12 11 10 9 8 7 6 5 4 3 2 1
0 EPCC05-MDR-421-STR-DWG-000-0072-04 PLAN AND DETAILS
REV. DWG NO STRIPPER AND STABILIZATION AREA MISCELLANEOUS SUPPORTS TITLE

100 360 165 196 165 196


100 360 MS-4216-1036
(TOS) (TOS) MS-4216-1033
(TOS) ISMC150 ISMC150 ISMC150
8 THK STIFF PLT 8 THK STIFF PLT (TOS) ISMC150
(N/S & F/S) (N/S & F/S) MS-4216-1035
MS-4216-1018 UC152X152X30 UC152X152X30
8 THK STIFF PLT

Revision 0-IFC TYP 6


H UC203X203X46 ISMC150 (N/S) H
6 6 (3 SIDES) TYP
6 6 6
3 SIDES (TYP) 6 MS-4216-1034 ISMC150 (TOS)
W W 6 UC152X152X30
(TOS) 6

Date: 24-JULY-2023
6
E- 2943.400 BP- 3 (3 SIDES) TYP
6
N- 1551.585
435 8 THK STIFF PLT
(N/S) 450 8 THK STIFF PLT
(N/S)
SECTION D - D
E- 2943.670
SECTION A - A SECTION B - B SECTION C - C
(BACK OF CHANNEL)
V N- 1543.925 NOTES
720 100
MS-4216-1021 (TOS)
U ISMC150 400 700 100 420 1. ALL DIMENSIONS ARE IN MILLIMETERS. ALL COORDINATES & ELEVATIONS ARE
BP - 1A 720 100 (TOS) UC152X152X30 (TOS) IN METER UNLESS NOTED OTHERWISE.
(TOS) 8 THK STIFF PLT 2. ALL ELEVATIONS ARE WITH REFERENCE TO HIGHEST POINT OF PAVING (HPP)
E- 2941.965 UC152X152X30 (N/S & F/S)
G (BACK OF CHANNEL) EL 99.600 CORRESPONDS TO REDUCED LEVEL (RL) 42.900. G
8 THK STIFF PLT 8 THK STIFF PLT
BP - 1A 8 THK STIFF PLT UC152X152X30 3. FOR GENERAL NOTES AND STEEL STRUCTURAL STANDARD DRAWINGS REFER
N- 1543.875 (N/S & F/S)

MS-4216-1026
(N/S & F/S) 6 (N/S & F/S) EPCC05-MDR-421-STR-DWG-000-0016-01 THRU 0016-18

UC152X152X30
E- 2946.710 UC152X152X30
MS-4216-1020 N- 1543.045 MS-4216-1031 6
4. ALL STRUCTURAL STEEL ROLLED SECTION & FLAT SHALL CONFORM TO IS 2062,
ISMC150
UC152X152X30
MS-4216-1032 6 (E250 GRADE -BR/BO) & IS 800 & IS 808 U.N.O. & PLATES BE CONFORM TO E250BR
6
V MS-4216-1037
MS-4216-1030
UC152X152X30 AS PER IS 2062. BESIDES, UNIVERSAL SECTIONS MANUFACTURED BY M/
U UC152X152X30
UC152X152X30 STEEL OR EQUIVALENT CAN ALSO BE USED CONFORM TO IS 12778.
5. ALL CONNECTIONS ARE WELDED CONNECTIONS UNO.
T T 6. ALL STRUCTURAL CONNECTION BOLTS & NUTS SHALL CONFORM TO BE HIGH
STRENGTH BOLTS (CLASS 8.8) CONFIRMING TO IS 3757, IS 4000 & IS 6649.
BP - 1
7. WHERE REQUIREMENT IN DETAIL ENGINEERING ARE IN CONTRADICTION TO
SECTION F - F REQUIREMENT IN STANDARD DRAWINGS THE DETAIL DRAWING SHALL GOVERN
SECTION G - G 8. READ THIS DRAWING IN CONJUNCTION WITH DRAWING NO
SECTION E - E SECTION H - H EPCC05-MDR-421-STR-DWG-000-0072-02, 03 & 05.
9. BASE PLATE BP-1, BP-1A & BP-2 SHALL BE WELDED TO EMBEDDED PLATES AT
SITE WITH 8MM FILLET WELD ALL AROUND.
MS-4216-1038 100 300
F UC152X152X30 100 420 200 500 100 300 F
UC152X152X30 (TOS) UC152X152X30 UC152X152X30
R E- 2946.350 (TOS) UC152X152X30 (TOS) (TOS)
BP - 1A N- 1541.150 8 THK STIFF PLT
Q MS-4216-1023 (N/S & F/S) 8 THK STIFF PLT 8 THK STIFF PLT 8 THK STIFF PLT
ISMC150 (N/S & F/S) (N/S & F/S) (N/S & F/S)
E- 2941.965 6

MS-4216-1118
(BACK OF S S

UC152X152X30
E- 2943.645 6 6

MS-4216-1024
6

MS-4216-1027

MS-4216-1025
UC152X152X30
UC152X152X30

UC152X152X30
CHANNEL) (BACK OF
BP - 1A BP - 1
N- 1540.875 CHANNEL)
N- 1540.985
MS-4216-1022 R
ISMC150 Q

SECTION J - J SECTION K - K
SECTION L - L SECTION M - M
REFERENCE
E 100 200 E
200 225 Doc. No. Title
(TOS) ISMC150 EPCC05-MDR-421-PIP-PLT PLOT PLAN
(TOS) 100 350 -000-0001-01 PLAN & SECTIONS UNIT (421) 120M X 85M
M ISMC150
100
L MS-4216-1024 MS-4216-1025 ISMC150 (TOS)
350
(TOS) STANDARD DRAWING FOR STEEL STRUCTURE
8 THK STIFF PLT ISMC150 EPCC05-MDR-421-STR-DWG
UC152X152X30 UC152X152X30 6 8 THK STIFF PLT
BP - 1 (N/S) -000-0016-01 THRU 18
BP - 1 350 6

MS-4216-1029

MS-4216-1028
(N/S)

MS-4216-1022
495 6 325 8 THK STIFF PLT

MS-4216-1023
CWP 4216
E- 2941.435 P (TOS) (TOS) ISMC150
(N/S) 6
8 THK STIFF PLT
(N/S)
(TOS)

ISMC150

ISMC150
E- 2939.355 N- 1538.500 MS-4216-1029 ISMC150 545

ISMC150
MS-4216-1028

ISMC150
N- 1538.500 (TOS)
M N ISMC150
ISMC150 ISMC150 ISMC150
L BP - 1A E- 2943.675
BP - 1A
KEY PLAN
(BACK OF 8 THK STIFF PLT
E- 2941.965
CHANNEL) 8 THK STIFF PLT (N/S) 8 THK STIFF PLT
(BACK OF 8 THK STIFF PLT C OF NEW ROAD WIDTH 7.5M

N- 1537.885 (N/S) (N/S) N 1654.250 L

CHANNEL) (N/S)
N- 1537.825
N P SECTION N - N SECTION P - P

E = 2894.600
D SECTION Q - Q SECTION R - R N = 1632.750 BATTERY LIMIT
421-M-004 421-M-005 421-M-006
D

MS-4216-1118 400 240


BP - 1 UC152X152X30 100 600

C OF NEW ROAD WIDTH 6M


(TOS) MS-4216-1037 100 100 285
J UC152X152X30 (TOS) 350

421-DH-002
E- 2943.520 UC152X152X30

C OF NEW ROAD WIDTH 6M


N- 1536.575 8 THK STIFF PLT ISMC150 (TOS)
H

PR-1

SHED FOR LUBE

DRUM STORAGE
(HOLD-14)
OIL/CHEMICAL
(TOS)

L
8 THK STIFF PLT ISMC150
(N/S & F/S) 8 THK STIFF PLT
N 1579.750

MS-4216-1026 MS-4216-1027

L
(N/S & F/S) 8 THK STIFF PLT

BATTERY LIMIT
MS-4216-1037

E 2997.600
UC152X152X30 6 (N/S)

(HOLD-10)
UC152X152X30 MS-4216-1038
K K
N 1566.250

(N/S)
UC152X152X30
6

E 2876.600
BP - 1

UC152X152X30
BP - 1

MS-4216-1021
421-K-01
421-KT-01

325 400 6

MS-4216-1020
6
(TOS) (TOS)
N 1547.250

E- 2939.490 E- 2941.435 ISMC150 ISMC150

ISMC150
N- 1536.070 N- 1536.070

ISMC150
N 1531.750

H J

421-DH-001
BATTERY LIMIT

8 THK STIFF PLT N 1502.850 MAINTENANCE ACCESS WAY

MS-4216-1032 8 THK STIFF PLT


(N/S)
C UC152X152X30 (N/S) C

E- 2943.510
SECTION S - S SECTION T - T SECTION U - U SECTION V - V
N- 1534.675 E- 2958.315
MS-4216-1031 550 520
"Code D" endorsed on contractor's drawings / documents by
E MS-4216-1030 F UC152X152X30 (BACK OF PMC / Client shall not relieve the contractor from full
responsibility
BP - 1 CHANNEL) MS-4216-1018
UC152X152X30
BP - 1
G BP - 4 G N- 1544.245 MS-4216-1115 (TOS) UC203X203X46 190 190 for any errors or omissions therein or limit the contractor's
ISMC150 obligations for conformance to codes, ITB specifications,
(TOS)
safety etc.
E- 2941.435
E- 2939.307
N- 1534.270
N- 1534.270 10 10 ISMC150
“ This is information category document. Document retained 0 14.06.2023 ISSUED FOR INFORMATION RV RTI PAB
MS-4216-1115 for information.
MS-4216-1018

PERP REVW APPD


UC203X203X46

It is Contractors responsibility to ensure that all ITB/ Codal REV. DATE PURPOSE BY
BP - 1A ISMC150 BY BY
F C D MS-4216-1033 requirements are complied and loads applied in design are in
PROJECT
E BP - 1A BP - 1A ISMC150 line with vendor GA / MDS./CIVIL INFO. Any discrepancies
found at later stage shall be rectified by contractor without any
BR-9 EXPANSION PROJECT
MS-4216-1036 E- 2943.670
cost and schedule impact.” NEW DIESEL HYDROTREATING UNIT
ISMC150 (BACK OF Contractor to Update all PMC comments given on similar type CLIENT
B
E- 2941.956
CHANNEL) SECTION 10 - 10 of facility of Approval category drawings / documents in
INDIAN OIL CORPORATION LIMITED
B
N- 1533.335 Information Category documents.
(BACK OF D SECTION W - W
CHANNEL)
C LOCATION: BARAUNI, BIHAR, INDIA
N- 1533.335
PMC
400 FOR TOYO ENGINEERING INDIA PVT. LTD. (PMC) USE ONLY TOYO E NGINEERING I NDIA PVT. LTD.
350 MUMBAI-INDIA
B
250
250
150 150
4 - 24 Ø HOLES FOR
125 125 4 - 24 Ø HOLES FOR
TOYO ENGINEERING INDIA PVT. LTD. TEIPL JOB NO. 6373
MS-4216-1035 ANCHOR BOLTS
A MS-4216-1034 UC152X152X30
88 162 125 125 ANCHOR BOLTS MUMBAI - 400 078
UC152X152X30 8 TYP CONTRACTOR CONSORTIUM OF CBI CONSTRUCTORS PTY LTD
8 6 TYP A Approved/ Reviewed No Comments
50

BP- 1 6 6 AUSTRALIA AND CB&I INDIA PRIVATE LIMITED


150

E- 2941.435 TYP
125

E- 2939.355 6
125

N- 1531.550 TYP 6 B Reviewed with comment Document needs to be resubmitted


N- 1531.550 6
250

150

400

10 This Document or drawing is sole property and copyright of McDermott. It contains confidential
250

TYP
350
Engineering Contractor and propriety information. This document or drawings can not be reproduced, copied, retained
20 THK. 10 C Not Approved Document needs to be resubmitted CB&I s.r.o or used, in whole or in part without written consent of McDermott.
150

BP - 1
125

125

BASE PLATE TYP 10


D Not for Approval Retained for Information/ Records
50

TITLE
A B 20 THK. 10 20 THK.
A BASE PLATE BASE PLATE
DATE 22-June-2023 TOYO JOB NO. STRIPPER AND STABILIZATION AREA A
BP - 1A BP - 1 MISCELLANEOUS PIPE SUPPORTS
PLAN AT EL+99.750 (SEE NOTE 9) (SEE NOTE 9)
BP - 3 BP - 4 VA VA Rajesh Gaikwad
-
SIGN PLAN AND DETAILS -
AE LAE TM/DH DWG. NO. REV.
SCALE : NTS
NOTE: Review by PMC/TOYO whether or not resulting in comments shall not relieve Contractor of any obligations or requirements under the
contract and it shall not be construed as an authorization of or consent to any deviation from contract.
EPCC05-MDR-421-STR-DWG-000-0072-04 0

12 11 10 9 8 7 6 5 4 3 2 1