Timed Dose / Demand Dose Dual Pump Control Panel


NOTE: This item is not a duplex alternating, timed dosing panel. Specific to gravel filters, one pump will be time dosing and the
other will be demand dosing.

Motor Contactor Control Programmable Timed Dose Tested to UL Standard UL 508


& Certified to CSA Standard
Zoeller Pump Company control panels provide residential and C22.2 No. 205

commercial customers with a reliable means of controlling both


dose chamber and media filter pumps in septic installations.

Dose Chamber
A programmable timer activates a magnetic motor contactor to
turn the dose chamber pump on and off. A low or high water
condition overrides the timer to prevent the pump from running
dry, or turns on the pump via the timer override float. A high water
condition in the pump chamber activates the alarm.

Media Filter
A float in the media filter tank activates a magnetic contactor to
turn the media filter pump on and off. A high water condition in
the media filter basin activates the alarm and turns off the pump
in the dose chamber.
Common applications include media filter systems, pressure
Model 10-0699
distribution systems, mound systems, or any application requiring
Product may not be exactly as pictured.
a timed dose.

1. Programmable Timer - features variable control to allow 16. Ground Lug


for dose chamber on/off time settings from 0.5 seconds to 17. Float Switch Terminal Block
30 hours.
18. Dose Chamber Magnetic Motor Contactor - controls the pump by
2. Ratings Label switching both electrical lines.
3. Red Alarm Beacon - provides 360° visual 19. Backplate Hookup Diagram Label
check of alarm condition
20. Media Filter HOA Switches - provides manual control of the
4. Schematic diagram (loose in enclosure) pumps
5. Dose Chamber Circuit Breaker - provides dose chamber 21. Control Fuse
pump disconnect
22. Dose Chamber HOA Switch - provides manual pump control.
6. Media Filter Circuit Breaker - provides media filter pump
23. Alarm Fuse
disconnect 3
7. Elapsed Time Meter - for Media Filter pump monitoring 13 2 12 14 15 5 6 8 7 1

8. Power and Media Filter Pump Terminal Block - 20


includes terminals for separate pump and control power
21
9. Spare Fuse
22
10. Exterior Horn Silence/Test Switch - allows alarm horn to be
silenced; and allows alarm to be tested
9
11. Alarm Horn - provides audio warning of alarm
condition 10

12. Pump Specifications Label


13. Tested Stamp 11

14. Timer Instruction Label


15. UL Label
Note: All variable level float switches in this section are
16 18 19 4 17 23
mechanically activated and do not contain mercury.
SK2068

© Copyright 2021 Zoeller Pump Company All rights reserved.


Dose Chamber Media Filter
Part Number Voltage/Phase
FLA FLA
DISCHARGE

10-0699 120V/1 Ph 0-20 Amps 0 - 13 Amps


10-0701 230V/1 Ph 0-20 Amps 0 - 20 Amps
MEDIA FILTER

SPECIFICATIONS
Enclosure: NEMA 4X, ultraviolet stabilized, noncorrosive engineered
thermoplastic for indoor and outdoor use with removable mounting
flanges. 10”x 8”x 4” (120V); 12” x 10” x 6” (230V) INLET PIPE

Alarm/Control Section Voltage: 120 VAC, 60 Hz, single phase, 40 watt EFFLUENT FROM
SEPTIC TANK

maximum (alarm condition). DRAIN PIPE

MEDIA FILTER PUMP


Pump Section:
• 120 Volt Models - 120 VAC, 60 Hz, single phase, 0-20 FLA (dose
chamber), 0-13 FLA (media filter). DOSE CHAMBER

• 230 Volt Models - 230 VAC, 60 Hz, single phase, 0-20 FLA (dose DOSE CHAMBER PUMP SK2205
chamber and media filter).
Typical Single Pass Media Filter
STANDARD FEATURES
• UL Labeled - entire control system (panel and switches) meets and/ 20/80 SPLITTER

or exceeds industry safety standards.


• Complete Package - package includes the low level cutout, timer 20% TO DRAIN
FIELD SYSTEM

override and high water alarm variable level float switches for the 80% RECIRCULATION TO PUMP
dose chamber, also the on/off and high water alarm switches for TANK OR 2ND COMPARTMENT
OF TWO CHAMBER SEPTIC TANK

the media filter. INLET PIPE


EFFLUENT FROM
• Installation Instructions - complete step-by-step instructions allow SEPTIC TANK
DRAIN PIPE

for easy installation.


MEDIA FILTER PUMP
• Lockable Latch - Added security and protection for your system.
• Two-Year Limited Warranty - our commitment to customer satisfaction.
• Redundant off circuit (redundant off float sold separately) - protection
DOSE CHAMBER

against primary switch failure. DOSE CHAMBER PUMP


SK2204

• Elapsed Time Meter for Media Filter Pump - allows monitoring of


hours run. Typical Recirculating Media Filter

SEQUENCE OF OPERATIONS FOR DUAL PUMP TIMED DOSE


Dual pump Timed Dose Panels control both dose chamber and media 5. The audible high water horn can be silenced by flipping the alarm
filter pumps. Both pumps operate independently except as noted. silence switch. The horn silence relay automatically resets the
1. Operation can begin after the following: alarm after the high water condition has been resolved.
• Correct voltage is supplied to the panel. 6. The three float system adds a “Timer Override” float. The “Timer
• A good ground is supplied to the panel. Override” float gives you the option of pumping from the basin
• Pumps are connected correctly to panel or starter pak. while the timer is in the “Off” cycle. It is only intended for times of
• Panel circuit breakers are closed. abnormally high liquid level inrushes. The normal operating level
• Floats are installed properly. should be between the “Low Level Cutout” float and the “Timer
• Pump HOA Switches are set to “Auto”. Override” float.
Dose Chamber System: 7. A four float system includes a “Redundant Off” float, a “Low
The dose chamber circuit will work with two, three, or four float Level Cutout” float, a “Timer Override” float and a “High Level
combinations. Alarm” float. The “Redundant Off” float is positioned slightly below
2. In a two float system, one float in the tank is the “Low Level the “Low Level Cutout” float, but above the pump. The normal
Cutout” float while the other is a “High Level Alarm” float. The operating level should be between the “Low Level Cutout” position
normal operating level should be between the “Low Level Cutout” and the “Timer Override” position. The “Redundant Off” and the
position and the “High Level Alarm” position. “Low Level Cutout” float switches must be closed for the pump
3. The control panel begins timing the “Off” sequence when the to operate on the timer.
“Low Level Cutout” float is activated. Once the timer completes Media Filter System:
the “Off” sequence, the timer will start the pump and continue 1. Operation can begin after the following:
to run until the programmed “On” sequence is completed. At STEP 1 in the dose chamber system has been completed.
this point the “Off” sequence begins timing again and the cycle 2. A media filter system requires two floats: The media filter pump
repeats.
“On/Off” float and the media filter “High Level Alarm” float. The
4. In the event the liquid level continues to rise, the “Alarm” float “High Level Alarm” float activates the audio/visual alarm and
switch will be closed. When the “Alarm” float switch is closed, the stops the dose chamber pump from dosing the media filter.
following will occur: 3. A circuit is provided to install a “Redundant Off” float in the media
• The external high water light will illuminate.
• The audible high water horn will sound. filter if required.