozone.


Str
atos
t p her
igh e
UVL
UV light
re
phe
pos
Tro

Ozone, Protects us from UV light

R22(HCFC)is destroying Ozone


Multi protections

Sensor T3(condenser pipe temperature):When open-circuit/short-circuit, compressor, fan motor and reverse valve will be OFF.
R410A(HFC)no harm to Ozone(ODP=0) Discharge temperature protection:When discharge temp. too high, compressor will stop.
High pressure protection:When high pressure > 4.5Mpa, compressor and fan motor will stop,When high pressure<3.8Mpa, compressor
and fan will restart.
In stand-by status, the compressor will not start in low pressure protection.In 20mins, if 3 times protection occurs, it will restore after
power cut-down.

CCT Inner-grooved Tube

CCT (Continuous Cooling Transformation)inner-grooved copper tube has high thermometic conductivity. This inner-grooved fins break
the refrigerant flow boundary layer to enhance refrigerant disturbance to increase heat-exchanging efficiency. Discharge Temp. Sensor T3 Low Pressure High Pressure
Protection Protection Protection Protection
Coefficient of heat transfer W/(m²·K)

Coefficient of heat transfer W/(m²·K)

11000
6000

8000
Wide operation temperature range
5000

For Seer 14 R410A condensing unit,it has a wide operation temperature range,cooling from 64⁰F to 115⁰F,suitable for different
Refrigerant mass flow kg/(m²·s) Refrigerant mass flow kg/(m²·s)
requirements of most areas.
4000 5000
100 200 300 400 100 200 300 400

CCT Inner-grooved Tube Conventional Tube CCT Inner-grooved Tube Conventional Tube
65⁰F Cooling range 109⁰F

39⁰F Heating range 75⁰F

Concealed stop valve design 40⁰F 45⁰F 50⁰F 55⁰F 60⁰F 65⁰F 70⁰F 75⁰F 80⁰F 85⁰F 90⁰F 95⁰F 100⁰F 105⁰F 110⁰F 115⁰F 120⁰F

Compared with previous generation,the new Seer 14 condensing unit adopts completely new cabinet appearance design with high Cooling Capacity Heating Capacity Net Dimension Liquid/Gas side Max. refrigerant Max. difference
Model SEER HSPF
(Btu/h) (Btu/h) (WxHxD) (inch) (inch) pipe length(ft) in level(ft)
market recognization and stronger structure. The concealed stop valve design could protect the stop valve effectively from accidental
operation by children. COU-12CBR1-E 12000 / 14-14.5 / 33-1/3×22×13-1/10 Ф1/4/Ф1/2 82 33
COU-18CNR1-E 17500 / 14-14.5 / 36-4/5×27-3/5×15 Ф1/4/Ф1/2 82 33
COU-24CNR1-E 23500 / 14-14.5 / 40-3/5×31-9/10×17-1/2 Ф3/8/Ф5/8 82 33
COU-30CNR1-E 30000 / 14-14.5 / 40-3/5×31-9/10×17-1/2 Ф3/8/Ф3/4 82 33
COU-36CNR1-E 34000 / 14-14.5 / 40-3/5×31-9/10×17-1/2 Ф3/8/Ф3/4 82 33
COU-48CNR1-E 46000 / 14-14.5 / 43-1/3×34-1/4×20-4/5 Ф3/8/Ф3/4 98 49
Concealed stop valve design
COU-12HBR1-E 12000 11109 14 8.2 33-1/3×22×13-1/10 Ф1/4/Ф1/2 82 82
COU-18HBR1-E 17000 17500 14 8.2 36-4/5×27-3/5×15 Ф1/4/Ф1/2 82 82
COU-24HBR1-E 23000 21200 14 8.2 40-3/5×31-9/10×17-1/2 Ф3/8/Ф5/8 82 82
COU-30HBR1-E 28600 27000 14 8.2 40-3/5×31-9/10×17-1/2 Ф3/8/Ф3/4 82 82
COU-36HBR1-E 33000 33000 14 8.2 40-3/5×31-9/10×17-1/2 Ф3/8/Ф3/4 82 82
Previous generation New generation COU-48HBR1-E 47000 48000 14 8.2 43-1/3×34-1/4×20-4/5 Ф3/8/Ф3/4 98 98

Note: The above data may be changed without notice for future improvement on quality and performance.
ECO Side Discharge

5 Ton

Performance Features

24V Communication Protocol. Low Noise


24V communication protocol is much safer than others and compatible with any Quiet 54-58dB(a) operation.
third-party air handler and thermostat Including NEST®. it is easier to connect to
other brand indoor units.

whisper mosquito rainfall conversation shower blow dryer


dB(A)
30 40 50 60 70 80

High Efficiency Motor


Famous brand fan motor of high-density wire winding engineering and built-in
sensor,reliable,high efficiency and low noise.

third-party third-party
air handler thermostat

CCT Inner-grooved Tube


CCT inner-grooved copper tube has high thermometic conductivity. it breaks the
refrigerant flow boundary layer to increase heat-exchanging efficiency.
High efficiency fan motor

Coefficient of heat transfer W/(m²·K)

Coefficient of heat transfer W/(m²·K)


11000
6000

5000 8000
Low noise and high efficiency

Refrigerant mass flow kg/(m²·s) Refrigerant mass flow kg/(m²·s)

Built-in sensor
4000 5000
100 200 300 400 100 200 300 400

Fan motor
CCT Inner-grooved Tube Conventional Tube CCT Inner-grooved Tube Conventional Tube

Specification
Outdoor Model COU-60CNR1-050 COU-60CXR1-050
Capacity Btu/h 60000 60000
Power V/N/Hz 208~230/1/60 208~230/3/60
Compressor LG COPELAND
Type SCROLL SCROLL
ODU

R410A ECO SERIES


Total Piping Length m 20 20
Piping Lift m 10 10
Pipe Connection Size-Liquid mm 9.52 9.52
Pipe Connection Size-Suction mm 19.05 19.05

SIDE DISCHARGE ODU


Dimension(WXHXD) mm 964X402X1445 964X402X1445
Airflow CFM 2400 2400