You are on page 1of 2

Three Phase Hybrid Inverter Technical Data

Model
SUN-6K
-SG01HP3-EU
SUN-8K
-SG01HP3-EU
SUN-10K
-SG01HP3-EU
SUN-12K
-SG01HP3-EU
SUN-15K
-SG01HP3-EU

SUN- 6 / 8 / 10 / 12 / 15 K-SG01HP3-EU Battery Input Data


Battery Type Lead-acid or Li-lon
Battery Voltage Range (V) 96~600
Max. Charging Current (A) 37
Max. Discharging Current (A) 37
Number of battery input 1
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 7800 10400 13000 15600 19500
Max. DC Input Voltage (V) 1000
Start-up Voltage (V) 160
MPPT Range (V) 200-850
Full Load DC Voltage Range (V) 300-850
Rated DC Input Voltage (V) 150
PV Input Current (A) 26+26
Max. PV ISC (A) 40+40
Number of MPPT / Strings per MPPT 2/2+1
AC Output Data
Rated AC Output and UPS Power (W) 6000 8000 10000 12000 15000
Max. AC Output Power (W) 6600 8800 11000 13200 16500
AC Output Rated Current (A) 9.1 12.1 15.2 18.2 22.7
Max. AC Current (A) 13.6 18.2 22.7 27.3 34.1
Max. Continuous AC Passthrough (A) 50
Peak Power (off grid) 2 time of rated power, 10 S
Generator input/Smart load
/AC couple current (A) 9.1 / *180 / 9.1 12.1 / *180 / 12.1 15.2 / *180 / 15.2 18.2 / *180 / 18.2 22.7 / *180 / 22.7
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type Three Phase
DC injection current (mA) <0.5%1n
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency 99.90%
Protection
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Integrated Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge protection
Output Over Voltage Protection DC Type II/AC Type III
Certifications and Standards
100% unbalanced output, each phase; Max.

Alarm
AC Normal
DC

CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98,
15:34:40
05/28/2019

0 12.00 15
0 -3.00
KW
15

output up to 50% rated power Grid Regulation


VDE 0126-1-1, RD 1699, C10-11
KW ON

25%

0 3.00 15
KW

0 -6.00 15
KW

Up

Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2


Esc
Enter

DC couple and AC couple to retrofit existing


General Data
Down

DC AC Normal Alarm

solar system
Operating Temperature Range (℃) -45~60℃, >45℃ derating
Cooling Smart cooling
Max. 16pcs parallel for on-grid and off-grid
 operation; Support multiple batteries parallel Noise (dB) <45 dB
Communication with BMS RS485; CAN
Weight (kg) 26
 Max. charging/discharging current of 37A Size (mm) 396W×580H×230D
Protection Degree IP65
Installation Style Wall-mounted
High voltage battery, higher efficiency
Warranty 5 years

 6 time periods for battery charging/discharging

Support storing energy from diesel generator


53 54
www.deyeinverter.com www.deyeinverter.com
Three Phase Hybrid Inverter Technical Data
Model
SUN-20K
-SG01HP3-EU
SUN-25K
-SG01HP3-EU
SUN-30K
-SG01HP3-EU
SUN-40K
-SG01HP3-EU
SUN-50K
-SG01HP3-EU

SUN- 20 / 25 / 30 / 40 / 50 K-SG01HP3-EU Battery Input Data


Battery Type Lead-acid or Li-lon
Battery Voltage Range (V) 200~700
Max. Charging Current (A) 37 37+37
Max. Discharging Current (A) 37 37+37
Number of battery input 1 2
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 26000 32500 39000 52000 65000
Max. DC Input Voltage (V) 1000
Start-up Voltage (V) 160
MPPT Range (V) 200-850
Min. DC Input Voltage (V) 150
Full Load DC Voltage Range (V) 360-850 365-850 435-850 450-850 450-850
Rated DC Input Voltage (V) 500 625 500 500 625
PV Input Current (A) 36+36 36+36+36 36+36+36+36
Max. PV ISC (A) 55+55 55+55+55 55+55+55+55
Number of MPPT / Strings per MPPT 2/2+2 3/2+2+2 4/2+2+2+2
AC Output Data
Rated AC Output and UPS Power (W) 20000 25000 30000 40000 50000
Max. AC Output Power (W) 22000 27500 33000 44000 55000
AC Output Rated Current (A) 30.3 38 45.6 60.8 75.8
Max. AC Current (A) 45.5 56.8 68.2 90.9 113.6
Max. Continuous AC Passthrough (A) 100
Peak Power (off grid) 2 time of rated power, 10 S
Generator input/Smart load
/AC couple current (A) 30.3 / *180 / 30.3 38 / *180 / 38 45.6 / *180 / 45.6 60.8 / *180 / 60.8 75.8 / *180 / 75.8
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type Three Phase
DC injection current (mA) <0.5%1n
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency 99.90%
Protection
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,
Integrated Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,
Output Shorted Protection, Surge protection
Output Over Voltage Protection DC Type II/AC Type III
100% unbalanced output, each phase; Max.
 output up to 50% rated power
Certifications and Standards
Grid Regulation CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98,
VDE 0126-1-1, RD 1699, C10-11
05/28/2019 15:34:40

DC couple and AC couple to retrofit existing


Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
0 -3.00 50
0 12.00 50 KW
KW
ON

25%
DC AC Normal Alarm

solar system
0 3.00 50
0 -6.00
KW
50 KW

General Data
Operating Temperature Range (℃) -45~60℃, >45℃ derating
Max. 16pcs parallel for on-grid and off-grid
 operation; Support multiple batteries parallel Cooling Smart cooling
Noise (dB) <45 dB
Communication with BMS RS485; CAN
 Max. charging/discharging current of 74A Weight (kg) 60
Size (mm) 560.5W×837H×319D
Protection Degree IP65
High voltage battery, higher efficiency
Installation Style Wall-mounted
Warranty 5 years

 6 time periods for battery charging/discharging

Support storing energy from diesel generator


55 56
www.deyeinverter.com www.deyeinverter.com

You might also like