WORK
PROCEDURE No.:
BPCL-VCS-TPPL-PJPL-299-ML-08
PROPOSED
ARC-STRIKE REPAIR
WORK PROCEDURE
FOR
ARC-STRIKE REPAIR
WORK PROCEDURE No.:
BPCL-VCS-TPPL-PJPL-299-ML-08
TPPL: Tolani Projects Pvt Ltd.
BPCL: Bharat Petroleum Corporation Limited
VCS: VCS QUALITY SERVICES PVT. LTD.
WP: WORK PROCEDURE
ML : MAINLINE
PREPARED BY CHECKED BY
REV APPROVED BY VCS
TPPL TPPL
00 SIGNATURE
NAME
DATE
INDEX
1.0PURPOSE
2.0SCOPE
3.0 REFERENCE
4.0 MATERIALS
5.0METHODOLOGY
6.0QA/QC
7.0HEALTH, SAFETY&ENVIRONMENT
8.0DOCUMENTATION
1. PURPOSE
The purpose of this procedure is to lay guidelines and requirements and establish a
method or a system to control the arc strike repair activity and inspection to be used in
the LAYING OF ATF PIPELINE FROM BPCL PIYALA TERMINAL TO JEWAR INTERNATIONAL AIRPORT
(14” x 32 Kms).
2. SCOPE
This procedure covers the work method for repairing of AccidentalArc Strike/
Arc Burns on Pipescaused by electrode tip, electrode holder, welding cable,
earthling clamp etc coming in direct contactwith the pipe.
3. REFERENCE
Followingdocumentsintotalityorinpartshallformthereferencedocuments:
• Specification Welding and NDT of Pipelines - IND-SS-00-PL-SPC-
00022, Rev 0
• GasTransmissionAndDistributionPipingSystemASMEB31.8,Rev-01
• StandardforweldingofpipelinesandrelatedFacilities-API1104
• DesignandConstructionRequirementsForCrossCountryHydrocarbon
• PipelinesOISD141
4. MATERIALS
• GrindingMachine
• ThicknessGauge/ D-meter
• DPTKit
• MPTKit(Ifrequired)
• UT Machine
DOCUMENT NO. REV. SHT.
ARC-STRIKE REPAIR
BPCL-VCS-TPPL-PJPL-299-ML-08 00 3 of 5
Tolani Projects Private Ltd. WORK
PROCEDURE No.:
BPCL-VCS-TPPL-PJPL-299-ML-08
PROPOSED
ARK-STRIKE REPAIR
5. METHODOLOGY
Every effort must be made to avoid arc strike on the pipe wall outside the weld bevel.
Accidental arc burns shall be removed as follows:
The arc burns shall be carefully removed by filling / grinding and grinding and merging
with adjoining surface so as to avoid notches and stress concentration. A blackened spot is
evidence of a metallurgical notch and indicates that additional grinding is necessary. After
complete removal of Arc Burn, LPT shall be carried out and then the thickness shall be
measured by using calibrated ultrasonicthickness gauge (D Meter).
Repair by welding of arc burn on parent metal is not permitted. The visual inspection shall
be interpreted in accordance with API-1104 . If the thickness is found to be lower than the
acceptable limit, then the pipe will be cut out as a cylinder up to the affected area and a
fresh bevel shall be prepared as per the approved procedure and reports to be generated. In
case of doubtful cracks
UT & RT shall be carried out on such areas and reports will be generated for same. Reports
to be generated for Arc Burns or Arc Strikes and the dents will be removed by cutting of
damaged portion of the pipe as a cylinder and to be re- beveled as per the approved
procedure. The completed weld shall be carefully brushed and cleaned and shall appear
free from spatters, scales etc.
6.0 QUALITYCONTROLANDQUALITYASSURANCE
QualityAssuranceshallbemaintainedbyensuringthesystematicimplementationof
thisprocedure and ensure that necessary quality records are generated as
appended to thisprocedure.
8.0 DOCUMENTATION
Note:In case of any conflict between this approved procedure and contracts
specification ,the later shall govern.
EPMC Revision 00
VCS QUALITY SERVICES PVT. LTD.
Date :
Contractor Tolani Projects Pvt Ltd.
Verification
Sr. No. Activity Description Inspection By TPPL Remarks
byVCS/
2 Cleaning / Grinding WC S
4 PT / MT Test WC RM
5 UT WC W
6 RT If Required WC W
Legend: R : Review of Contractors Documents
HP : Hold Point S : Surveillance Inspection (10% Witness)
W : Witness A : Approval
RM : Random Monitoring
00 For Review
&Approval
Dwell Time :
Face Temperature :
Cleaner :
Penetrant :
Develapor :
Sign : Sign :
Name : Name :
Date : Date :