LIFE SAVING EQUIPMENT FIRE FIGHTING EQUIPMENT

SYMBOL DESCRIPTION QTY. SYMBOL DESCRIPTION LOCATION QTY. TOTAL


LIFEBUOY FITTED WITH 30m LIFELINE 4 CO2
WHEELHOUSE (2.3Kg)
PAINT STORE OUTSIDE (6.8Kg)
2
1
CO2 5
5 FIRE EXTINGUISHER STEERING GEAR COMP (6.8Kg) 1
LIFEBUOY FITTED WITH ELECTRIC B/T COMPARTMENT (6.8Kg)
BATTERY SELF-IGNITING LIGHT 2 1

10 lbs DRY CHEMICAL GALLEY 1


LIFEBUOY FITTED WITH SMOKE SIGNAL
COMPLEMENT - 32 MAN
P 3
2 FIRE EXTINGUISHER ENGINE RM. 2
& SELF-IGNITING LIGHT 10

FORECASTLE ACCOMMODATION 2
25 MEN INFLATABLE LIFERAFT 4 9 LITRES WATER
FLAG: BAHRAIN
LW MAIN DECK ACCOMMODATION 3
7
9 FIRE EXTINGUISHER PROV. STORE 1
FWD. STORE 1
6 MENRESCUE/WORK BOAT (TO SOLAS) 1
F ENGINE RM. 3
9
9 LITRES FOAM FIRE EXTINGUISHER 4
ENGINE RM. ENTRANCE 1
HADI 9 FIRST AID KIT (25 MEN) 3
45 LITRES FOAM-MECHANICAL ENGINE RM. 1 1
LINE THROWING APPARATUS 1

WHEELHOUSE DECK 2
PARACHUTE DISTRESS ROCKET 12 50mm Ø FIRE HYDRANT FORECASTLE DECK 2
11

MAIN DECK 4
RADAR TRANSPONDER 2 FIRE HOSE BOX CONTAINING 50mm x 15m.
HADI 9 LENGTH HOSE OF DUAL PURPOSE TYPE ENGINE ROOM. 2
INCORPORATING A SHUT-OFF. 11
B/T COMPARTMENT 1
TWO WAY VHF RADIO 3 (SPRAY & JET NOZZLE)
EBI
20 TON

RESCUE ZONE
5000
TOOL BOX
1800

C.L. E.P.I.R.B. 1 GALVD. STEEL BUCKET


MAIN DECK 2
3
RESCUE ZONE (P&S) FORECASTLE DECK 1

L
24V DC EMERGENCY LIGHT (NEAR 2
W.B. F.O. LIFERAFT EMBARKATION AREA) FIREMAN'S AXE
FORECASTLE DECK 1 3
(P&S) DAY TK. HYD. OIL MAIN DECK 2
W.B.
(P&S)
TK (S) L.O. STORAGE
F.O. F.W. BOW THRUSTER COMPT. EMBARKATION ROPE LADDER 2 WHEELHOUSE 1
TANK (P) FORE PEAK
(P&S) (P&S) & FWD MACHINERY ROOM W.B FORECASTLE ACCOMMODATION 1
S.C. MAIN DECK ACCOMMODATION 4
(P&S) EMBARKATION STATION 2 GALLEY
SEWAGE 1
TANK STEERING GEAR COMP. 1 12
GENERAL/FIRE ALARM BELL 1
ENGINE CONTROL RM.
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 LIFE JACKET 40 ENGINE ROOM 2
OUTBOARD PROFILE B/T COMPARTMENT 1

F IMMERSION SUIT 3
WHEELHOUSE 2
1
FORECASTLE ACCOMMODATION
MAIN DECK ACCOMMODATION 4
GALLEY 1 13
MANUAL OPERATED CALL POINT
DN EMERGENCY ESCAPE BREATHING DEVICE 6 STEERING GEAR COMP. 1
1
ENGINE CONTROL ROOM
ENGINE ROOM 2
B/T COMPARTMENT 1
ML MUSTER LIST AND TRAINING MANUAL 1
EXH. BATT. FIRE ALARM PANEL WHEELHOUSE 1 1
LIFERAFT
ROOM 1
DN
FE A-60 CLASS BULKHEAD CO2 ENGINE ROOM 2
1 SIREN/FLASHING LIGHT FOR CO
2 ALARM 1
3
OFFICE ENGINE CONTROL ROOM
1 WHEELHOUSE 1
A-0 CLASS BULKHEAD
H
CO2 FE FIREMAN OUTFIT (SEE NOTE) 2
COMPUTER TABLE

UP A.H.U.
5 OFFICE 1
FE ROOM
3
F 3
FIRE LW
B-0 CLASS BULKHEAD WHEELHOUSE 1
PUSH BUTTON FOR GENERAL ALARM 2
STOP

LW
2

STOP
2
SCROLL

DIMMER

STOP

WTD
9
PLAN ENGINE CONTROL ROOM 1
25
20

100
X
15
10

60 65 70 75 45 50 55 60 65 75 80 85
STAIRWAY
W/C
12
DN UP A-60 CLASS SELF-CLOSING DOOR
FLASHING LIGHT & SIREN FOR FIRE ALARM ENGINE ROOM
2
STOP

STOP
2
SCROLL

2 2
DIMMER

STOP

FIRE 6
25
20

100
X
15
10

PLAN 2 A- 0 CLASS SELF-CLOSING DOOR


CO2
ML CAPTAIN
5 BILGE/BALLAST/FIRE PUMP ENGINE ROOM 1 1
1
2 A-60 CLASS FIRE PROOF DOOR (40m3 /HR @ 45m HD)
GPS NAVTEX

BILGE / G.S/FIRE PUMP


ENGINE ROOM 1 1
(40m 3 /HR @ 45m HD)
A- 0 CLASS FIRE PROOF DOOR
LIFERAFT
EXH.
EMERGENCY FIRE PUMP
B/T COMPARTMENT 1 1
(25m 3 /HR @ 45m HD)
B- 0 CLASS FIRE PROOF DOOR
WHEELHOUSE DECK
INTERNATIONAL SHORE CONNECTION MAIN DECK 1 1

FORECASTLE DECK PRIMARY MEANS OF ESCAPE 2


WHEELHOUSE
FORECASTLE ACCOMMODATION 3
FIRE MAIN DECK ACCOMMODATION 6
FIRE CONTROL PLAN CORF. ROOM 1
PLAN SMOKE DETECTORS A/C MACHY. RM. 1 19
STEERING GEAR COMP. 1
ENGINE CONTROL ROOM 1
FIRE PAINT ENGINE ROOM 2
UP
STORE 2 B/T COMPARTMENT 1
PLAN
L CO2
CASING
2 MEN 2
NOTES FOR FIRE FIGHTING: GALLEY 1
5 CO2 ENGINE ROOM
HEAT DETECTOR 3 5
CO2

RM EXH.
1. A SPARE CHARGE SHALL BE PROVIDED FOR EACH PORTABLE
CO2

B/T COMPARTMENT
CO2
1
4
LW
EXTINGUISHER.
9 2 SPACE PROTECTED BY CO
2 ENGINE ROOM
2. TO BE ABS APPROVED THREE (3) SETS OF FIREMAN'S OUTFIT TO BE PROVIDED:
V.L. CO2
4 MEN
1 MAN/
2 SICK 1 W/P
a) ONE ALUMINIUM PROTECTIVE CLOTHING. FUEL SUPPLY VALVE / VENT (ER)
4
BAY
ESCAPE 4 MEN GROUP UP WITH F.O. L.O. H.O. ETC MAIN DECK 1
TRUNK
b) ONE (1) COMPLETE SET BREATHING APPARATUS PUMPS EMERG. STOP BUTTON
2 c) ONE FIREMAN'S AXE. REMOTE SHUT-OFF
FIRE
LW
WINCH

F LW LW C.L. 9
ONLY

9 9
PLAN 9 2B d) ONE SAFETY LAMP OF PORTABLE BATTERY TYPE. FIRE FLAP FUNNEL 2 2
0 5 10 15 20 25 30 35 40 45 50 55 60 65 UP 70 75 80 85 e) ONE SET OF GLOVES & BOOTS.
DN C.L.
CHILLER FREEZER
CREW f) A RIGID HELMET. FIRE DAMPER IN VENT DUCT GALLEY 1 1
PANTRY MESS
LAUNDRY
VENT FANS FOR E/R, PURIFIER RM
REMOTE SHUT-OFF E/R VENT 1 1
SHELTERED PROV. P
V.L.
WELDING AREA LW
STORE
FB 10
PORTABLE FOAM APPLICATOR ENGINE ROOM
9
1 1
EMERGENCY EXH.
OFF. NOTES FOR LIFE SAVING: F

GALLEY MESS
GENSET ROOM CASING
1. EACH MAN ON BOARD SHALL BE PROVIDED WITH A LIFE JACKET CO2 ROOM 1
CO2 RELEASE STATION
CO2
FIRE 2
L
OUT OF CO2 ROOM 1
H PLAN LIFE JACKETS ARE TO BE SOLAS APPROVED TYPE C/W LIGHT
AND WHISTLE AND RADAR REFLECTIVE STRIP AND STOWED IN CO2 BOTTLES CO2 ROOM 13
MAIN DECK
CO2

TOOL BOX WARDROBE. (NO. OF LIFE JACKETS -40 NOS.OFF)


2. ONE (1) LINE THROWING APPARATUS CONSISTING OF FOUR (4) FIRE MAIN ISOLATING VALVE MAIN DECK 1 1
PROJECTILES AND FOUR (4) LIFELINES OF NOT LESS THAN 230m
SHALL BE PROVIDED. ENGINE ROOM 1
FB FIRE BLANKET
1
2
GALLEY
L.O. STORAGE 3. TWELVE (12) PARACHUTE DISTRESS ROCKETS SHALL BE PROVIDED
DAY TANK OVER (P&S)
TANK (P)
AND STOWED IN W/H.
F.O. TK (P) F.O. TK (P) C/D
4. TWO ORANGE SMOKE SIGNALS EACH TO HAVE 120 SECONDS
DISCHARGE TIME AND BE WATERPROOF
W.B. (P) W.B. (P)
W.B. (P) 5. MUSTER LIST AND EMERGENCY INSTRUCTUON AND OPERATING
F.O. TK (P) F.O. TK (P) DATE MODIFICATION REV BY
2

INSTRUCTION AND TRANING MANNALS SHELL BE PROVIDED


CO2
CO2

F.W. TK (P) B.W. S/C


6. SIX (6) DRICLAD TYPE 1 OR EQUAL WORK VESTS OF SELF SHIP:

54m WORK/MAINTENANCE VESSEL


F CO2 CO2 F
P
10
9 UPRIGHTING TYPE.
FIRE UP B.T.COMPT. 7. TWO DUPLICATE SET OF FIRE CONTROL PLANS BEING PERMANTELY
CO2 W.B. (U)
CO2 PLAN CO2 & FWD STORED IN A PROMINENTLY MARKED WEATHERTIGHT ENCLOSURE
5
MACHINERY RM. TITLE:
ECR OUTSIDE OF THE DECK HOUSE.
CO2
S.G COMPT. F.W. DIRTY OIL
F.O. TK (U)
W.B. (C) (C) TK (U)
Life Saving & fire Fighting Equipment Arragement
F FORE PEAK
V.T.

0 5 10 15 20 25 30 35 40 9 45 50 55CO2 60 65 70 75
75
80
80
W.B
FB
V.T.

SEWAGE
TANK
W.B. (U) OWNER HADI H AL-HAMMAM EST.
BUILDER CHEOY LEE SHIPYARDS LTD YARD NO. 4819
UP
CO2
F MACHINE TOOL P CLASS ABS
5 9 10 F.W. TK (S)

CONAN WU & ASSOCIATES


CO2 CO2
B.W.

CO2

F.O. TK (S) F.O. TK (S) CO2 W.B. (S)


W.B. (S) W.B. (S) NAVAL ARCHITECTS
UP
F.O. TK (S) F.O. TK (S)
INFORMATICS BLDG., 5 INTERNATIONAL BUSINESS PARK, JURONG EAST, SINGAPORE 609914
C/D
TEL. : (65) 562-1138 FAX : (65) 562-1238, (65) 562-0123 E-MAIL : cwaship@singnet.com.sg
BELOW MAIN DECK
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE SUPPLIED DRAWN CHECKED APPROVED SCALE DRAWING NO. REV

As
HYD. OIL
ON THE UNDERSTANDING THAT THEY ARE THE EXCLUSIVE PROPERTY OF
C3603/S-3
TK OVER (S) Nong
CONAN WU & ASSOCIATES. THEY MUST NOT BE USED OR REPRODUCED 1:150
IN WHOLE OR IN PART WITHOUT PERMISSION IN WRITING. 26-02-03 Fitted

You might also like